Oakton
Filter
Showing all 13 results
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | CON 150 |
| Measurement Parameter | Single-parameter (Conductivity/TDS/Temperature) |
| Portability | Portable |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–200 ppt |
| Temperature Range | –10.0 to 110.0 °C |
| Accuracy | ±1% FS |
| Minimum Resolution | 0.01 µS/cm (auto-ranging) |
| IP Rating | IP67 |
| Battery Life | 700 hours (2 × AA batteries) |
| Display | 3-line custom LCD with simultaneous conductivity/TDS/temperature readout |
| Calibration | Auto-ranging, single-point per range |
| Temperature Compensation | Automatic (ATC), adjustable β coefficient 0–10 %/°C |
| TDS Conversion Factor | Adjustable 0.4–1.0 |
| Data Storage | 150 manual data points + last calibration record |
| Included Probe | Conductivity Cell 35608-50 (K = 1.0) |
| Compliance | NIST-traceable calibration certificate available (optional) |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | CTSTestr 50 |
| Portability | Pen-style |
| Conductivity Range | 0.0–200.0 µS/cm, 200–2000 µS/cm, 2.00–20.00 mS/cm |
| TDS Range | 0.0–100.0 ppm, 100–1000 ppm, 0.10–10.00 ppt (TDS factor selectable 0.40–1.00) |
| Salinity Range | 0.00–10.00 ppt |
| Temperature Range | 0–60 °C |
| Accuracy | ±1% of full scale (conductivity, TDS, salinity) |
| Calibration | Up to 3-point for conductivity/TDS |
| Temperature Compensation | Automatic (NTC thermistor) |
| IP Rating | IP67 |
| Power | 4 × AAA 1.5 V batteries (included) |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | DO 6+ |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Range | 0.00–20.00 mg/L |
| Accuracy | ±1.5% of full scale |
| Repeatability | ±0.05% |
| Detection Limit | 0.1 mg/L |
| Display Units | mg/L or ppm (selectable) |
| Temperature Compensation | Automatic (manual input of barometric pressure and salinity supported) |
| Power Source | 4 × AAA batteries |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | EC1 |
| Portability | Pen-style |
| Conductivity Range | 0–20.00 mS/cm |
| Temperature Range | 0–50 °C (32–122 °F) |
| Accuracy | ±1% full scale |
| Conductivity Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.5 °C (±0.9 °F) |
| IP Rating | IP67 |
| Battery Life | 400 hours |
| Power Source | 4 × AAA batteries |
| Auto-off | After 8 minutes idle |
| Dimensions | 17.8 × 4.0 × 3.1 cm (7 × 1.5 × 1.25 in) |
| Floatable Housing | Yes |
| Display | Dual-line LCD with stability, calibration, and battery indicators |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | pH 2+ |
| Instrument Type | Pen-style pH Tester |
| Parameter Type | Single-parameter (pH) |
| pH Range | 0–14 |
| pH Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Buffers | NIST and USA traceable |
| Temperature Compensation | Automatic (0–50 °C / 32–122 °F) |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.5 °C (±0.9 °F) |
| IP Rating | IP67 |
| Power Source | Four A76 1.5 V alkaline batteries (included) |
| Battery Life | Up to 100 hours |
| Display | 4-digit dual-line LCD showing simultaneous pH and temperature |
| Brand | Oakton |
|---|---|
| Model | 08369-70 |
| Origin | USA |
| Instrument Type | Mechanical Thermohygrometer |
| Humidity Range | 5–90% RH |
| Temperature Range | –6 to 40°C (22 to 104°F) |
| Humidity Accuracy | ±5% RH (10–90% RH), ±7% RH (5–10% RH) |
| Temperature Accuracy | ±2°C (±3.6°F) |
| Sensor Type | Human Hair Bundle (Hygrometric), Aged Bimetallic Strip (Thermometric) |
| Chart Speed | Constant 2-hour rotation cycle (7-day chart, 172 hours) |
| Chart Dimensions | 9.2 × 20.8 cm (3⅝" × 8³⁄₁₆") |
| Response Time | ~15 min to 45% step change |
| Power | 1 × AA battery (6 months typical life) |
| Dimensions (W×H×D) | 15.2 × 18.7 × 9.8 cm (6" × 7³⁄₈" × 3⁷⁄₈") |
| Compliance | Designed for GLP-aligned environmental monitoring |
| Brand | Oakton |
|---|---|
| Origin | Singapore |
| Model | PCTSTestr 50 |
| Instrument Type | Portable Handheld Water Quality Analyzer |
| Measured Parameters | pH (–1.00 to 15.00), Conductivity (0 to 20 mS/cm), TDS (0 to 10.0 ppt), Salinity (0.00 to 10.00 ppt), Temperature (0 to 60 °C / 32 to 140 °F) |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Accuracy | ±1% FS |
| TDS & Salinity Accuracy | ±1% FS |
| Temperature Accuracy | ±0.5 °C (0–50 °C), ±1.0 °C (50–60 °C) |
| Auto Temperature Compensation | Yes |
| Calibration | Up to 3-point pH with USA/NIST buffer recognition |
| IP Rating | IP67 |
| Power | 4 × 1.5 V button cells (CR2032), ~150 h battery life |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Oakton pH/ORP |
| Pricing | Available Upon Request |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | PH150 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | pH, Temperature |
| pH Range | –2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Calibration Points | Up to 6 (US, NIST, DIN buffer sets) |
| mV Range | ±2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV or ±0.5% of reading (whichever is greater) |
| Temperature Range | –10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Calibration Offset | Adjustable in 0.1 °C increments |
| ATC | Automatic or Manual |
| IP Rating | IP67 |
| Display | Triple-line LCD (pH/mV, temperature, calibration slope %) |
| Data Storage | 150 manually stored datasets + calibration log |
| Battery Life | Up to 700 hours (2 × AA) |
| Optional AC Adapter | 09376-01 |
| Dimensions | 20 × 8.3 × 5.7 cm |
| Weight | 0.5 kg |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | pHTestr 50 |
| Instrument Type | Pen-style pH Tester |
| Parameter Type | Single-parameter (pH) |
| pH Range | –1.00 to 15.00 pH |
| pH Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Buffers | NIST and USA traceable standards (4.01, 6.86, 9.18 and 4.01, 7.00, 10.01) |
| Temperature Compensation | Automatic (0–60 °C / 32–140 °F) |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.5 °C (±0.9 °F) from 0–50 °C |
| Power | Four AAA 1.5 V batteries (included) |
| Battery Life | Up to 250 hours |
| IP Rating | IP67 (submersible up to 1 m for 30 min) |
| Electrode Type | Replaceable double-junction pH sensor with Kynar® junction and recessed glass bulb |
| Housing Material | Chemically resistant Valox® polymer |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | pHTestr10BNC |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | -1 to 15 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | Up to 3-point |
| Buffer Recognition | Automatic NIST and USA standard buffer identification |
| Temperature Range | -5 to 50 °C (23 to 122 °F) |
| Temperature Compensation | Manual |
| IP Rating | IP67 |
| Display | LCD with backlight |
| Input | BNC pH electrode connector, 8-pin mini-DIN temperature probe port |
| Power | 4 × A76 (LR44) batteries |
| Battery Life | Extended via auto-off and low-battery indicator |
| Enclosure Material | Valox® polymer housing |
| Floatation | Buoyant design for accidental submersion recovery |
| Diagnostic Features | Self-diagnostics with error codes |
| Additional Functions | Hold function, automatic shutdown, battery status indicator |
| Brand | Oakton |
|---|---|
| Origin | USA |
| Model | T-100 |
| Type | Portable |
| Measurement Range | 0–19.99 NTU, 20.0–99.9 NTU, 100–1000 NTU |
| Resolution | 0.01 NTU (0–19.99), 0.1 NTU (20.0–99.9), 1 NTU (100–1000) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±2% of reading (0–500 NTU), ±3% of reading (500–1000 NTU) |
| Light Source | Infrared LED |
| Sample Volume | 10 mL |
| Cuvette Dimensions | 25 mm diameter × 50 mm height |
| Response Time | <6 seconds |
| Power Supply | 4 × AAA batteries (included) |
| IP Rating | IP67 |
| Compliance | ISO 7027 (DIN EN 27027), ASTM D6855-03 (EPA-recognized) |
| Brand | Oakton |
|---|---|
| Origin | Singapore |
| Model | T100 |
| Form Factor | Benchtop/Laboratory |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU (0–19.99 NTU), 0.1 NTU (20–99.9 NTU), 1 NTU (100–1000 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±2% of reading (0–500 NTU), ±3% of reading (501–1000 NTU) |
| Repeatability | ±1% of reading |
| Calibration Points | 4-point (0.02, 20.0, 100, 800 NTU) |
| Light Source | Infrared LED (850 nm) |
| IP Rating | IP67 |
| Power Supply | 4 × 1.5 V AAA alkaline batteries (>1200 measurements per set) |
| Dimensions (Instrument) | 15.5 × 6.8 × 4.6 cm |
| Weight (Instrument) | 200 g |
| Sample Volume | 10 mL |
| Response Time | <6 seconds |
| Compliance | ISO 7027, DIN 27027, US EPA Method 180.1 (non-formazin standard) |