| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite F50 |
| Detection Method | Absorbance |
| Detection Technology | Photometric (LED-based) |
| Measurement Modes | Endpoint, Kinetic, Multi-Label (sequential absorbance reads) |
| Read Channels | 8-channel simultaneous detection |
| Automation Level | Semi-Automatic |
| Light Source | Long-life LED (no warm-up, no alignment required) |
| Software | Magellan v7.x with FDA 21 CFR Part 11 compliance modules |
| Regulatory Compliance | EU IVDR 2017/746 (formerly 98/79/EC IVD Directive), FDA 21 CFR Part 11 audit trail & electronic signature support |
| Vibration Control | Adjustable speed and duration |
| Optical Path Correction | Reference well normalization supported |
| Data Export | CSV, Excel, PDF, XML |
| Interface | USB 2.0, Ethernet |
| Plate Formats | 6–384-well microplates (standard footprint) |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | F50 |
| Function Type | Multimode |
| Automation Level | Semi-Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0–4.00 OD |
| Linearity Range | 0.000–2.000 Abs |
| Optical Channels | 8-Channel Simultaneous Detection |
| Wavelength Accuracy | ±2 nm |
| Absorbance Resolution | 0.0001 OD |
| Read Speed | <10 sec per 96-well plate (single wavelength) |
| Light Source | High-Stability LED Array |
| Plate Formats | 6–384-well microplates, cuvettes (optional) |
| Compliance | ISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite® 200 PRO |
| Detection Modes | Up to 8 (Absorbance, Fluorescence Intensity, Time-Resolved Fluorescence, Fluorescence Polarization, Luminescence, AlphaScreen/AlphaLISA®, BRET, TR-FRET/HTRF) |
| Plate Formats | 6–384-well microplates, PCR plates, cuvettes |
| Wavelength Range | 230–1000 nm (monochromator-based) |
| Absorbance Linearity | < ±0.2% deviation |
| Z-axis Auto-Focusing | Yes |
| Gas Control Module (GCM) | Optional O₂/CO₂ regulation for live-cell assays |
| Detector Types | Photomultiplier tube (PMT) for fluorescence/luminescence |
| Software Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP data integrity features |
| Regulatory Alignment | Designed to support ISO/IEC 17025, CLSI EP12-A2, and USP <1033> validation protocols |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | MagicPrep NGS |
| Intended Use | Research Use Only (RUO) |
| Automation Level | Fully Integrated, Walk-Away Operation |
| Platform Compatibility | Illumina Sequencing Platforms |
| Throughput | Up to 96 samples per run |
| Setup Time | <10 minutes |
| Library Prep Workflow | Fragmentation, End Repair, A-Tailing, Adapter Ligation, PCR Amplification, Cleanup |
| Success Rate | >99% (based on internal validation studies under controlled lab conditions) |
| Regulatory Status | Not for clinical diagnostic use |
| Compliance | Designed in accordance with ISO 13485-aligned quality system principles for RUO instrumentation |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | T48 |
| Instrument Type | Fully Automated Western Blotting System |
| Automation Level | Fully Automated |
| Sample Capacity | Up to 48 samples per run |
| Incubation Temperature Control | Peltier-based active heating and cooling (range: 4–65 °C) |
| Wash Throughput | Simultaneous processing of up to 3 membrane strips |
| Reagent Delivery | Precision peristaltic pumps with auto-calibration |
| Waste Management | Dual-channel segregated waste collection (hazardous & biohazard) |
| Software | Blotware™ v5.x with audit trail, user access levels, and protocol scheduling |
| Compliance | Designed for GLP/GMP environments |
| Brand | Tecan |
|---|---|
| Origin | USA |
| Model | M10-96 |
| Channel Configuration | 96-channel parallel processing |
| SPE Format | Column-based (1 mL, 3 mL, 6 mL cartridges) and 96-well plate-compatible |
| Flow Rate Control | 0.1–30 mL/min (adjustable via dual-range pressure regulation) |
| Sample Capacity | Up to 96 samples per run |
| Sample Load Volume | 0.05–2 mL per channel |
| Solvent Compatibility | Unlimited solvent types (including acetonitrile, methanol, ethyl acetate, dichloromethane, hexane, and aqueous buffers) |
| Wetted Materials | PTFE, polypropylene (PP) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model No. | 253-0014 |
| Channel Count | Multi-channel |
| Extraction Format | Cartridge-based SPE |
| Flow Rate Control | 0.1–100 mL/min |
| Solvent Selection | Up to 11 independent solvent lines |
| Sample Capacity | 48 samples per run |
| Sample Loading Volume | ≤80 mL per sample |
| Wetted Materials | PTFE, Polypropylene (PP), Stainless Steel (316) |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Model | 253-1160 |
| Channel Configuration | 96-channel parallel processing |
| SPE Format | Cartridge-based (1 mL columns) and 96-well plate compatible |
| Flow Rate Control | 0.1–60 mL/min (positive-pressure driven) |
| Solvent Selection | Up to 11 independent solvent channels |
| Sample Capacity | 1–96 samples per run |
| Sample Load Volume | 0.5–100 mL per sample |
| Wetted Materials | PTFE, polypropylene (PP), stainless steel (316 SS) |
| System Footprint | Compact benchtop design |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Spark Cyto |
| Automation Level | Fully Automated |
| Detection Modes | Fluorescence Imaging, Brightfield, Multimode Plate Reading (Absorbance, Fluorescence Intensity, Luminescence, Time-Resolved Fluorescence, FRET) |
| Imaging Capabilities | Widefield Epifluorescence, Full-Well Capture per Field, Z-Stacking, Kinetic Time-Lapse, 2D & 3D Cell Culture Compatibility |
| Objectives | 2×, 4×, 10× (Motorized, Auto-Focus Enabled) |
| Fluorescence Channels | 4 Independent Filter Sets (Configurable) |
| Software Platform | SparkControl™ MAGNA with Real-Time Experiment Control (REC), GLP-Compliant Audit Trail, FDA 21 CFR Part 11 Ready |
| Throughput Options | Standalone or Integrated with Tecan Fluent/Genesis Liquid Handling Platforms and Incubation Modules (e.g., Gas-Controlled Multi-Plate Incubator) |
| Brand | Tecan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Spark |
| Pricing | Available Upon Request |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | Spark |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (UV-Vis spectral scanning), Fluorescence Top/Bottom Read (including 3D fluorescence spectral scanning), Time-Resolved Fluorescence (TRF), TRF Spectral Scanning, Fluorescence Resonance Energy Transfer (FRET), Time-Resolved FRET (TR-FRET), Fluorescence Polarization (FP), Luminescence (Glow, Flash, Multicolor, High-Sensitivity Luminescence Spectral Scanning), AlphaScreen®/AlphaLISA®/AlphaPlex®, Real-Time Brightfield Cell Imaging (Cell Counting & Confluence Analysis) |
| Wavelength Range | 200–1000 nm |
| Additional Modules | Cuvette Port (Absorbance), NanoQuant Plate, Temperature Control (RT +3 °C to 42 °C), Integrated Liquid Handling with Heating & Stirring, CO₂ & O₂ Gas Control Module, Humidity Chamber (Volatile Compound Protection), Te-Cool™ Active Cooling (18–42 °C), Automatic Lid Lifting, Built-in QC Tools (IQ/OQ Support), Integrated Spark-Stack™ Microplate Stacker |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Sunrise |
| Type | Absorbance Microplate Reader |
| Automation Level | Fully Automated |
| Measurement Methods | Single-/Multi-wavelength, Kinetic Assays |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0–3.0 OD (340–399 nm), 0–4.0 OD (400–750 nm) |
| Linearity | 0.000–2.0 OD |
| Detection Speed | Full-plate scan in 5 seconds (12-channel parallel detection) |
| Optical Resolution | 0.001 OD |
| Filter Options | 4-position, 6-position, or continuous monochromator (400–700 nm) |
| Compliance | FDA 21 CFR Part 11 (Magellan Tracker), EU IVD Directive 98/79/EC (Magellan Clinical) |
| Software Platform | Magellan™ (PC & embedded Windows CE versions) |
| Integration Capability | Compatible with Freedom EVO® and Freedom EVOlyzer® automated platforms |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Sunrise |
| Detection Method | Absorbance |
| Function Type | Multifunctional |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Detector Type | Photodiode Array-Based Absorbance Detector |
| Regulatory Compliance | EU In Vitro Diagnostic Directive 98/79/EC |
| Software | Magellan™ v7.x (Multilingual: English, German, French, Italian, Spanish, Russian, Chinese) |
| Design | Modular Base System with Optional Upgrades (Variable Wavelength Selection, Precise Temperature Control, Barcode Reader, Plate Shaking) |
| Intended Use | Clinical Diagnostics, ELISA, Cytotoxicity Assays, Enzyme Kinetics, Quality Control in IVD Laboratories |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Platform | Freedom EVO-based modular system |
| Column Capacity | 96 RoboColumn® positions |
| Parallel Sample Processing | Up to 8 samples simultaneously |
| Compatible Columns | Atoll MediaScout® RoboColumns, GE Healthcare PreDictor™ RoboColumns |
| Application Scope | Expression screening, clone selection, media optimization, mAb purification condition scouting, resin evaluation, gradient method development, buffer exchange, desalting, concentration, and sample prep for crystallization or mass spectrometry |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Model | Uno |
| Type | Fully Automated Benchtop System |
| Sample Volume | 20 µL |
| Throughput | 400 cells per run |
| Temperature Control | Ambient |