Thermo Fisher
Filter
Showing 91–120 of 376 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD 4500 |
| Instrument Category | Radiation Dosimetry System |
| Instrument Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Measured Radiation Types | Photons (>1 keV), Neutrons (thermal to 100 MeV), Electrons (>70 keV) |
| Dynamic Range | 7 decades |
| Readout Time | <35 s (2-element card), <60 s (4-element card) |
| Linearity | ±1% deviation |
| Reference Light Stability | <1% variation over 10 consecutive reads |
| Glow Curve Heating Profile | Preheat 0–100 s, Ramp Rate 1–30 °C/s, Max Temp 300 °C (Teflon), 400 °C (Kapton), 600 °C (metal disk) |
| Dose Range (metal-disk heating) | 10 µGy–1 Gy (linear), 1–20 Gy (supralinear) |
| Reusability | 500 cycles (TLD-100 chips), 50 cycles (extremity rings) |
| Operating Temperature | 0–40 °C |
| Dimensions | 370 H × 460 W × 500 D mm |
| Weight | 35 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory-Based TLD Reader |
| Model | Harshaw TLD 5500 |
| Detector Type | Cooled Photomultiplier Tube (PMT) |
| Sample Capacity | Up to 50 TLD chips per cycle |
| Heating Method | Gas-Heated Linear Ramp (TTP) |
| Max Temperature | 600 °C |
| Linearity | ±1% deviation |
| Dynamic Range | 7 decades |
| Preheat Time | 30 min |
| High Voltage Range | 500–1200 V |
| HV Stability | ±0.005% |
| Dose Units | nC, µGy, mGy, Gy, mrad, mrem, µSv, mSv, Sv |
| Dark Current Equivalent | <50 mGy (Cs-137) |
| MTBF | >10,000 hours |
| Operating Temp | 0–40 °C |
| Storage Temp | −10–60 °C |
| Compliance | Designed for ISO/IEC 17025-accredited dosimetry laboratories |
| Software | Harshaw TLD Analysis Suite with audit trail and 21 CFR Part 11 readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Thermoluminescent Dosimeter (TLD) Reader |
| Model | Harshaw TLD 6600 |
| Detector Type | TLD Reader |
| Radiation Types Measured | Photons (X-rays, γ-rays), Neutrons |
| Measurement Scope | Personal Dose, Environmental Dose |
| Linear Dose Range | Up to 20 Sv |
| Compliance | IEC 61066, ISO 14146, ANSI N13.32 |
| Operating Mode | Benchtop (not portable — corrected per technical specification) |
| Calibration | Automated, Traceable to NIST Standards |
| Quality Control | Built-in QC routines with pass/fail reporting |
| Light Sensitivity | Immune to ambient light interference (non-OSL design) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM11 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Type | Portable |
| Measurement Target | Human Hands and Feet |
| Detector Type | High-Performance Scintillation-Based Hand/Foot Probe Array |
| Measurement Mode | Surface Radioactive Contamination Screening |
| Sensitivity | High (optimized for low-level β/γ emitters, e.g., ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs, ⁶⁰Co) |
| Compliance | IEC 61098:2017 (Radiation Protection Instrumentation — Hand and Foot Contamination Monitors) |
| Display | Large-area capacitive touchscreen LCD |
| Power Consumption | Low (<5 W standby, <12 W operational) |
| Data Storage | Internal non-volatile memory (≥10,000 measurement records with timestamp, operator ID, and location tag) |
| Calibration | Automated self-calibration routine with reference source verification |
| Optional Configuration | Integrated whole-body contamination probe module (for supplementary torso/leg screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Optical System | Echelle grating with cross-disperser |
| Spectral Range | 166–847 nm |
| Resolution | High spectral resolution for trace analysis in complex matrices |
| Detector | High-sensitivity CCD |
| RF Generator | 27.12 MHz solid-state |
| Power Range | 750–1500 W (adjustable) |
| Cooling | Air or water cooling |
| Nebulizer | Concentric or optional ultrasonic |
| Spray Chamber | Chemically resistant (e.g., PTFE) |
| Peristaltic Pump | 4-channel, flow-rate adjustable |
| Sample Throughput | As low as 30 s per sample |
| Detection Limits | Sub-ppb (element-dependent) |
| Linear Dynamic Range | 6–7 orders of magnitude |
| Precision | RSD < 2% |
| Software | Thermo Scientific iTEVA |
| Compliance | 21 CFR Part 11 ready |
| Dimensions | ~700 × 650 × 600 mm |
| Weight | ~80 kg |
| Power Supply | 200–240 V, 50/60 Hz |
| Operating Environment | 15–30 °C, <80% RH (non-condensing) |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCAP 7000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Price Range | USD 135,000 – 162,000 (estimated FOB UK) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | iCAP PRO |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Produced |
| Model | iCAP PRO Series ICP-OES |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | iCAP Pro X Duo |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCAP TQ |
| Instrument Type | Triple Quadrupole ICP-MS |
| Quadrupole Configuration | Three Sequential Quadrupole Mass Filters |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ICS-2100 |
| Rental Rate | USD 1,200–1,350/month (FOB China) |
| Instrument Type | Analytical Instrument |
| Rental Term | Monthly |
| Availability | In Stock |
| Payment Terms | 100% Advance Payment via Wire Transfer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | ICS-5000+ |
| Instrument Type | Laboratory Benchtop System |
| Compliance | ASTM D4327, ISO 14911, USP <645>, EPA Methods 300.0/300.1/310.0/321.8 |
| Software | Chromeleon 7.3 CDS (21 CFR Part 11 compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICS-900 |
| Instrument Type | Analytical Instrument |
| Rental Term | Minimum 3 months |
| Rental Basis | Monthly |
| Lead Time | In Stock |
| Payment Terms | 100% Prepayment |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FPD Detector |
| Instrument Type | Flame Photometric Detector |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ISQ EC |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Analyzer | Quadrupole |
| Scan Rate | Up to 20,000 Da/s |
| Ionization Modes | Electrospray Ionization (ESI), Heated Electrospray Ionization II (HESI-II), and optional Atmospheric Pressure Chemical Ionization (APCI) |
| Software Platform | Thermo Scientific Chromeleon CDS v7.3 or later |
| Regulatory Compliance Support | 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signatures, and GxP-ready workflows |
| Detection Mode | Full Scan, Selected Ion Monitoring (SIM), and Auto-SIM |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC IsoLink |
| Instrument Category | Dedicated HPLC–IRMS Interface System |
| Measurement Precision | High-precision isotopic ratio detection (δ¹³C, δ²H, δ¹⁵N, δ¹⁸O achievable with <0.2‰ 1σ reproducibility under optimized conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | LFM-3 |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Form Factor | Portable |
| Measurement Target | Radioactive Sources and Nuclear Materials |
| Detector Type | Dual NaI(Tl) Scintillation Detectors |
| Energy Channels | Low-, Medium-, and High-Energy Discrimination Channels |
| Detector Housing | Lead-Shielded Enclosure |
| Dimensions | 144 × 455 × 178 mm |
| Weight | 6.7 kg |
| Compliance | Designed for compliance with ANSI N42.33, IEC 60846-1, and applicable ISO 2889 radiation monitoring requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Type | Tube Furnace |
| Temperature Range | 1100°C to 1700°C |
| Heating Zone Lengths | 304.8 mm, 609.6 mm, or 914.4 mm |
| Configuration | Single-Zone or Triple-Zone |
| Controller | Integrated or External Microprocessor-Based Programmable Controller |
| Orientation | Horizontal or Vertical |
| Compliance | Designed for ASTM E1142, ISO/IEC 17025-compliant laboratory environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Lindberg/Blue M |
| Model | BF517xxC / BF518xxC Series |
| Chamber Volume | 1.99 L, 5.3 L, 18.4 L, or 42.5 L |
| Max Operating Temperature | 1100°C |
| Control Options | Digital Single-Setpoint or Multi-Step Programmable Controller |
| Power Supply | 208–240 V, 50/60 Hz |
| Heating Power | 1.8 kW (1.99–5.3 L), 3.5 kW (18.4 L), or 5.6 kW (42.5 L) |
| External Cooling Surface Temp | <60°C at 1100°C operation |
| Safety Features | Door-Interlocked Power Cut-off, Adjustable Over-Temperature Protection, K-Type Thermocouple |
| Gas Ports | 1" Top Exhaust + 3/8" Rear Inlet |
| Construction | Dual-Wall Insulated Steel Housing with Embedded Heating Elements |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Model | Linistat |
| Automation Level | Semi-Automatic |
| Instrument Type | Non-Rotary Linear Stainer |
| Staining Stations | 14 (20 sec/station) |
| Throughput | ≤5 min per batch (13 slides) |
| Slide Capacity | 13-slide collection tank |
| Water Rinse Tank | Position-adjustable |
| Footprint | Compact, designed for placement atop cryostats |
| Compatible Stain | Optimized for Hematoxylin-Eosin (H&E) staining of frozen sections |
| Compatible Reagents | Thermo Scientific Cryochrome™ embedding media and color-coded slide holders |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LUXET Thermo100 Lock-in Infrared Microscope |
| Price | USD 13,500 (FOB USA) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LXQ Linear Ion Trap Mass Spectrometer |
| Price Range | USD 140,000 – 280,000 (estimated FOB US) |
| Instrument Type | Ion Trap |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | MDS |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Principle | Scintillation Detection & Neutron Proportional Counting |
| Detector Types | 5-L Plastic Scintillator (Primary), Optional He-3 Neutron Detector |
| Measurement Range | 1 nSv/h – 20 µSv/h |
| Sensitivity | 20,000 cps/µSv/h (for Cs-137) |
| Energy Response | 50 keV – 3 MeV |
| Background Count Rate | ~500 cps |
| Minimum Detectable Increase | ≥2 nSv/h above background |
| GPS | 6-Channel Satellite Receiver with Real-Time Georeferencing |
| Operating Temperature | −20 °C to +55 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 V DC |
| Internal Battery | 8 h continuous operation |
| Enclosure | Zargus MIL-STD-810G Certified Transport Case |
| Weight | 15 kg |
| Dimensions (Detector Unit) | 40 × 60 × 35 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | microPHAZIR GP |
| Principle | Portable, Non-Destructive NIR Spectroscopy |
| Weight | 1.3 kg |
| Spectral Range | 1600–2400 nm |
| Measurement Time | ≤3 s (configurable) |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory |
| Data Transfer | USB (text-based .csv/.txt) |
| Operating Temperature | 5–40 °C |
| Battery | Rechargeable Li-ion with Hot-Swap Capability |
| Enclosure | Dust- and Splash-Resistant High-Impact Polymer Housing |
| Security | Multi-Level Password Protection |
| Standard Accessories | Rugged Waterproof Carry Case, Li-ion Battery Pack, 110/220 VAC Charger, Lanyard |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | microPHAZIR PC Carpet |
| Principle | Portable, On-Site NIR Spectroscopy |
| Weight | 1.25 kg |
| Measurement Time | 1.5 s |
| Light Source | Tungsten-Halogen Lamp |
| Display | Color LCD |
| Data Interface | USB to PC |
| Battery | Rechargeable Li-ion (≥5 h runtime, <2 h recharge time, dual-battery configuration) |
| Enclosure | Dust- and Splash-Resistant Engineering Plastic |
| Preloaded Library | Carpet Fiber Identification Database |
| Security | Multi-Level Password Protection |
| Calibration | Factory-Calibrated, Ready-to-Use Out-of-Box |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR™ Rx |
| Instrument Category | Portable NIR Spectrometer |
| Principle | Portable, non-destructive near-infrared reflectance spectroscopy |
| Wavelength Range | 1600–2400 nm |
| Scan Rate | 2 spectra per second |
| Data Acquisition Interval | 0.5 s (2 Hz) |
| Measurement Mode | Contact-based diffuse reflectance NIR analysis |
| Chemometrics Software | Method Generator™ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mini 900 Series |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Form Factor | Portable / Benchtop Configurable |
| Radiation Types Detected | X-ray and Gamma (γ) Radiation |
| Detector Options | Geiger-Müller (GM) Tube or Scintillation Detector |
| Measurement Principle | Pulse Counting / Analog Voltage Output Integration |
| Display Format | Logarithmic Scale with Simultaneous Background and Net Count Rate Readout |
| Alarm Function | User-Adjustable Threshold with Proportional Audio Feedback |
| Variants | R-Type (General Purpose), G-Type (Gamma-Optimized), D-Type (Dose Rate Calibrated), X-Type (X-Ray Enhanced) |
| Dimensions | 180 mm (W) × 110 mm (D) × 165 mm (H) |
| Weight | 1.0 kg |
| Power Supply | 6 × AA Alkaline or Rechargeable Batteries (Typical Runtime: ~300 hours at 4 hrs/day usage) |
| GM Tube Bias Voltage Range | 300–700 V DC |
| External Power Input | 12–18 V DC |
| High-Voltage Generator Output | 600–1500 V DC |
| Sensitivity | –100 mV negative polarity analog voltage input (for external detector interfacing) |
| Energy Response | Detector-dependent |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MSQ Plus |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Range | m/z 17–2000 |
| Ionization Sources | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| ESI Flow Rate Range | 10 µL/min – 2 mL/min |
| APCI Flow Rate Range | 200 µL/min – 2 mL/min |
| Desolvation Gas Temperature | Ambient to 650 °C |
| Nebulizing Gas | Nitrogen, 12 L/min |
| Ion Source Geometry | M-Path™ Triple-Angle Ion Optics |
| Detector | Ion Bright™ Dual-Polarity Detector |
| Quadrupole Architecture | RF-Stabilized Mass Filter with Pre-Filter |
| Cone Material | Titanium Alloy |
| Cone Cleaning System | Patented Auto-Cleaning Mechanism |
| Compatibility | Salt-Containing Mobile Phases, Phosphate Buffers, Ion-Pair Reagents |