JenLab
Filter
Showing all 9 results
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2P Microendoscope |
| Application Domain | In Vivo Intratissue Imaging, Clinical Dermatology, Tissue Engineering, Fluorescent Protein Detection |
| Compatible Platforms | DermaInspect® and MPTflex Multiphoton Workstations |
| Optical Sectioning Capability | Depth-Resolved In Situ Imaging of Human Skin and Small Animal Tissues |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2PM™ |
| Type | Imported Scientific Instrument |
| Distribution Channel | Authorized Distributor |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2PM™-Cryo |
| Laser Source | Ti:Sapphire femtosecond oscillator (710–920 nm, 80 MHz, 100–200 fs, <1.3 W) |
| Temperature Range | 77 K to 873 K (−196 °C to +600 °C) |
| Cooling/Heating Rate | 0.01–150 K/min |
| Spatial Resolution | <0.5 µm (lateral), <2 µm (axial) |
| Temporal Resolution | 200 ps (TCSPC, up to 256 time channels) |
| FOV | 250 µm × 250 µm (lateral), ≤2 mm depth |
| Objective | Standard 40×, NA 1.3 (optional objectives available) |
| Software | JenLab Control & JenLab Image |
| Compliance | CE-marked |
| Power Supply | 115 VAC / 60 Hz or 230 VAC / 50 Hz |
| Dimensions (excl. laser) | 700 × 520 × 800 mm³ |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | femt-O-cut |
| Laser Wavelength | 710–990 nm |
| Pulse Duration | < 100 fs |
| Repetition Rate | 80 MHz |
| Avg. Output Power | 1.5 W |
| Numerical Aperture (NA) | 1.3 |
| Lateral Resolution | < 1 µm |
| Axial Resolution | < 2 µm |
| 3D Processing Depth | Up to 100 µm |
| Minimum Feature Size | < 70 nm (FWHM) |
| Scanning Range | 350 × 350 µm (XY), 200 µm (Z) |
| Piezo Z-Stage Precision | 40 nm |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | femtOgene® |
| Laser Pulse Width | < 20 fs (typ. < 150 fs) |
| Repetition Rate | 85 MHz |
| Average Power | 200–400 mW |
| Wavelength | 800 ± 10 nm |
| Objective | 40×, NA 1.3 |
| Scan Range | 350 × 350 µm (H), 200 µm (V) |
| Stage Travel | 120 × 102 mm |
| Dispersion Compensation | Integrated high-order module |
| Operating Temp. | 15–35 °C |
| RH | 5–80% |
| Power Supply | AC 230 V, 50 Hz |
| System Footprint | Base 490 × 280 × 480 mm³ |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPTcompact |
| Pricing | Upon Request |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | MPTflex CARS |
| Detection Principle | Multiphoton Excitation + Coherent Anti-Stokes Raman Scattering (CARS) |
| Spatial Resolution | Subcellular (~0.5 µm lateral, ~1.5 µm axial) |
| Laser Wavelengths | Tunable near-infrared (700–1100 nm for excitation |
| Imaging Depth | Up to 200 µm in human skin *in vivo* |
| Real-time Chemical Contrast | Label-free molecular vibrational fingerprinting (e.g., lipids, proteins, melanin, water, collagen) |
| Regulatory Compliance | CE-marked for clinical research use |
| compliant with IEC 60825-1 | 2014 (laser safety) |
| Software Platform | MPTconsole v5.x with FDA 21 CFR Part 11–ready audit trail and GLP-compliant data archiving |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | MPTflex |
| Laser Source | Near-infrared femtosecond laser |
| Spatial Resolution | Subcellular (≤0.5 µm lateral, ≤1.5 µm axial) |
| Imaging Depth | Up to 200 µm in human skin *in vivo* |
| Detection Mode | Fluorescence & Second Harmonic Generation (SHG) |
| Clinical Compliance | CE-marked as Class IIa medical device per MDR 2017/745 |
| Software Platform | MPTconnect v5.x with FDA 21 CFR Part 11–ready audit trail and GLP/GMP-compatible data archiving |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | TauMap® |
| Type | FLIM/FCS/FRET Multimodal Microscopy System |
| Application Domain | Biomedical Research, Pharmaceutical Development, Live-Cell Dynamics |