IONICON Analytik GmbH
Filter
Showing all 10 results
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BET |
| Pricing | Upon Request |
| Heating Temperature | 70 °C |
| Internal Volume | 40 mL |
| Response Time | < 100 ms |
| Sample Line Length | 2 m |
| Clinical Compliance | ISO/IEC 60601-1 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer | IONICON Analytik GmbH |
| Model | FUSION PTR-TOF 10k |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Source VOC Monitoring System |
| Detection Range | 100 ppqv – 100 ppb |
| Mass Resolution | ≥10,000–15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% of reading (mass axis calibration stability) |
| Response Time | ≤100 ms (90% signal rise time, T90) |
| Limit of Detection | <0.1 pptv (for selected VOCs, e.g., benzene, isoprene) |
| Sensitivity | up to 30,000 cps/ppbv (H₃O⁺ mode, for monoterpenes) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | LCU |
| Configuration Options | LCU-s (Standard), LCU-a (Advanced) |
| Dilution Range | ppt to % (v/v) |
| Output Flow Rate | 0.1–50 L/min (single gas stream) |
| Accuracy | <5% (relative) |
| Response Time | <1 min (for concentration step change, including calculation latency) |
| Humidity Control Range | 10–100% RH @ 40 °C |
| Evaporation Optimization | Dynamic temperature-controlled liquid dosing with real-time vapor pressure compensation |
| Condensation-Free Operation | Integrated heated transfer lines and isothermal vapor path |
| Dimensions (W×H×D) | 35 × 35 × 15 cm |
| Weight | 10 kg |
| Optional LCU-a Enhancements | Dual liquid inlet (second for humidity reference), additional gas inlet with Sulfinet™-coated mixing manifold |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Multi-Port Sampling Device |
| Valve Configurations | 2-way and 3-way |
| Port Options | 12-, 16-, 18-, or custom-configurable inlet ports |
| Material Options | PTFE- or PEEK-coated valve bodies |
| Application | Automated, sequential vapor/sampling stream selection for real-time analytical systems |
| Compliance | Designed for integration with PTR-MS, SIFT-MS, and other trace gas analyzers |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Nasal Sampling Probe |
| Compatibility | PTR-MS systems |
| Heated | Yes |
| Response Time | < 100 ms |
| Application | Real-time human nasal inhalation monitoring for VOC and odorant analysis |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR TOF 1000 ULTRA |
| Price | Upon Request |
| Pulse Frequency | ~150 kHz |
| Mass Resolution | >1500 m/Δm (FWHM) for m/z >60 |
| Response Time | <100 ms |
| Sensitivity | >2000 cps/ppbv at m/z 181 (standard) |
| Mass Range | 1–10,000 Da |
| Linear Dynamic Range | 5 pptv – 1000 ppbv |
| Inlet Flow Rate | 50–800 sccm |
| Inlet Heating Range | 40–180 °C |
| Drift Tube Heating Range | 40–120 °C |
| Power Supply | 100–230 V AC, max. 1500 W |
| Interface | Integrated 8″ touchscreen display |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PTR-QMS 300 |
| Price | Upon Request |
| Mass Range | 1–300 amu |
| Resolution | <1 amu |
| Response Time | 100 ms |
| Dwell Time per Mass | 2–60 ms |
| Detection Limit | 500 pptv (for selected VOCs) |
| Linear Dynamic Range | 500 pptv – 10 ppmv |
| Inlet Flow Rate | 50–500 sccm |
| Inlet Heating Range | Up to 150 °C |
| Reaction Chamber Heating Range | 40–130 °C |
| Power Supply | 100–230 V AC, max. 650 W |
| Dimensions (W×H×D) | 61 × 47 × 63 cm |
| Weight | 55 kg |
| Data Interface | Ethernet (RJ-45) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 10K |
| Detection Principle | Proton-Transfer-Reaction (PTR) Ionization |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Gas-Stream VOC Analyzer |
| Detection Range | 1 pptv – 100 ppbv |
| Mass Resolution (m/Δm) | ≥10,000–15,000 |
| Accuracy | ±0.001% (relative mass accuracy) |
| Response Time | ≤100 ms |
| Detection Limit | <1 pptv |
| Sensitivity | >1000 cps/ppbv |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 6000X2 |
| Detection Limit | < 1 pptv |
| Sensitivity | > 2000 cps/ppbv |
| Mass Resolution | > 6000 (m/Δm, FWHM) |
| Ionization Modes | H₃O⁺, NO⁺, O₂⁺, NH₄⁺ |
| Response Time | < 100 ms |
| Ion Optics | ION-BOOSTER ion funnel + hexapole ION-GUIDE |
| Mass Analyzer | high-resolution iTOF (ion time-of-flight) |
| Optional Modules | SRI, Fast GC, AutoSampler (270-position), Multiplexing inlet, CHARON, LCU, BET |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR3-TOF 10K |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with High-Resolution Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Stream Ambient Air Monitoring System |
| Detection Range | 0.1 pptv – 100 ppbv |
| Mass Resolution | Up to 15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% mass accuracy (calibrated) |
| Response Time | < 100 ms (10–90% step response) |