| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA |
| Mass Range | 1–200 amu (standard) |
| Response Time | ≤300 ms |
| Sample Pressure Range | 100 mbar – 2 bar (standard) |
| Detection Range | 1 ppm – 100% |
| Software | QGA Professional Quantitative Analysis Suite |
| Multi-Channel Capability | Up to 80 gas streams (with optional multi-port sampling valve) |
| External Signal Triggering | Yes |
| Data Integration | Supports external sensor inputs (e.g., temperature, pressure, CO analyzers) |
| Spectral Processing | Automated library matching, overlap subtraction, dynamic spectral simulation |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAPR0128 |
| Operating Pressure Range | Near-ambient (0.1–2 mbar typical for direct inlet |
| Detection Limit | Sub-ppm for most permanent gases and volatiles |
| Mass Range | 1–100 amu (standard), upgradable to 300 amu |
| Scan Speed | Up to 100 mass units per second |
| Data Output Formats | Raw ion current, % composition, ppm/v, nmol/s |
| Multi-stream Capability | Up to 80 gas streams via optional Hiden Multiplexing Valve System (HIDEN MVS-80) |
| Software | QGA Professional Edition with real-time quantification, spectral deconvolution, and external sensor integration |
| Compliance | Designed for GLP/GMP environments |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | qRGA |
| Mass Range | 1–200 amu |
| Ionization Mode | Threshold Ionization Mass Spectrometry (TIMS) |
| Electron Energy Resolution | 0.1 eV |
| Soft Ionization Range | 0–150 eV |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Detection Limit | ppm-level quantification |
| Shielding | Integrated radiation and magnetic shielding |
| Operational Mode | Dual-mode (conventional scanning + TIMS) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS |
| Vacuum Compatibility | Ultra-High Vacuum (UHV) |
| Ion Sources | IG20 Ion Gun (differential pumping), IFG200 FAB Source, Liquid Gallium Liquid Metal Ion Gun (LMIG) |
| Detection Limit | <1 ppb (for selected elements under optimized conditions) |
| Sample Manipulator | 4-Axis (X, Y, Z, θ) UHV-Compatible |
| Charge Neutralization | Electron Flood Gun |
| Cryogenic Capability | Integrated Liquid Nitrogen Cold Trap |
| Vacuum System | Bakeable UHV Chamber with RGA Monitoring |
| Mass Analyzer | Hiden EQS Quadrupole Mass Spectrometer |
| Control & Acquisition Software | MASsoft Operating System with ESM LabVIEW Interface and SIMS Imaging Module |
| Compliance | Designed for GLP/GMP-adjacent surface analysis workflows |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS Workstation |
| Mass Analyzer Type | Quadrupole |
| Primary Beam Energy | 25 keV Ga⁺ |
| Mass Range | 1000 amu |
| Mass Resolution | 0.5 amu (5% valley between adjacent equal-height peaks) |
| Detection Mode | Pulsed Ion Counting (positive/negative ions) |
| Dynamic Range | 7 decades |
| Spatial Resolution | 50 nm (Ga⁺ beam), 100–150 µm (O₂⁺/Cs⁺ beams) |
| Vacuum System | UHV-compatible, three-stage differential pumping |
| Control Interface | Ethernet LAN, RS232, RS485 |
| Software | MASsoft v6.x (GLP-compliant audit trail, method templating, automated sequence execution) |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | Spaci-MS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | SpaciMS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Application Domain | Catalytic Reactor Process Monitoring, Transient Gas Analysis, 3D Gas Composition Mapping |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | TGA-MS |
| Interface Type | Capillary Direct-Coupling Interface |
| Dead Volume | Minimized (< 10 µL) |
| Capillary Temperature Control | Up to 300 °C |
| Material of Construction | Inert (High-Purity Stainless Steel, SilcoNert®-treated Surfaces) |
| Gas Handling | Dual-Channel Mass Flow Controlled (H₂, He, N₂, Ar Compatible) |
| Flow Rate Range | 0.1–50 mL/min (Adjustable to Match TGA Effluent Profile) |
| Compliance | ASTM E2550, ISO 11358, USP <1210> |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XBS |
| Pricing | Upon Request |
| Ion Source | Crossed-beam, ±35° acceptance angle, 2 mm aperture |
| Detection Limit | 30 ions/s (for molecular beam studies) |
| Mass Range | 0–510 amu |
| Sensitivity | 100% down to 5 ppb |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Cooling | Integrated UHV-compatible water-cooled shield |
| Ionization | Tunable electron energy for soft ionization and appearance potential mass spectrometry |
| Signal Enhancement | RF-assisted primary filtering for improved high-mass transmission |
| Interface | RS232, RS485, Ethernet |
| Software | MASsoft™ for Windows® with automated mass list generation and real-time process control |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | XEMIS |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1 |
| Pore Size Measurement Range | < 50 nm |
| Temperature Range | 77 K to 773 K (–196 °C to 500 °C) |
| Pressure Range | Up to 200 bar |
| Analysis Theory | BJH, Langmuir, DFT, t-plot, α<sub>s</sub>-method |
| Balance Capacity | 5 g |
| Balance Resolution | 0.2 µg |
| Long-term Stability | ±5 µg |
| Dynamic Weighing Range | 0–200 mg |
| Construction | All-metal VCR-fitted architecture |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |