PolyK Technologies
Filter
Showing all 9 results
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CPE1901 |
| Voltage Amplifier Output | >10 kV to 30 kV |
| Charge Range | 1 nC to >1 mC |
| Frequency Range | 0.01 Hz – 1 kHz (standard), up to 300 kHz (with optional HF module) |
| Built-in Amplifier | ±100 V or ±200 V |
| Hysteresis & Breakdown Modes | AC, DC, Field Endurance Life |
| Software Platform | LabVIEW-based with waveform control (sine, triangle, unipolar/bipolar, arbitrary) |
| Optional Modules | Piezoelectric Strain Measurement (10 nm resolution Fotonic Sensor or magnetoelectric sensor), High-Voltage Variable-Temperature Testing (–184 °C to +250 °C) |
| Compliance | Designed for ASTM D149, IEC 60243, IEEE Std 930, and ISO 25777 test protocols |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CPT1705 |
| Max Voltage | ±4000 V |
| Max Current | ±20 mA |
| Frequency Range | 100 Hz – 1 MHz |
| Capacitance Range | 100 pF – 100 nF |
| Temperature Range | −184 °C to 250 °C |
| Optional Cryo/High-Temp Chamber | −75 °C to 200 °C or RT to 1000 °C |
| Optional Frequency Extension | 0.01 Hz – 1 MHz (dependent on integrated impedance analyzer) |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CPT1706 |
| Voltage Range | ±4000 V |
| Current Range | ±20 mA |
| Frequency Range | 100 Hz – 1 MHz |
| Capacitance Range | 100 pF – 100 nF |
| Temperature Range | −184 °C to 250 °C |
| Optional Cryo-Free Chamber | −75 °C to 200 °C |
| Optional High-Temp Chamber | RT to 1000 °C |
| Optional Extended Frequency | 0.01 Hz – 110 MHz (dependent on integrated impedance analyzer) |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PK-CPR1901 |
| Pricing | Available Upon Request |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-HT800 |
| Temperature Range | RT to 800 °C (up to 1000 °C optional) |
| Frequency Range | 20 Hz to 1 MHz (4-terminal shielded) |
| Dielectric Loss Tangent Sensitivity | < 0.1% |
| Sample Capacity | Up to 4 samples per thermal cycle |
| DC Bias Voltage | Up to 4000 V (optional) |
| Includes | High-temperature furnace, ceramic-insulated 4TP test fixture with spring-loaded Pt probes, Agilent/Keysight LCR meter interface (4284A, E4980AL, 4294A compatible), dedicated control software, and thermally rated cabling |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-Pyro |
| Temperature Range | −184 °C to >300 °C (with liquid nitrogen cooling) |
| Current Measurement Sensitivity | down to 1 pA |
| Maximum Electric Field | >100 V/µm (air-gap configuration) |
| Sample Diameter | up to 8 cm |
| Electrode Configuration | spring-loaded spherical electrodes |
| Shielding | fully enclosed, grounded Faraday cage enclosure |
| Compliance | ASTM D257, ASTM D877, IEC 60243-1, ISO 60243-1 |
| Measurement Modes | pyroelectric current, leakage current, thermally stimulated depolarization current (TSDC) |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-Pyro600 |
| Temperature Range | −184 °C to >300 °C (with liquid nitrogen cooling) |
| Current Measurement Resolution | pA-level (10⁻¹² A) |
| Sample Diameter | up to 8 cm |
| Electric Field Capability | >100 V/µm in air |
| High-Voltage Source | ±10 kV (SRS PS350 or Trek 10 kV) |
| Electrometer | Keithley 6517B (or equivalent) with coaxial shielded cabling |
| Shielding | Fully Faraday-shielded test chamber with insulated interior door mount |
| Electrode Configuration | Spring-loaded spherical electrodes for non-damaging contact on soft polymer films (<10 µm thick) |
| Compliance | ASTM D257, ISO 3001-1, IEC 60243-1, GLP/GMP-ready data logging architecture |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CP |
| Voltage Range | Up to 10 kV |
| Electric Field Capability | ≥100 V/µm (up to 200 V/µm demonstrated) |
| Current Resolution | ≤1 pA |
| Temperature Range | –150 °C to >250 °C (with liquid nitrogen cooling) |
| Sample Diameter | up to 8 cm |
| Electrode Configuration | Spring-loaded spherical electrode for soft polymer films (<10 µm thick) |
| Shielding | Fully enclosed, grounded Faraday cage test chamber |
| Compliance | ASTM D257 (extended-field adaptation), ISO 60270 (partial discharge context), GLP-ready architecture |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | ECE-22A |
| Temperature Range | −50 °C to 200 °C |
| Response Time | ≤100 ms |
| Sample Size | up to 20 mm × 20 mm |
| Heat Flux Sensor Sensitivity | >3 µV/(BTU·ft⁻²·hr⁻¹) |
| Thermal Resistance | 0.01 °F·ft²·hr/BTU |
| Thermal Capacitance | 0.02 BTU/(ft²·°F) |
| Data Acquisition | 16-bit ADC |
| Amplifier | Stanford Research Systems SR560 |
| Gain Range | 1–50,000 |
| Bandwidth | DC to 1 MHz |
| Input Noise | 4 nV/√Hz |