SmartGas
Filter
Showing all 25 results
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Model | Not Specified |
| Price Range | USD 420 – 690 |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YKC Series |
| Pricing | Upon Request |
| Output Options | Analog (4–20 mA / 0–10 V) and Digital (RS485 Modbus RTU, factory-configurable) |
| Maximum Stroke | 2540 mm (100 in) |
| Body Diameter × Length | 89 mm × 89 mm |
| Weight | 907 g |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C2H2 |
| Pricing | Upon Request |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C2H4 |
| Output Signals | 4–20 mA / 0–20 mA analog, 0–1 V / 0–2.5 V analog, RS-485 digital interface |
| Housing | Robust industrial enclosure |
| Connection | Flexible tubing interface |
| Technology | Non-dispersive infrared (NDIR) detection |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CH4 |
| Interface Options | 4–20 mA / 0–20 mA analog output, 0–1 V / 0–2.5 V analog output, RS485 (Modbus RTU), USB |
| Output Signal Types | Current loop, voltage, digital serial, and direct PC interface |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Custom OEM/ODM Available |
| Pricing | Upon Request |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | CO Sensor |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Dual-Beam Compensation |
| Operating Lifetime | ≥10 years |
| Output Interface | RS-485 Modbus RTU |
| Sensitivity | Sub-ppm detection capability |
| Compliance | CE, RoHS, ATEX Category II 2G (optional), IEC 61000-6-2/6-3 EMC |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Technology | NDIR (Non-Dispersive Infrared) |
| Principle | Dual-Wavelength Dual-Beam Spectrophotometry |
| Measurement Range | 0–5000 ppm (standard HVAC configuration) |
| Output | MODBUS RTU (RS-485) and 4–20 mA analog |
| Lifetime | ≥10 years |
| Cross-Sensitivity | Negligible to common interferents (e.g., CO, CH₄, NO₂, H₂O vapor) |
| Operating Temperature | –10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Calibration | Factory-calibrated |
| Brand | SmartGas |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H2 |
| Pricing | Available Upon Request |
| Detection Principle | Electrochemical (H₂-Specific) |
| Operating Temperature | -20°C to +80°C |
| Humidity Range | 5–95% RH (non-condensing) |
| H₂ Measurement Range | 0.2–4.0% vol in air |
| Supply Voltage | 12–24 VDC |
| Output Signal | 1–4.5 VDC (linear, 50 mA max load) |
| Fault Output | 0.0–0.75 VDC (low-fault) / 5.0 VDC (high-fault) |
| Power Consumption | 0.2–0.3 A |
| Response Time (T90) | ≤5 s |
| Recovery Time (T10) | ≤5 s |
| Cross-Sensitivity | Negligible to CO₂, CH₄, CO, and VOCs |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | SM-R134a / SMC-R134a / SMF-R134a / SMP-R134a |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–2000 ppm |
| Lower Detection Limit | 2 ppm |
| Accuracy | ±2% of full scale (±40 ppm) |
| Resolution | 2 ppm |
| Repeatability | ±0.5% of reading |
| Operating Temperature Compensation | Integrated |
| Output Options | 4–20 mA, 0–1 V / 0–2.5 V analog, RS485 (Modbus RTU), USB |
| Enclosure Types | Diffusion (SM/SMC), Flow-through/Pipe-mount (SMF/SMP) |
| Cross-Sensitivity | Negligible to H₂O, CO₂, ethanol |
| Expected Service Life | ≥10 years |
| Compliance | Designed for industrial gas monitoring per IEC 61000-6-2/6-4, EN 61326-1 (EMC), RoHS, CE |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | SM-SF6 / SMC-SF6 / SMF-SF6 / SMP-SF6 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range Options | 0–50 ppm (leak detection), 0–1500 ppm (monitoring), 0–3000 ppm (monitoring), 0–100 % vol. (purity analysis) |
| Resolution | 0.1 ppm (low-range), 1 % (high-range) |
| Accuracy | ±1 ppm (0–50 ppm), ±2 % (0–100 % vol.) |
| Cross-Sensitivity | Immune to H₂O, CO₂, ethanol |
| Output | Digital (I²C, UART) and Analog (4–20 mA, 0–10 V) |
| Lifetime | ≥10 years |
| Power Consumption | Low (typ. <150 mW in standby) |
| Operating Temperature | –20 °C to +50 °C |
| Compliance | Designed for IEC 61000-6-3/-4, RoHS, CE |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | SM-CDT |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–5000 ppm CO₂ |
| Accuracy | ±2% of reading |
| Output Options | Modbus RTU (RS-485), 4–20 mA, 0–1 V / 0–2.5 V |
| Dual-Wavelength Compensation | Yes |
| Temperature Compensation | Integrated |
| Expected Service Life | ≥10 years |
| Power Supply | 12–24 VDC |
| Enclosure Rating | IP65 (for SMF/SMP variants) |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Operating Temperature | –10 to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | SM-R134A |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–2000 ppm |
| LOD | 2 ppm |
| Accuracy | ±2% of full scale (±40 ppm) |
| Resolution | 2 ppm |
| Repeatability | ±0.5% of reading |
| Output Options | 4–20 mA / 0–20 mA / 0–1 V / 0–2.5 V / RS485 (Modbus RTU) |
| Operating Temperature | -20 °C to +50 °C |
| Enclosure Rating | IP65 (SM/SMC variants) or IP67 (SMF/SMP variants) |
| Lifetime | ≥10 years |
| Cross-Sensitivity | Negligible to H₂O, CO₂, ethanol, and common background gases |
| Compensation | Dual-wavelength optical referencing with integrated temperature compensation |
| Brand | smartGAS |
|---|---|
| Origin | Germany |
| Model | SM-SF6 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range Options | 0–50 ppm, 0–100 ppm, 0–100% vol |
| Resolution | 0.1 ppm (low-range), 1% (high-range) |
| Accuracy | ±1 ppm (low-range), ±2% of reading (high-range) |
| Output Signals | 4–20 mA, 0–1 V / 0–2.5 V, RS485 (Modbus RTU), USB |
| Operating Temperature | -10 to +50 °C |
| Lifetime | ≥10 years |
| Cross-Sensitivity | Negligible to H₂O, CO₂, ethanol |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Enclosure Rating | IP65 (SM-SF6 base variant) |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SO2F2 |
| Pricing | Available Upon Request |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YK160-162 Series |
| Price | Upon Request |
| Measurement Range | 0–1079.5 mm (across 60 standard variants) |
| Dimensions (YK160) | 46.0 mm × 57.9 mm × 41.2 mm |
| Weight (YK160) | 113 g |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YK161H–YK162H |
| Measurement Range | 0–1079.5 mm (15 standard variants) |
| Dimensions (YK161H) | 46.0 mm × 57.9 mm × 41.2 mm |
| Weight | 198 g |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Product Type | Imported |
| Model | YK170 Series |
| Stroke Range | 0–165.1 mm (5 standard models) |
| Diameter × Length | 24.4 mm × 11.4 mm (YK170 body) |
| Mass | 28 g |
| Electrical Output | Analog voltage divider (0–V<sub>in</sub>) |
| Potentiometer Type | Single-turn conductive plastic |
| Resistance | 5 kΩ ±10% |
| Mechanical/Electrical Travel | 340° min |
| Linearity Error | ≤±0.5% FS |
| Resolution | Theoretical infinite (analog) |
| Operating Temperature | −65 °C to +125 °C |
| IP Rating | IP54 / NEMA 3S |
| Shock & Vibration | 100 g, 6 ms / 15 g, 10–2000 Hz (per MIL-R-39023) |
| Insulation Resistance | ≥1000 MΩ @ 500 VDC |
| Dielectric Withstand | 1000 VDC min |
| Tempco | ≤±400 ppm/°C |
| Max Supply Voltage | 35 VDC |
| Max Current Draw | 12 mA |
| Power Rating | 1.0 W @ 70 °C |
| Cable Pull Force Options | 0.4–3.3 N (two calibrated ranges) |
| Housing Material | Precision-machined anodized 2024 aluminum |
| Stainless Steel Cable | Ø0.46 mm (7×7), tensile strength ≥177 N |
| [Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model Series | YK173–YK176 |
| Stroke Range | 0–165.1 mm (5 standard models) |
| Body Diameter | 24.4 mm × Length: 11.4 mm (YK170 reference) |
| Mass | 28 g (YK173), up to 113 g (YK176) |
| Electrical Output | Analog voltage divider (0–V<sub>IN</sub>) |
| Potentiometer Type | Single-turn, precision conductive plastic |
| Resistance | 5 kΩ ±10% |
| Mechanical/Electrical Travel | 340° min |
| Linearity Error | ≤±0.5% FS |
| Resolution | Theoretical infinite (analog) |
| Operating Temperature | −65°C to +125°C |
| IP Rating | IP54 |
| Environmental Compliance | DO-160D Category E1E1ABXHXFDXSAXXXXXXXXXX |
| Mechanical Life | 1 × 10⁸ cycles |
| Max Supply Voltage | 35 VDC |
| Max Current Draw | 12 mA |
| Power Rating | 1.0 W @ 70°C |
| Insulation Resistance | ≥1000 MΩ @ 500 VDC |
| Dielectric Withstand | 1000 VDC min |
| Tempco | ≤±400 ppm/°C |
| Cable Pull Force Range | 0.1 N to 3.3 N (model-dependent) |
| Shock & Vibration | 100 g / 6 ms |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YK174-0321T |
| Price | Upon Request |
| Stroke Range | 102 mm (4 in) |
| Cable Tension Capacity | High-Tensile Steel Cable |
| Frequency Response | Up to 5 kHz (typ.) |
| Weight | 85 g |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YK180-0803 Series |
| Price | Upon Request |
| Measurement Range | 0–254.0 mm |
| Dimensions | 37.8 mm × 43.1 mm |
| Weight | 57 g |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | YKD60-D62 Series |
| Resolution | 142 pulses/mm |
| Measuring Range | 0–1092 mm |
| Dimensions | 56 × 64 × 81 mm |
| Weight | 170 g |
| Operating Temperature | −40 °C to +85 °C (−40 °F to +185 °F) |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | SO2 |
| Type | NDIR Infrared Gas Sensor |
| Compliance | CE, RoHS, ATEX optional |
| Output Signal | 4–20 mA / 0–10 V / Modbus RTU (RS-485) |
| Operating Temperature | −20 °C to +50 °C |
| Enclosure Rating | IP65 |
| Response Time (T90) | < 30 s |
| Zero Drift | < 2 % FS/year |
| Span Drift | < 2 % FS/year |
| Cross-Sensitivity | < 1 % to CO₂, NO₂, H₂S, CH₄ |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Model | YK6 Series |
| Maximum Stroke | 2159 mm (YK62 Series) |
| Dimensions | 56 mm × 64 mm × 107 mm |
| Weight | 170 g |
| Operating Temperature | Industrial Range |
| Ingress Protection | NEMA 4 / IP66 |
| Output Options | Factory-Configurable FlexSignal™ Analog and Digital Outputs |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | YKL Series |
| Output Options | Analog (0–10 V / 4–20 mA) and Digital (RS485 Modbus RTU, factory-configured) |
| Stroke Range | 540 mm (21.25 in) |
| Body Diameter | 43 mm |
| Length | 39 mm |
| Weight | 85 g |
| Mounting | Threaded M30×1.5 body with integrated mounting flange |
| Operating Temperature | –20 °C to +70 °C |
| IP Rating | IP67 |
| Repeatability | ±0.02 % FS |
| Linearity | ±0.1 % FS |
| Response Time | <1 ms |