| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JAR-2 |
| Pricing | Available Upon Request |
| Control System | Microprocessor-Based CPU Control |
| Cycle Start Delay | 1–999 minutes |
| Cycle Termination Time | 1–999 minutes |
| Maximum Cycle Count | 99 cycles |
| Key | Temperature Range: −40 °C to +150 °C (optional down to −120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G |
| Inner Chamber Material | SUS304 Stainless Steel |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Number of dissolution vessels | 7 |
|---|---|
| Rotational speed range | 25–250 rpm |
| Speed resolution | 1 rpm |
| Speed accuracy | ±2% |
| Water bath temperature range | Ambient +5°C to 60°C |
| Temperature control accuracy | ±0.1°C |
| Maximum cumulative timing | 99 h 59 min |
| Number of programmable sampling intervals | 10 |
| Maximum interval duration | 9 h 59 min |
| Auto power-on/off timer range | 99 h 59 min |
| Power consumption | 1300 W |
| Input voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 670 × 470 × 420 mm |
| Net weight | ~42 kg |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AVVOR 8000, AVVOR 9000, HM1000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-3 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Price | Upon Request |
| Measurement Range | 0–10 ppm |
| Method | EPA 4500-Cl G (DPD Colorimetric) |
| Resolution | 0.01 ppm (0–6 ppm), 0.1 ppm (6–10 ppm) |
| Accuracy | ±2% (0–6 ppm), ±10% (6–10 ppm) |
| Response Time | 3 seconds |
| Power Supply | 4 × AAA Alkaline Batteries |
| Certification | CE |
| Light Source | LED @ 515 nm |
| Sample Volume | 5 mL |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AVVOR 9000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | HM-1000, AVVOR-8000, AVVOR-9000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Price | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000-CODmn |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AWA5661 |
| Pricing | Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | AYAN-30L |
| Price | ¥45,500 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 30 L/min |
| Output Pressure Range | 0–0.6 MPa |
| Nitrogen Purity | 99.999% |
| Dew Point | −40 °C |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | OD-8 |
| Price Range | USD 35,000–57,000 |
| Automation Level | Fully Automatic |
| Channel Count | Multi-channel |
| Extraction Method | Column-Based SPE |
| Fluidic Materials in Contact | PharMed® and PTFE |
| Sample Throughput | Up to 24 textile specimens per run (8 primary channels + 3× parallel staging) |
| Flow Rate | 6 mL/min (adjustable range: 5–8 mL/min) |
| Total Elution Volume Capacity | 0–120 mL |
| Certified Compliance | Designed to meet all operational requirements of GB/T 17592–2006 “Textiles — Determination of Certain Azo Colorants” |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Range | Customizable Standard & OEM Models |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BCNX |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Measurement Principle | Beta Attenuation + Laser Scattering Hybrid Method |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, PM₁ |
| Measurement Ranges | 0–1000 µg/m³, 0–2000 µg/m³, 0–10 mg/m³, 0–20 mg/m³ (field-selectable) |
| Sampling Flow Rate | 16.7 L/min (standard), configurable up to 30 L/min |
| Detection Limit | ≤2 µg/m³ (PM₂.₅, 1-hour average, ISO 12103-1 A2 dust reference) |
| Flow Stability | ±2% over 24 h (at 25°C, 1 atm, with integrated mass flow controller) |
| Compliance | Designed per HJ 653–2013, HJ 93–2013, and GB 3095–2012 |
| supports audit-ready data logging per EPA 40 CFR Part 58 Appendix A & ISO/IEC 17025 | 2017 requirements |
| (Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX RD20OC2 |
| Pricing | Available Upon Request) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-AQ04 |
| Pricing | Available Upon Request |
| Measurement Range | 0.0–4.0 mg/m³ |
|---|---|
| Accuracy | ±10% |
| Sampling Cycle | < 1 min |
| Operating Voltage | 220 VAC |
| Power Consumption | 8 W |
| Operating Temperature | –25°C to +75°C |
| Operating Humidity | 5%–95% RH |
| Probe Dimensions | φ45 × 10 mm |
| Data Logger Dimensions | φ45 × 270 mm |
| Startup Time | ~20 s (network-dependent) |
| Controlled Load Rating | 2 kW / 250 V / 10 A per channel |
| Overcurrent Protection | Auto-disconnect after 6 s at threshold exceedance |
| Communication Interfaces | RS485 (sensor), Analog Inputs (status), TCP/IP, CDMA/GPRS/2G, WiFi, LoRa, NB-IoT |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Oil Mist Measurement Range | 0–30,000 µg/m³ |
| Accuracy | ±10% of reading (vs. reference gravimetric method) |
| Zero Drift | ≤±0.5 mg/m³ over 1 h |
| Relative Error vs. Reference Method | ≤±20% (per HJ 629–2011 & DB11/1488–2018) |
| Linearity Error | ≤10% |
| Insulation Resistance | ≥20 MΩ |
| Withstand Voltage | No arcing or dielectric breakdown at rated test voltage |
| Sampling Cycle | 60 s |
| Operating Voltage | 220 VAC ±10% |
| Power Consumption | 8 W |
| Operating Temperature | 0–70 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Probe Dimensions | Ø24 × 248 mm (installation bore: Ø25–26 mm) |
| PM Measurement | Optical scattering principle |
| Resolution | 1 µg/m³ |
| Range | 0–20 mg/m³ (configurable variants: 0–10 mg/m³ or 0–2000 mg/m³) |
| NMHC Measurement | Dual-mode selectable — Metal Oxide Semiconductor (MOS) or Photoionization Detector (PID) |
| Range | 0–30 ppm or 0–1000 ppm |
| Resolution | 0.1 ppm (PID), 1 ppm (MOS) |
| Control Outputs | 4-channel dry-contact relay interface for fan/purifier status monitoring and remote switching |
| Overcurrent Protection | Automatic cut-off after 6 s if load current exceeds threshold |
| Data Reporting Interval | User-configurable (1–3600 s) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Behr CL10 (AOX/EOX/POX) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.1–3000 mg/L Cl (as Cl⁻ equivalent) |
| Accuracy | <1% RSD |
| Repeatability | <1% RSD |
| Detection Limit | 0.1 µg Cl absolute |
| Resolution | 0.01 µg Cl |
| Carrier Gases | O₂ (99.95%), Ar (99.95% for EOX) |
| IR Furnace Max Temp | 1000 °C |
| Resistive Downstream Furnace Max Temp | 1000 °C |
| Sample Capacity | AOX—up to 200 mL aqueous |
| Analysis Time | 5–10 min per sample (halogen-content dependent) |
| Titration Current Range | 2–450 µA |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic (PRC) |
| Model | FJ-403GI |
| Pricing | Upon Request |
| Measurement Quantity | Personal Dose Equivalent Hp(10) |
| Dose Range | 0.01 µSv – 9999 mSv |
| Dose Rate Range | 0.1 µSv/h – 200 mSv/h |
| Communication Interface | Infrared (IR) Data Transfer |
| Power Supply | Two AA 1.5 V alkaline batteries or one 3.6 V high-energy lithium battery |
| Battery Life | Up to 1000 hours (at background radiation, 1.5 V) |
| Data Storage Capacity | 160 dose history records (time-stamped, auto-logged) |
| Alarm Functions | Configurable dose rate threshold, cumulative dose threshold, and incremental dose audio alert |
| Compliance | Calibrated to ICRP-defined Hp(10) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | Beilao-20 |
| Price | USD 570 (approx.) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BD2000 |
| Pricing | Available Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Genesis ALD |
| Substrate Width | Up to 420 mm |
| Process Temperature | Up to 250 °C |
| Precursor Channels | Configurable (standard ≥4) |
| ALD Film Thickness Range | Up to 100 nm |
| Dynamic Deposition Rate (Al₂O₃) | 10 nm·m/min |
| Uniformity | ≤±1.5% (3σ, across full web width) |
| System Footprint | Customizable per integration requirements |
| Weight | Site-specific (typically 1,200–2,500 kg) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1000IIA2 |
| Price | USD 4,200 (FOB) |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1200 × 780 × 1950 mm |
| Internal Work Area (L×W×H) | 1000 × 700 × 680 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm (EN 1822-1 |
| Inflow Velocity | 0.35 ± 0.025 m/s |
| Downflow Velocity (Center) | 0.26 ± 0.025 m/s |
| Downflow Velocity (Rear) | 0.27 ± 0.025 m/s |
| Side Airflow Velocity | 0.38 ± 0.025 m/s |
| Air Leakage Rate | ≤1×10⁻⁶ m/s @ 500 Pa |
| Sound Pressure Level | ≤62 dB(A) |
| Vibration Amplitude (Half-Peak) | ≤5 µm |
| Illumination | ≥300 lux |
| Power Supply | AC 220 V, 50 Hz, Single Phase |
| Power Consumption | 0.6 kW |
| Net Weight | <200 kg |
| HEPA Filter Size & Qty | 995 × 600 × 38 mm × 1 |
| Fluorescent Lamp / UV Lamp | 20 W × 1 / 20 W × 1 |