Generic
Filter
Showing 811–840 of 1032 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LXQ Linear Ion Trap Mass Spectrometer |
| Price Range | USD 140,000 – 280,000 (FOB) |
| Instrument Type | Linear Ion Trap |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform |
| Compliance Standards | ASTM E1421, NIST-traceable, USP <1119>, EP 2.2.24, JP 2.07, FDA 21 CFR Part 11 (with ValPro™ and OMNIC Security Suite) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Thermo Scientific SampleManager LIMS |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Nuova Series |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSQ Quantum GC |
| Price Range | USD 135,000 – 205,000 (FOB) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Standalone GC-Coupled System |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI), switchable without venting |
| Collision Cell | Zero-Crosstalk RF-Only Quadrupole Collision Cell |
| Acquisition Modes | High-Selectivity SRM (H-SRM), Quantitative Enhanced Data-dependent MS/MS (QED-MS/MS) |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 audit trail, electronic signature, and data integrity requirements |
| Optional Inlets | PPINICI Pulsed Positive/Negative Ion Chemical Ionization Source, DEP/DIP Solid Probe Inlet |
| Flow Control | Digital Mass Flow Controller (MFC) for carrier and reagent gases |
| Key Features | Three-chamber design (hot, cold, test chambers) |
|---|---|
| Controller options | TEMI880 color touchscreen programmable temperature/humidity controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Protection functions | Compressor overheat/overcurrent/overpressure protection, heater dry-run prevention, chamber over-temperature alarm, low-water-level detection |
| Standard configuration | Double-glazed tempered observation window |
| Temperature/humidity control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating ambient | +5°C to +35°C |
| Heating | Nickel-chromium alloy wire heaters |
| Humidification | Surface evaporation type |
| Air circulation | Wide-band forced-air system (top discharge, bottom intake) |
| Cooling method | Air-cooled |
| Refrigeration | Original French “Tecumseh” hermetic compressors |
| Refrigeration circuit | Single- or dual-stage low-temperature loop design |
| Construction | Outer shell — SUS304B stainless steel |
| Airflow | Multi-wing centrifugal blower |
| Compliance | Designed to support ISO 16750-4, JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, and ASTM D4332 test protocols |
| Key | High-Temp Zone: +60 °C to +200 °C |
|---|---|
| Low-Temp Zone Options | −10 °C to −40 °C / −10 °C to −60 °C / −10 °C to −70 °C |
| Test Chamber Range | 0 °C to −40 °C / −10 °C to −55 °C / −10 °C to −65 °C |
| Temp. Fluctuation | ±0.5 °C |
| Temp. Uniformity | ±3 °C |
| Temp. Recovery Time | 3–5 min |
| Heat-up Rate (HT Zone) | ~5 °C/min (avg.) |
| Cool-down Rate (LT Zone) | ~1.5 °C/min (avg.) |
| Dwell Time per Stage | ≥30 min |
| Transfer Time (Chamber-to-Chamber) | ≤15 s |
| Key Features | Three-zone design (high-temperature chamber, low-temperature chamber, test chamber) |
|---|---|
| Programmable memory | 100 test profiles, up to 9999 cycles, max 999 h 59 min per segment |
| Data logging | paperless real-time curve display and archival |
| Compliance | MIL-STD-202, IEC 60068-2-14, JIS C 60068-2-14 |
| Optional | LN₂ rapid-cooling module, RS-485/RS-232C communication interface, external temperature data logger |
| Safety | PLC-controlled fault detection, automatic emergency shutdown on power fluctuation, dual thermal overprotection |
| Key Features | Three-zone design (hot zone, cold zone, test zone) |
|---|---|
| Temperature Range | Hot Zone: +80°C to +200°C |
| Cold Zone | −10°C to −70°C |
| Test Zone Operating Range | −10°C to +150°C |
| Temperature Control Accuracy | ±2°C |
| Resolution | 0.1°C |
| Hot Zone Ramp Rate | ~60 min (from ambient to +150°C) |
| Cold Zone Ramp Rate | ~120 min (from ambient to −60°C) |
| Test Zone Recovery Time | ≤3 min (with standard 2 kg I.C. load) |
| Internal Dimensions (Test Zone) | 500 × 350 × 500 mm (W×H×D) |
| External Dimensions | Approx. 1600 × 2050 × 2220 mm (W×H×D) |
| Construction | SUS304 stainless steel interior |
| Exterior | High-tensile cold-rolled steel with solvent-free powder coating |
| Insulation | Fire-retardant PU foam + glass wool, 100 mm thick |
| Compliance | GB10592–1989, GB2423.1, GB2423.2, GJB150.3, GJB150.4, IEC 60068-2-14, MIL-STD-810G |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Range | THV-1000 |
| Temperature Range | -70°C to +100°C |
| Humidity Range | 30–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±2°C |
| Humidity Uniformity | ±2/−3% RH (≥75% RH) |
| Internal Dimensions | 1000 × 1000 × 1000 mm |
| Static Load Capacity | 50 kg |
| Air Velocity | 1.0–3.0 m/s (VFD-controlled) |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Total Power | 36 kW |
| Compliance Standards | GB 10586–1989, GB 10592–1989, GJB 150.16–1986 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 106 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD3500 |
| Instrument Class | Radiation Dose Meter |
| Instrument Form Factor | Portable |
| Detectable Radiation Types | Photons (E > 5 keV), Neutrons (thermal–100 MeV), Beta particles (E > 70 keV) |
| Measurement Quantities | Photon dose, neutron fluence, beta dose |
| Dose Range | 10 μGy – 1 Gy (linear response) |
| Sensitivity Threshold | < 1 kGy |
| Temperature Range | 15 °C – 600 °C |
| Heating Rate | 1–50 °C/s |
| Temperature Stability | ±1 °C |
| System Stability | ±0.005% |
| Operating Ambient | 15–40 °C |
| Output Units | nC, gU, mrad, mrem, mGy, Gy, µSv, mSv, Sv |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micro One |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | Up to 6,000 rpm |
| Max RCF | 1,290 × g |
| Max Capacity | 2 mL × 8 (microtubes) or 0.2 mL × 16 (PCR strips) |
| Dimensions | 155 W × 175 D × 125 H mm |
| Power Supply | 230 V, 1 A, 50/60 Hz |
| Safety Certification | UL94V-0 compliant housing materials (PC, ABS, NBR) |
| Drive System | Direct-drive motor with dynamic deceleration |
| Acceleration Time | ≤5 s to 90% of set speed |
| Deceleration Time | ≤15 s (lid closed), ≤3 s (lid open) |
| Rotor Installation | Tool-free quick-lock mechanism |
| Compliance | Designed for GLP-compliant environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MicroOne |
| Pricing | Available Upon Request |
| Max Speed | 6200 rpm (±20%) |
| Rotor Capacity | 0.2 mL × 8-tube strip or 1.5–2.2 mL × 8 tubes |
| Max RCF | 1200–2910 × g |
| Temperature Range | Ambient |
| Acceleration Time | ≤5 s to ≥5000 rpm |
| Brake Time | 2 s (lid open), 10 s (lid closed) |
| Power Supply | 220 V, 50/60 Hz, Single-phase |
| Power Consumption | 153 W |
| Dimensions (W×D×H) | 123 mm × 173 mm × 153 mm |
| Vacuum Range | 0–0.1 MPa |
|---|---|
| Temperature Range | 30–150 °C (adjustable in 1 °C increments) |
| Temperature Uniformity | ±2 °C across working chamber |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Integrated Vacuum Pump Socket Rating | ≤220 V, 5 A |
| External Dimensions | 350 × 350 × 240 mm (L×W×H) |
| Manufacturer | Top Instrument (Tianjin, China) |
| Origin | China |
| Type | Benchtop Vacuum Drying Oven |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | LIMS Wizard |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP4300 / SP4305 |
| Quotation | Upon Request |
| Punching Speed Range | 0.01–0.70 mm/s |
| Maximum Stroke | 0–12 mm |
| Test Panel Width | 100 mm |
| Steel Panel Thickness | 0.8 mm |
| Aluminum Panel Thickness | 1.2 mm |
| Dimensions (D×W×H) | 450 × 350 × 600 mm |
| Net Weight | ~31 kg |
| Power Consumption | 80 W |
| Display Resolution | 193 × 64 pixels |
| Backlight | Blue LED |
| Stroke Accuracy | ±0.01 mm |
| Speed Accuracy | ±1% of set value |
| Safety Features | Emergency Stop Button, Audible Alarm |
| Control Interface | Rotary Push-button Navigation, Multilingual On-screen Menu |
| Integrated LED Illumination System | Adjustable Angle, Intensity, and Color Temperature for Optimized Contrast |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.2 °C (20–50 °C), ±0.5 °C (50–100 °C) |
| Oscillation Frequency | 275 ± 3 cycles/min |
| Oscillation Amplitude | 35 mm |
| Programmable Modes | Standard (20 min oscillation + 10 min rest @ 50 °C), Fast (5 min oscillation @ 75 °C), Custom (0–99 min oscillation/rest, 0–99 °C setpoint) |
| Sample Capacity | Eight 100 mL syringes or six 250 mL Erlenmeyer flasks |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 5%, 800 VA |
| Dimensions (W×D×H) | 500 × 350 × 385 mm |
| Weight | <25 kg |
| Display | Backlit LCD with real-time parameter feedback |
| Compliance | GB/T 17623–1998, DL 429.4–1991 |
| Origin | Germany |
|---|---|
| Type | Imported Instrument |
| Model | EFM 022 |
| Measurement Distance Ranges | 1 cm (0–8 kV), 2 cm (0–16 kV), 5 cm (0–40 kV), 10 cm (0–80 kV), 20 cm (0–160 kV) |
| Display | Dual-line LCD with backlight (top line: distance in cm |
| bottom line | field voltage in V) |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Dimensions | 122 × 70 × 26 mm |
| Weight | 130 g |
| Operating Mode | CPS (Charged Plate Sensor) compatible (optional external high-voltage converter and flat-plate charger required) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APS-3321 |
| Pricing | Available Upon Request |
| Key Features | Dual-chamber design (hot/cold) with pneumatic door switching |
|---|---|
| Temperature Range | Hot Zone RT to +200°C, Cold Zone RT to −70°C |
| Test Zone Range | +60°C to +150°C (heat shock), 0°C to −45/−55/−65°C (cold shock) |
| Temperature Uniformity | ±2.0°C |
| Temperature Control Accuracy | ±0.5°C |
| Recovery Time | <5 min |
| Preheating Time (RT→150°C) | ~30 min |
| Precooling Time (RT→−70°C) | ~85 min |
| Refrigeration System | Twin-stage cascade refrigeration using R404A/R23 |
| Construction | Interior – SUS#304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Optional Customization | Internal dimensions scalable per user requirements |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TYS-3672A |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Phosphate Online Monitor |
| Instrument Type | Phosphate (Orthophosphate) Analyzer |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 mg/L |
| Repeatability | ±2% of reading or full scale |
| Measurement Cycle | 5 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure Range | 0–345 kPa (0–50 psig) |
| Drain Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Sulfide Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric (with DMPD Oxalate Reagent) |
| Range | 0–5 ppm (customizable for higher ranges) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Measurement Wavelength | 650 nm |
| Reference Wavelength | 810 nm |
| Cycle Time | 15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Volume per Analysis | 30 mL |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/v, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Effluent Port | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted (hardware included) |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Amine Concentration and H₂S/CO₂ Acid Gas Online Analyzer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Cu Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Bathocuproine or Neocuproine Method) |
| Range | 0–10 ppm (Low), 0–20 ppm (High) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Cycle Time | 5–15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Waste Outlet | 3/4" NPT male, atmospheric discharge |
| Analog Output | 4–20 mA, user-configurable |
| Alarm Outputs | Programmable digital relays |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg |