Molecular Devices
Filter
Showing all 10 results
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | CloneSelect Imager FL |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CellXpress.ai |
| Pricing | Upon Request |
| Temperature Control | Yes |
| Humidity Control | Yes |
| Incubation Capacity | Up to 44 microplates (2 stackers) or 154 microplates (7 stackers) |
| Imaging Speed | 3.5 minutes per 96-well plate (single channel, single field of view) |
| Environmental Control | CO₂, temperature, and humidity regulation |
| Excitation Wavelengths | 7 LED sources, 365–730 nm |
| Camera Resolution | 24 MP |
| Objective Lenses | 2×, 4×, 10×, 20×, 40× |
| Imaging Channels | Brightfield + up to 6 fluorescence channels |
| AI Decision Engine | Rule-based machine learning for real-time morphological assessment |
| Air Filtration | HEPA filtration + integrated UV sterilization |
| Predefined & Custom Protocols | Yes |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GenePix 4000B |
| Instrument Type | Microarray Scanning System |
| Laser Configuration | Dual-laser (635 nm & 532 nm), Simultaneous Excitation and Detection |
| Resolution Range | 5–100 µm adjustable |
| Scan Speed | ~6.5 min per slide at 10 µm resolution (dual-channel) |
| Optical Path | Non-confocal epifluorescence |
| PMT Auto-balancing | Yes, real-time channel normalization |
| Focus Adjustment | Motorized Z-axis with manual override |
| Laser Power Control | Digitally tunable per channel |
| Calibration | Built-in NIST-traceable performance verification protocol |
| Software Integration | Native compatibility with GenePix Pro 7.x and Acuity 5.x |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | ImageXpress Confocal HT.ai |
| Environmental Control | 30–40 °C ± 0.5 °C |
| Laser Channels | 7-color solid-state lasers |
| Imaging Channels | 8 (DAPI, CFP, FITC, YFP, TRITC, Texas Red, Cy5, Cy7) |
| Objective Compatibility | Up to 25 objectives including oil (NA 1.4), air (NA 0.05–0.95), and water immersion (NA 1.2) |
| Detection | sCMOS camera |
| Confocal Technology | AgileOptix™ spinning-disk confocal |
| Software Suite | MetaXpress® + IN Carta™ |
| Compliance | Supports GLP/GMP workflows, FDA 21 CFR Part 11 audit trail (via optional configuration), ISO/IEC 17025 traceability-ready |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ImageXpress HCS.ai |
| Pricing | Available upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXM-4 |
| Temperature Control | 30–40 °C ±0.5 °C |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | SpectraMax iD5 |
| Detection Modes | Absorbance, Fluorescence (including TRF, FP), Luminescence (top/bottom), TR-FRET, HTRF, BRET, Dual-Luciferase (with injectors) |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.010 OD or ±1.0% (0–3.0 OD) |
| Detector | –5°C Cooled Photomultiplier Tube (PMT) and UV-Enhanced Silicon Photodiode |
| Wavelength Scanning Speed | 30 sec per scan |
| Temperature Control | Ambient to 66°C |
| Shaking Modes | Linear, Orbital, Double-Orbital |
| Plate Formats | 6–384-well, including Western blot membranes |
| Optical System | Hybrid Quad-Grating + Filter-Based Pathway |
| Scan Density | Up to 20 × 20 points per well |
| Software | SoftMax Pro 7 with GxP Compliance (21 CFR Part 11, GLP/GMP audit trail) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SpectraMax Mini |
| Detection Methods | Fluorescence Intensity, Absorbance, Luminescence |
| Functionality | Multimode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL) |
| Detector | Thermoelectrically Cooled (–5°C) Photomultiplier Tube (PMT) and Photodiode |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±2 nm |
| Wavelength Switching Speed | <1 second per wavelength |
| Absorbance Accuracy | <±0.003 OD ±1.0% (0–3 OD) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | QuickDrop |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Compatibility | Yes |