| Brand | SCINCO |
|---|---|
| Model | ColorMate |
| Origin | South Korea |
| Instrument Type | Benchtop |
| Optical Geometry | 8°/diffuse (8°/d) |
| Light Source | Pulsed Xenon Lamp (150 W) |
| Spectral Range | 270–1000 nm |
| Measurement Time | ~0.8 s (full spectral scan) |
| Aperture Options | LAV (25.4 mm), MAV (12.7 mm), SAV (6.4 mm or 4.3 mm) |
| Spectral Reflectance Repeatability | <0.1% (STD) |
| Chromaticity Repeatability | ΔE*ab < 0.01 |
| Illuminants | A, C, D50, D55, D65, F1–F12 (17 total) |
| Color Spaces | CIE L*a*b*, L*u*v*, XYZ, Yxy, L*C*h*, Hunter LAB, FMCII, CMC(l:c), BFD(l:c), CIE94 |
| Color Indices | Whiteness, Yellowness, Blueness, Brightness, Opacity, ASTM D1209, Saybolt, APHA, Gardner, ASBC-10, EBC-10 |
| Interface | RS-232 |
| Dimensions (W×D×H) | 500 × 400 × 180 mm |
| Power Supply | AC 100–220 V, 50/60 Hz |
| OS Compatibility | Windows 98/ME/NT/2000/XP |
| Detector | 1024-channel PDA |
| Measurement Modes | Reflectance, Transmittance, Absorbance, Haze |
| Software | ColorMaster Plus (SCI/SCE/UV mode auto-switching, Pass/Fail evaluation, Trend Analysis, Spectral Data Export) |
| Brand | SCINCO |
|---|---|
| Origin | USA |
| Model | DSC N-650 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −150 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Thermocouple Type | Type K |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Baseline Stability | High |
| Heat Flow Sensor Noise Level | Low |
| Cooling Method | Optional Water Cooling |
| Sample Pan Enclosure | Sealed |
| Temperature Control | Dual-PID |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | Lumilux 5100 |
| Excitation/Emission Spectral Bandwidth | ≤ ±0.5 nm |
| Signal-to-Noise Ratio | > 1000:1 |
| Light Source | 150 W Xenon Arc Lamp |
| Detection Range | 190–900 nm |
| Detector Type | Photomultiplier Tube (PMT) |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | NanoVelox |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Sample Volume (Cuvette Mode) | 0.5 µL |
| dsDNA Quantification Range | 2–27,500 ng/µL |
| BSA Quantification Range | 0.06–820 mg/mL |
| Measurement Time | < 8 seconds per sample |
| Operation | Standalone touchscreen interface with internal storage |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SCAB |
| Instrument Type | Aerosol Black Carbon Measurement System |
| Measurement Principle | Real-time Optical Absorption (Filter-Based Transmission Attenuation) |
| Detection Target | Elemental Carbon (EC) / Black Carbon (BC) Mass Concentration in Ambient Air |
| Unit | µg/m³ |
| Portability | Hand-carried, Battery-Operated Field Deployment |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | STA N-650/1000/1200/1500 |
| Temperature Range | –125 to 650 °C, RT to 1000/1200/1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (N-650), 0.1–40 °C/min (N-1000/N-1200/N-1500) |
| Maximum Sample Mass | 400 mg |
| Temperature Accuracy | ±0.1 °C |
| Mass Accuracy | ±0.1 µg |
| Gas Purge | Integrated automatic gas switching (optional) |
| Furnace Design | Vertical micro-balance architecture with water-cooled furnace |
| Compatibility | FT-IR, Q-MS, and other evolved gas analysis (EGA) systems |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | TGA N-1000 / TGA N-1250 / TGA N-1500 |
| Temperature Range | Ambient to 1000°C / 1250°C / 1500°C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 400 mg |
| Heating Rate | 0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500) |
| Cooling Method | Water-cooled furnace housing |
| Gas Control | 4-channel automated gas switching valve |
| Simultaneous Analysis Compatibility | FT-IR and Quadrupole Mass Spectrometry (EGA-ready) |
| Sample Capacity | Single-sample vertical configuration |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Velox 1100 |
| Price Range | USD 21,000–35,000 (FOB) |
| Optical Design | Single-Beam |
| Detector | 512-Element Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | <0.02 nm |
| Photometric Range | –3.0 to +3.0 Absorbance Units (AU) |
| Light Source | Xenon Arc Lamp |
| Spectral Bandwidth | Fixed, Optimized for PDA Architecture |
| Data Acquisition Speed | Full-spectrum acquisition in <100 ms |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | VMS-1S |
| Optical Configuration | Single-beam |
| Detector | 1024-element photodiode array (PDA) |
| Wavelength Range | 400–1000 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Scan Speed | 1 s per spectrum |
| Light Source | Tungsten halogen lamp |
| Sample Stage | Mechanical dual-layer XY stage (210 × 140 mm footprint |
| Eyepiece | Wide-field WF10× (20 mm field diameter) |
| Objective Lens | 5× |
| Measurement Modes | Transmittance and reflectance of small-area optical features (e.g., IR cut filters, camera aperture windows) |