| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | SX-10-12 |
| Rated Temperature | 1200 °C |
| Power Supply | 380 V AC, 10 kW |
| Internal Chamber Dimensions | 400 × 250 × 160 mm (W × D × H) |
| Heating Element | Kanthal A1 or Equivalent High-Temp Alloy Wire |
| Insulation | Refractory Ceramic Fiber + Firebrick Lining |
| Compliance | Meets General Requirements of GB/T 10066.1–2004 & ASTM E1142–22 for Laboratory Furnaces |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SX-2.5-10 |
| Rated Voltage/Power | 220 V / 2500 W |
| Chamber Dimensions | 200 × 120 × 80 mm (L×W×H) |
| Maximum Operating Temperature | 1000 °C |
| Heating Element | Embedded Resistance Wire (Ni-Cr Alloy) |
| Insulation | High-Density Ceramic Fiber Board |
| Door Mechanism | Counterweighted Lever-Latch System |
| Compliance | CE-marked per IEC 61000-6-3 & IEC 61000-6-4 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SXT-02 |
| Price | Upon Request |
| Sample Capacity | 2 units per batch |
| Extraction Flask Volume | 500 mL per flask |
| Sample Mass Range | 0.5–20 g per flask |
| Temperature Control Range | +5 °C above ambient to 100 °C |
| Heating Power | 300 W |
| Dimensions (W×D×H) | 750 × 360 × 550 mm |
| Net Weight | 16 kg |
| Solvent Recovery | Automated |
| Timer with Audible Alert | Yes |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SXT-06 |
| Pricing | Available Upon Request |
| Sample Capacity | 6 positions |
| Extraction Flask Volume | 150 mL per position |
| Sample Weight Range | 0–5 g per position |
| Temperature Control Range | +5 °C above ambient to 100 °C |
| Heating Power | 300 W |
| Power Supply | 220 V ±10 V, 50 Hz |
| Dimensions (W×D×H) | 550 × 320 × 626 mm |
| Net Weight | 23 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SY-100 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SY-100 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SY-100 |
| Pricing | Available Upon Technical Consultation |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SY-100 |
| Pricing | Available Upon Request |
| (Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SY-100 |
| Pricing | Available Upon Request) |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SYD-2806H |
| Pricing | Upon Request |
| Key | Origin: Liaoning, China |
|---|---|
| Manufacturer Type | Distributor |
| Country of Origin | China |
| Model | SYJ-80QY |
| Price | Upon Request |
| Motor Power | 1600 W |
| Voltage/Frequency | AC 220 V / 50 Hz |
| Spindle Speed Range | 0–650 rpm |
| Standard Core Diameters | Ø32 mm, Ø45 mm |
| Max. Sampling Depth | 50 mm |
| Max. Sample Stage Size | 300 × 300 mm |
| Dimensions (L×W×H) | 500 × 512 × 750 mm |
| Cooling System | Integrated water-cooled feed |
| Operating Environment | ≤1000 m altitude, 10–40 °C ambient, 45–65 %RH |
| Water Supply | Required (inlet & drain) |
| Electrical Supply | AC 220 V / 50 Hz |
| Ventilation | Required |
| Footprint Requirement | 700 × 700 × 700 mm |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM Series |
| Pricing | Upon Request |
| Measurement Principle | Extractive Nephelometry (Scattered Light Detection) |
| Measurable Parameters | Mass Concentration of Ambient and Flue Gas Particulate Matter (PM₁₀, PM₂.₅, TSP) |
| Detection Limit | 0.1 µg/m³ (as PM₁₀ equivalent) |
| Sampling Method | Heated Extractive Probe with Return-Line Conditioning |
| Optical Maintenance | Purge-Gas–Assisted Lens Cleaning |
| Calibration | In-Situ Auto-Zero and Span Calibration via Patented Reference Path Technology |
| Compliance | Designed to meet EN 15267-3, EN 14181 (QAL1/QAL2), and EPA Method 9/PS-11 requirements for continuous emission monitoring systems (CEMS) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM-200 |
| Pricing | Upon Request |
| Measurement Principle | Beta-Ray Absorption with Complementary Optical Scattering |
| Measured Parameter | Total Suspended Particulate Mass Concentration (PM) |
| Detection Limit | 0.1 mg/m³ (100 µg/m³) |
| Compliance | Designed to meet EU Directive 75/76/EEC requirements and EPA Method 5 for isokinetic sampling |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SYQ-DSX-280B / YX-280A |
| Price | USD 225 (FOB Shanghai, ex. VAT & shipping) |
| Chamber Volume | 18 L |
| Power Supply | 220 V AC, 2 kW |
| Net Weight | 12 kg |
| External Dimensions | 420 × 420 × 600 mm |
| Maximum Operating Pressure | 0.142 MPa |
| Adjustable Sterilization Temperature Range | 105–126 °C |
| Sterilization Timer Range | 0–60 min |
| Heating Method | Electric Resistance |
| Safety Features | Automatic pressure-interlocked lid lock, dry-run prevention, auto cold-air purge, dual-scale Class II pressure gauge, spring-loaded safety valve & manual vent valve |
| Construction Material | Full 304 stainless steel chamber and housing |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ExoCounter |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | Ultra-Micro Nucleic Acid and Protein Analyzer |
| Sample Volume | 12.5 µL |
| Counting Speed | >200,000 events/sec |
| Throughput | 16 samples per 15 min (single disc) |
| Linear Detection Range | 1×10⁶ – 3×10⁸ particles/mL |
| Detection Principle | Digital immunoassay coupled with Blu-ray optical disc-based microfluidic separation and fluorescence counting |
| Dimensions (Analyzer) | 210 mm (W) × 297 mm (D) × 250 mm (H) |
| Dimensions (Washer Module) | 210 mm (W) × 330 mm (D) × 350 mm (H) |
| Software | Proprietary data acquisition and analysis suite with CSV export capability |
| Compliance | Designed for GLP-compliant workflows |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ExoCounter |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EC900 |
| Price Range | USD 7,000 – 14,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EC91 |
| Price | USD 9,400 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 911 |
| Price Range | USD $6,800 – $13,600 (FOB) |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Sensor Life | Typically 2–3 years (field-replaceable) |
| Enclosure Rating | NEMA 4X equivalent |
| Hazardous Area Certification | UL Class I, Div. II, Groups C & D |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | SZ700TR |
| Price | USD 2,200 (FOB Beijing) |
| Zoom Ratio | 8.8:1 (0.8×–7.0× Objective Zoom) |
| Standard Total Magnification Range | 8×–70× (with 10× Eyepieces) |
| Working Distance | 108 mm (standard), down to 35 mm with 2.0× Auxiliary Objective |
| Eyepiece | SWH10× (23 mm Field Number, High-Eye-Point, Widefield) |
| Interpupillary Adjustment | 52–76 mm (linked) |
| Diopter Compensation | ±6 D per eyepiece |
| Inclination | 35° Tilting Binocular/Triocular Tube |
| Rotation | 360° Swivel Head |
| Focusing Travel | 100 mm (vertical column) |
| Stage Diameter | Ø95 mm |
| Pillar Diameter | Ø25 mm |
| Center-to-Center Distance (Pillar to Bracket) | 140 mm |
| Bracket Mounting Diameter | Ø76 mm |
| Illumination Options | Adjustable 6 V / 10 W Halogen Reflector Lamp |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SZQ |
| Pricing | Available Upon Request |
| Wet Film Thickness Range | 25–500 µm |
| Thickness Accuracy | ±2 to ±10 µm (dependent on model) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T-Maze |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T11 |
| Price Range | USD 700 – 7,000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0–14 |
| mV Measurement Range | ±2000 mV |
| pH Resolution | 0.01 |
| mV Resolution | 0.1 mV |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±0.2 mV |
| Titration Accuracy | ±0.15% (10 mL), ±0.2% (20 mL) |
| Minimum Dispensing Volume | 10 µL |
| Stepper Motor Resolution | 1/60,000 steps |
| Temperature Interface | Pt1000 (Resolution: 0.1 °C, Max Error: ±0.2 °C) |
| Electrode Interfaces | 2 x indicator electrode, 2 x reference electrode, 2 x polarizable electrode |
| Color Sensor | 16-bit RGB tri-color sensor |
| Dimensions | 200 × 200 × 260 mm |
| Weight | 4.3 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T4 |
| Price | Upon Request |
| Cup Volume | 100 mL |
| Orifice Diameter | Φ4 mm |
| Temperature Range for Calibration | 25 ± 2 °C |
| Calibration Correction Factor | 0.97–1.03 |
| Max. Measurable Efflux Time | 150 s |
| Material | High-Purity Electrolytic Copper |
| Compliance | GB/T 1723–1993, ASTM D1200–2022, ISO 2431:2019 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T40 |
| Pricing | Available Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TA-10 |
| Pricing | Upon Request |
| Max Operating Temperature | 1000 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | <1% of reading |
| Heating Rate Control | 5 ± 1 °C/min (PID-regulated, fully automated) |
| Test Method | Fiber Draw Method (ASTM C336, SJT 11039–1996, JC/T 752–1996) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Variants | TA51, DA400, DA20 |
| Pricing | Upon Technical Consultation |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JM-IV |
| Pricing | Available Upon Request |
| Rotational Speed | 60 ± 2 rpm |
| Sample Holder Diameter | 100 mm × Thickness 8 mm × Height 3 mm |
| Standard Load Weights | 500 g, 750 g |
| Sandwheel Balancing Weights | 20 g (shaft-mounted), 20 g, 10 g, 5 g, 2 g, 1 g |
| Reference Glass Disc | 100 × 8 × 3 mm |
| Drive Motor | 25 W, 220 V, 4-pole |
| Abrasive Wheels | 50 × 12 mm, Grade 100 & 120 |
| Counter Display | 4-digit LED (0–9999) |
| Wheel Truing Motor | 40 W, 220 V, 2850 rpm |
| Vacuum System | VW-80G, Adjustable Airflow |
| Main Unit Dimensions (L×W×H) | 360 × 240 × 220 mm |
| Truing Unit Dimensions | 300 × 180 × 180 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q Series |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Flow Rate | 0.005–100 mL/min |
| Maximum Discharge Pressure | 3.0 MPa |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TACT-2 |
| Price | Upon Request |
| Control Range | −100 to +400 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| AC Input | 110–230 V AC |
| Max AC Output (Resistive Load) | 700 W |
| DC Output | 12 V DC, 2 A max (TACT-2LV & TACT-2DF only) |
| Dual Setpoint Safety Limit | 40 °C (TACT-2LV & TACT-2DF only) |
| Dimensions (W × H × D) | 18.4 × 11.1 × 25.4 cm |
| Weight | <2.27 kg |
| Ground Leakage Current | <1 mA at 110 V AC |