| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | HBW Series |
| Pricing | Upon Request |
| Accuracy Class | A (±0.1 °C), B (±0.2 °C to ±0.3 °C) |
| Measurement Range | HBW-1: −50 °C to +50 °C |
| HBW-2 | −50 °C to +80 °C |
| Sensor Element | IEC 60751-compliant Pt100 (α = 0.00385 Ω/Ω/°C) |
| Configuration | 4-wire RTD |
| Cable | Shielded 4-core, standard 10 m (custom lengths available) |
| Probe Dimensions | 70 mm sheath length, 4 mm sensing tip diameter, 10 mm sheath OD |
| Mass | 0.35 kg (including 10 m cable) |
| Calibration Interval | 2 years |
| Compliance | IEC 60751:2022, EN 60751, ASTM E1137/E1137M |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HD-2000 |
| Price | USD 1,240 (FOB) |
| Measurement Range | 0.01–100 µGy/h |
| Energy Threshold | 60 keV |
| Linearity (r vs. CPS) | ≥0.999 |
| Stability | ≤6% |
| Accuracy | ±20% |
| Sensitivity | ≥350 cps at 1 µGy/h |
| Power Consumption | ≤100 mW |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% @ 40 °C |
| Weight | 6 kg |
| Dimensions | 35 × 20 × 25 cm |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZLS-23B / ZLS-24C |
| Minimum Detectable Leak Rate | 2 × 10⁻¹¹ Pa·m³/s |
| Pump Type | Oil-Diffusion Vacuum System |
| Detection Gas | Helium (⁴He⁺) |
| Mass Separation Principle | Magnetic Sector Mass Filter |
| Key | Output Power ≥ 40 mW |
|---|---|
| Mode | Multimode |
| Operating Voltage | 3.5–4 kV |
| Operating Current | 15 mA |
| Wavelength | 632.8 nm |
| Origin | Tianjin, China |
| Manufacturer Type | Distributor |
| Domestic Product | Yes |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HFM-201 |
| Pricing | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | HG-01 |
| Pricing | Upon Request |
| Key Features | Temperature Range: RT +10 °C to 300 °C (customizable up to 500 °C) |
|---|---|
| Internal Dimensions | 500 × 600 × 500 mm (W×H×D) |
| External Dimensions | 700 × 1200 × 700 mm (W×H×D) |
| Temperature Uniformity | ±1.5 °C |
| Control Accuracy | ±0.5 °C |
| Heating System | Dual independent 2 kW nickel-chromium far-infrared heaters |
| Sensor | PT100 platinum resistance thermometer |
| Controller | LED digital or optional high-resolution touchscreen microprocessor controller with programmable timer (0–999 min) |
| Air Circulation | Forced convection via bottom-mounted centrifugal blower with left-side lateral airflow duct |
| Construction | Interior—SUS#304 stainless steel |
| Standard Accessories | Two adjustable stainless steel wire shelves |
| Power Supply | AC 220 V ±5 % / 50 Hz or AC 380 V ±5 % / 50 Hz |
| Total Rated Power | 4 kW (dual heater configuration) |
| Safety Protections | Over-temperature alarm, over-temperature cut-off, earth leakage protection |
| Compliance | Designed and validated per GB/T 2423.2–2022 (“Environmental testing — Part 2: Tests — Test B: Dry heat”) |
| Key | Temperature Range: +100 °C to +132 °C (saturated steam temperature) |
|---|---|
| Humidity Range | 75–100% RH (steam-saturated) |
| Operating Pressure | 1.5–3.2 kg/cm² (absolute) |
| Vessel Design Pressure | 4.0 kg/cm² |
| Time Setting Range | 000–999 hours |
| Pressurization Time | ~45 min to reach 1.04 kg/cm² |
| Temperature Uniformity | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Pressure Uniformity | ±0.2 kg/cm² |
| Chamber Dimensions | Ø300 mm × L500 mm (cylindrical) |
| Inner Vessel Material | SUS316 stainless steel, 3 mm thick |
| Outer Shell Material | SUS316 stainless steel, 1 mm thick |
| Insulation | Rockwool + rigid polyurethane foam |
| Heating Element | Finned seamless steel tube heater with platinum-coated surface |
| Control System | Taiwan-made microprocessor-based PID controller with PT100 sensor, LED time display, analog pressure gauge, auto-water replenishment valve |
| Safety Features | Dual-circuit high-temp electromagnetic safety valve, overpressure/overtemperature cut-off, manual & emergency pressure release, interlocked pressure-retention door |
| Key Features | 7-inch TFT color LCD touch controller with English/Chinese interface |
|---|---|
| Temperature range options | 0–150°C, −20–150°C, or −40–150°C |
| Humidity range | 20–98% RH |
| Temp. uniformity | ±2°C |
| Humidity uniformity | ±3.0% RH |
| Temp. fluctuation | ±0.5°C |
| Humidity fluctuation | ±2.5% RH |
| Heating rate | ~4.0°C/min |
| Cooling rate | ~1.0°C/min |
| Insulation | Dual-layer (rigid polyurethane foam + fiberglass) |
| Interior | SUS#304 stainless steel |
| Exterior | Powder-coated galvanized steel or optional SUS#304 |
| Refrigeration system | Hermetic compressor (French/Tecumseh) with R404A/R23 eco-friendly refrigerants |
| Humidification | Immersion-type nickel-chromium heating element |
| Data logging | 250 programs / 12,500 segments |
| Connectivity | Standard USB & RS-232 |
| Power supply | AC220V±5% / 50Hz (single-phase three-wire) or AC380V±5% / 50Hz (three-phase five-wire) |
| Key Specifications | Internal Chamber Dimensions (W×D×H): 3000 mm × 1000 mm × 2000 mm |
|---|---|
| External Dimensions (W×D×H) | ~3800 mm × 1300 mm × 2450 mm |
| Temperature Range | −40 °C to +130 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temp. Uniformity | ±2 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.5 %RH |
| Heating Method | Nickel-Chromium Alloy Resistive Heaters with PID+SSR Control |
| Humidification | Stainless Steel Steam Generator with Integrated Pure Water System |
| Dehumidification | Surface Cooling via Refrigerated Coil |
| Cooling Method | Water-Cooled Mechanical Refrigeration (R404A/R23/R22) |
| Required Cooling Water | ≤30 °C, 0.1–0.3 MPa, ~12 m³/h |
| Power Supply | 380 V ±10 %, 50/60 Hz, ~30 kVA |
| Air Circulation | Extended-Shaft Centrifugal Blower with External Motor |
| Compliance | Designed for ISO 17025-aligned environmental testing labs |
| Key Features | Temperature Range: RT+10°C to 300°C |
|---|---|
| Internal Dimensions | 450 × 400 × 400 mm (W×H×D) |
| External Dimensions | 650 × 900 × 600 mm (W×H×D) |
| Temperature Uniformity | ±1.5°C |
| Control Accuracy | ±0.5°C |
| Heating System | Dual independent 2 kW nickel-chromium far-infrared heaters |
| Sensor | PT100 platinum resistance thermometer |
| Air Circulation | Forced convection via bottom-mounted centrifugal blower with left-side lateral airflow duct |
| Timer Range | 0–999 minutes |
| Power Supply | AC220V ±5%, 50 Hz, 2000 W |
| Safety Protections | Over-temperature alarm, thermal cutoff, earth leakage protection |
| Construction | Inner chamber – SUS#304 stainless steel |
| Standard Accessories | 3 adjustable stainless steel wire shelves |
| Compliance | GB/T 2423.2, IEC 60068-2-2, ASTM D3045, ISO 188 |
| (Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJ211B |
| Instrument Type | Electromechanical Universal Testing Machine |
| Max Test Load | 30 kN |
| Load Range | 0–30 kN (fully adjustable) |
| Load Accuracy | ±1% FS or ±0.5% FS |
| Crosshead Travel | 420 mm |
| Displacement Resolution | ±0.5% of reading |
| Temperature Range | −70 °C to +350 °C (isothermal hold capability at 350 °C) |
| Heating/Cooling Rate | ≥5 °C/min |
| Temperature Controller Resolution | 0.1 °C |
| Test Speed Range | 0.001–500 mm/min (optional extension to 1000 mm/min) |
| Speed Accuracy | ±0.5% |
| Displacement Measurement Accuracy | ±0.5% |
| Strain Measurement Accuracy | ±0.5% |
| Safety Features | Electronic end-limit protection, emergency stop button |
| Machine Weight | 135 kg) |
| Key | Temperature Range: RT+10°C to 300°C (customizable up to 500°C) |
|---|---|
| Internal Dimensions (OK-T-72) | 450×400×400 mm (W×H×D) |
| Internal Dimensions (OK-T-150) | 500×600×500 mm (W×H×D) |
| External Dimensions (OK-T-72) | 650×900×600 mm (W×H×D) |
| External Dimensions (OK-T-150) | 700×1200×700 mm (W×H×D) |
| Temperature Uniformity | ±1.5°C |
| Control Accuracy | ±0.5°C |
| Heating System | Dual independent 2 kW far-infrared Ni-Cr alloy heaters |
| Sensor | PT100 platinum resistance thermometer |
| Controller | Microprocessor-based digital touchscreen controller with timer (0–999 min) |
| Power Supply | AC220V±5% / 50 Hz or AC380V±5% / 50 Hz |
| Total Rated Power | 2000 W (OK-T-72), 4500 W (OK-T-150) |
| Construction | Interior – SUS#304 stainless steel |
| Standard Accessories | 2–3 adjustable stainless steel wire shelves |
| Safety Features | Leakage current protection, over-temperature alarm and cutoff, thermal fuse backup |
| Compliance | Designed per GB/T 2423.2 (IEC 60068-2-2) for high-temperature environmental testing |
| Key Features | Temperature Range: +5°C to 55°C |
|---|---|
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL/80 cm²·h |
| Spray Modes | Continuous or Cyclic |
| Test Timing | 1–999 sec/min/hr (adjustable) |
| Chamber Construction | 6 mm PVC-coated chamber walls (heat-resistant to 80°C), SUS#304 stainless steel saturated air tank, transparent acrylic impact-resistant lid |
| Air Supply System | Two-stage pressure regulation (1 kg/cm²), integrated particulate filtration |
| Sample Rack | Adjustable flat-angle fixture (15°/30°), multi-directional fog exposure |
| Compliance | Designed per CNS, JIS Z 2371, ASTM B117 (NSS), ASTM G85 Annex A2 (CASS) |
| Models | OK-FH-150B / OK-FH-250B / OK-FH-750B |
| Power Consumption | 1.3 kW / 1.5 kW / 1.8 kW |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HKCube 1 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HKCube Range 1 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HKiPORT CL-GigE |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Operating Temperature | -40°C to +60°C |
| Interface Compatibility | Camera Link Base (26-pin MDR), GigE Vision v2.0 compliant |
| Power Delivery | PoCL (Power over Camera Link) support |
| GPIO | 4-channel opto-isolated digital I/O |
| Form Factor | External ruggedized enclosure (industrial grade) |
| SDK | eBUS SDK v5.3+ (Windows/Linux x64, C/C++, .NET, Python bindings) |
| Certification | CE, FCC Class A, RoHS compliant |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HMI-60 |
| Pricing | Upon Request |
| Inoculation Time | 9 or 13 s |
| Weight | 12 kg |
| Power Consumption | 120 W |
| Dimensions (L×W×H) | 335 × 250 × 415 mm |
| Inoculum Volume | 5 µL (24-position mode), 1 µL (60- and 96-position modes) |
| Petri Dish Compatibility | 90 mm diameter |
| Input Voltage | 220 V AC |
| Inoculation Pin Diameter | 3.0 mm (24-pin configuration), 1.6 mm (60-/96-pin configurations) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1700 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Scanning |
| X-ray Tube Power | Not Applicable (Rh anode, max 50 kV / 1 mA) |
| Elemental Range | Na to U |
| Detection Limits | Cd ≤ 2 ppm, Pb ≤ 5 ppm, Cl ≤ 50 ppm |
| Sample Chamber Max Size | 460 × 360 × 150 mm |
| X-ray Beam Diameters | Φ1.2 mm and Φ3.0 mm (motorized switching) |
| Detector | High-Purity Silicon XEROPHY Detector |
| Liquid Nitrogen Capacity | 3 L |
| LN₂ Consumption | <1 L/day (only during operation) |
| Optical Magnification | 50× (coaxial with X-ray beam) |
| Software | Automated qualitative/quantitative analysis (fundamental parameters method, calibration curve method, single-point correction) |
| PC Requirements | Pentium IV ≥1.8 GHz, ≥1 GB RAM, ≥120 GB HDD, Windows XP, 17″ monitor, color inkjet printer |
| Ambient Temp | 10–35 °C (optimal), 5–40 °C (operational) |
| Humidity | ≤80% RH at 5–31 °C |
| Power Supply | AC 100/120/220/240 V ±10%, 50/60 Hz |
| Power Consumption | ≤1.3 kVA (system-wide) |
| Weight | ~265 kg (analysis unit only) |
| Dimensions | Analyzer Unit: 610(W) × 750(D) × 500(H) mm |
| Signal Processing Unit | 220(W) × 500(D) × 480(H) mm |
| Key | Max. Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Sweep Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max. Acceleration | 20 g |
| Vibration Axes | Vertical (Z) + Horizontal (X/Y) |
| Waveform | Sine |
| Programmable Segments | 1–15 segments, each with user-defined frequency & duration, loopable |
| Octave Sweep Modes | 5-step logarithmic (low→high, high→low, low→high→low, repeatable) |
| Power Rating | 2.2 kW |
| Table Dimensions (L×W) | 500×500 mm (customizable) |
| Unit Dimensions (L×H×W) | Vertical unit: 500×200×500 mm |
| Horizontal unit | 500×250×500 mm |
| Input Voltage | 1φ AC 220 V, 50/60 Hz |
| Max. Current | 6 A |
| Frequency Resolution | 0.01 Hz, Accuracy: ±0.1 Hz |
| Table Mounting Pattern | Customizable M6/M8 threaded holes |
| Optional Accessories | Magnesium alloy fixtures, FEM-optimized fixtures, circular/square/octagonal extension tables, thermal isolation pads for environmental chamber integration |
| Origin | China |
|---|---|
| Type | Portable |
| Measurement Range | 60–140 dB (re 10⁻⁶ m/s²) |
| Frequency Range | 1–80 Hz |
| Frequency Weightings | Whole-body vertical (VLz), whole-body horizontal (VLx-y), linear (VAL) |
| Dimensions (main unit) | 24 × 8.1 × 3.1 cm |
| Weight (main unit) | 0.4 kg |
| Data Storage Capacity | 127 measurement sets |
| Compliance | ISO 2631-1, ISO 5349-1, and IEC 61260 Class 2 requirements for vibration meters |
| Origin | China |
|---|---|
| Manufacturer Type | Distributor |
| Model | HS6288B |
| Price | USD 1,390 (FOB) |
| Frequency Range | 31.5 Hz – 8 kHz |
| Sound Pressure Level Range | 35–130 dB(A), 40–130 dB (Linear) |
| Self-Noise | <20 dB(A) |
| Time Weighting | Fast (F), Slow (S), Max Hold |
| Measurement Functions | Leq, LAE, LN (L10/L50/L90), Lmin, Lmax, SD, Ld, Ln, Ldn |
| Measurement Durations | Manual trigger, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 8 h, 24 h, and full-hour synchronized logging |
| Display | 54 × 42 mm LCD with analog bar graph, real-time time stamp, measurement mode indicator, and 1/1-octave center frequency readout |
| Interface | RS-232 serial port for PC connectivity and data export |
| Standard Accessories | HS6288B(D) main unit, 4784A thermal printer (with charger), mounting bracket, software CD, thermal paper roll, 18″ protective carrying case, windscreen, screwdriver |
| Optional Accessories | 5 m / 10 m extension cables, Class 1 acoustic calibrator (e.g., HS6020) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HSA |
| Pricing | Available Upon Request |
| Max Heating Temperature | 230 °C ±0.3% |
| Bidirectional Measurement | MD & CD |
| Thermal Expansion Range | up to 27% |
| Thermal Shrinkage Range | up to 5% |
| Sample Dimensions | 60 mm × 200 mm (MD or CD) |
| Resolution | 0.013% |
| Power Supply | 220 V / 50 Hz |
| Dimensions (H×W×D) | 295 mm × 280 mm × 320 mm |
| Weight | 15 kg |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HSS-1B |
| Quotation | Upon Request |
| Temperature Control Range | Room Temp +10°C to 100°C |
| Temperature Stability | ±0.03°C |
| Heating Power | 1 kW |
| Circulation Pump Flow Rate | 6 L/min |
| Bath Tank Dimensions (L×W×H) | 330 × 200 × 180 mm |
| Bath Opening Dimensions | 190 × 160 mm |
| External Dimensions | 385 × 250 × 380 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Bath Tank Material | Stainless Steel (304) |
| Bath Volume | 12 L |
| Analgesia Chamber Diameter | φ160 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HT200 |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HVE |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HY-3000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Repeatability | <1% |
| Response Time | 30 s |
| Measured Gases | CO, CO₂, CH₄, O₂ |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-766B |
| Pricing | Available Upon Request |
| Roller Diameter | 150.0 ± 0.2 mm |
| Roller Length | ~500 mm |
| Lateral Traverse per Revolution | 4.2 ± 0.04 mm |
| Test Loads | 2.0 ± 0.1 N, 5.0 ± 0.1 N, 10.0 ± 0.2 N |
| Roller Speed | 40 ± 1 rpm (adjustable) |
| Abrasion Distance | 20.0 ± 0.1 m or 40.0 ± 0.2 m (digitally preset) |
| Display | LCD Controller |
| Sample Rotation Mode | Selectable (Self-Rotating / Non-Self-Rotating) |
| Specimen Holder ID Range | 15.5–16.3 mm (adjustable), Projection Height: 2.0 ± 0.2 mm |
| Holder Axis Tilt | 3° from vertical |
| Holder-to-Roller Axial Offset | ±1 mm |
| Arm Stability | Vibration-free during operation |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-7721C |
| Price | USD 1,760 (FOB Tianjin) |
| Standard Compliance | GB/T 6670–2008, ASTM D3574, ISO 8307 |
| Drop Height (Method A) | 500 ± 0.5 mm |
| Drop Height (Method B) | 460 ± 0.5 mm |
| Ball Mass (Method A) | 16.8 ± 1.5 g |
| Ball Mass (Method B) | 16.3 g |
| Ball Diameter | 16.0 ± 0.5 mm |
| Sample Dimensions | 100 × 100 × 50 mm (L × W × H) |
| Rebound Accuracy | < ±1.5% |
| Measurement Output | Average rebound height, average rebound percentage, statistical summary per test set |
| Control System | Industrial PLC + 7-inch TFT touch HMI (Chinese UI) |
| Data Output | Integrated thermal micro-printer (desktop type) |
| Sensor | High-speed optical distance sensor (non-contact, 1 kHz sampling) |