| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-130 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 25–500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Diameter | 130 mm |
| Sample Chamber Height | 200 mm |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | iso-BTC+ |
| Measurement Mode | Isothermal Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC-compatible architecture) |
| Temperature Range | −60 °C to +100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Dimensions | 350 × 350 mm (W × D) |
| Maximum Compensation Power | 200 W |
| Minimum Detectable Heat Flow | 5 mW |
| Brand | H.E.L |
|---|---|
| Model | PAC-02 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 20–350 °C |
| Temperature Resolution | 0.1 °C/min |
| Precision | ≤0.1 °C |
| Sample Chamber Volume | 2015 mL |
| Automation Level | Fully Automated |
| Origin | Fujian, China |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −40 °C to 500 °C |
| Temperature Resolution | 1 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | ~30 min |
| Heat Capacity | 10,500 J/K |
| Outer Bath Volume | ~20 L |
| Inner Bath Volume | 250 mL |
| Operating Modes | Adiabatic & Isothermal Calorimetry |
| Chamber Dimensions (Standard) | Φ35 × 35 cm or Φ50 × 50 cm |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | Up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Adiabatic Control Method | Real-time Online PhiTEC Calibration |
| Sample Chamber Dimensions | Φ50 × 50 cm (standard), Φ35 × 35 cm (optional) |
| Pressure Rating | Up to 30 MPa |
| Data Channels | Expandable to 8 or 16 independent temperature inputs |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | Phi-TEC I |
| Instrument Type | Adiabatic Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −60 °C to 500 °C |
| Temperature Resolution | 0.005 K |
| Temperature Accuracy (direct sample mode) | ±0.01 °C |
| Temperature Stability (isothermal mode) | ±0.001 °C |
| Heat Capacity | ~10,000 J/K |
| Sample Mass Range | 0.5–80 g |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Exothermic Detection Sensitivity | 0.005–0.2 °C/min |
| φ-factor (low-φ cell) | ≤1.05 |
| Stirring | Electromagnetic, 0–500 rpm (mechanical stirrer optional) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO |
| External/Inner Dewar Volume | 10 mL each |
| Single-Sample Test Duration | ~600 min |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phi-TEC II |
| Price Range | USD 135,000–270,000 (FOB UK) |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Temperature Accuracy (Direct Sample Mode) | ±0.001 °C |
| Temperature Tracking Rate | Up to 400 °C/min (Low-Φ mode) |
| Standard | 50 °C/min |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Tracking Rate | 0–200 bar/min (optional 700 bar/min) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Heat Release Detection Sensitivity | 0.002–0.2 °C/min |
| Sample Mass Capacity | 0.5–80 g |
| Adiabatic Correction Factor (Φ) | ≤1.05 (optimized for Phi-TEC II) |
| Outer & Inner Dewar Volume | 60 mL each |
| Thermal Capacity | 60,000 J |
| Single-Test Duration | Up to 1000 min |
| Stirring | Electromagnetic, 0–500 rpm (mechanical option available) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO (Isothermal) |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A, single-phase |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | TSu |
| Instrument Type | Accelerating Rate Calorimeter (ARC®-style) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | –60 °C to 500 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | ~600 min |
| Heat Capacity | ~10,000 J/K |
| Outer Dewar Volume | ~10 mL |
| Inner Dewar Volume | ~10 mL |
| Sample Mass Range | 0.5–5 g |
| Pressure Range (standard) | 0–200 bar |
| Sample Cell | 8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys) |