Thermo Fisher
Filter
Showing 151–180 of 995 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Elemental Analyzer |
| Nitrogen Measurement Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Mass Requirement | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Linear Range | 0.001–500 mg N |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Sample Capacity | Up to 125 positions (with optional 4-position carousel) |
| Compliance | ASTM D5142, AOAC 992.15, ISO 14891, EN ISO 16634-1/-2, USP <28>, FDA 21 CFR Part 11 ready (via EagerSmart software audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus GC |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | Focus GC |
| Instrument Age | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FoodDefender RM |
| Instrument Category | Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spatial Resolution | 7–10.5 cm⁻¹ (Raman), 4 cm⁻¹ (IR-equivalent reference) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Weight | 800 g |
| Dimensions | 19.3 × 10.7 × 4.4 cm |
| Laser Output Power | Adjustable (75 / 125 / 250 mW) |
| Numerical Aperture | NA = 0.23 |
| Working Distance | 17 mm |
| Spot Size | 0.14–1.8 mm |
| Integration Time | Manual or auto mode (minimum 5 ms) |
| Delay Time | Configurable (0–120 s) |
| Power Supply | Rechargeable Li-ion battery or two 123A alkaline cells |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Forma 88000 Series |
| Operating Temperature Range | −50 °C to −86 °C |
| Capacity | 949 L |
| Sample Storage | Up to 700 × 2-inch cryoboxes |
| Compressor | Copeland® industrial-grade scroll compressor |
| Power Input | 208–240 V AC, 50/60 Hz |
| Voltage Compensation | Built-in Boost/Buck regulator |
| Energy Mode Options | Eco Mode (up to 15% energy reduction) and High-Performance Mode |
| Ambient Condition | Maintains <−50 °C for ≥4 hours after power loss (25 °C ambient, empty unit) |
| Insulation | Advanced vacuum insulated panels (VIPs) |
| User Interface | Full-color capacitive touchscreen display with real-time monitoring and alarm logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Forma 89000 Series |
| Operating Temperature Range | –50 °C to –86 °C |
| Capacity | 682 L |
| Storage Capacity | Up to 500 × 2-inch cryoboxes |
| Compressor | Copeland Scroll Industrial-Grade |
| Voltage Input | 208–240 V AC, 50/60 Hz |
| Power Management Modes | Energy-Saving Mode (up to 15% energy reduction) & High-Performance Mode |
| Ambient Condition | Maintains < –50 °C for ≥4 hours after power loss (at 25 °C ambient, empty unit) |
| Insulation | Advanced Vacuum Insulation Panels (VIPs) |
| User Interface | Full-color capacitive touchscreen with real-time monitoring and configurable alarms |
| Voltage Compensation | Integrated Boost/Buck current and voltage regulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Forma 900 Series ULT Freezer |
| Configuration | Upright |
| Temperature Range | –50 °C to –86 °C |
| Controller | Microprocessor-based |
| Insulation | 127 mm in-situ foamed polyurethane |
| Door Seal | Triple-point gasket |
| Interior | Stainless steel walls & adjustable stainless steel shelves |
| External Access Port | 25 mm service port |
| Safety Features | Internal door system (4 panels), CO₂/LN₂ backup option, vacuum pressure equalization vent |
| Certifications | UL Listed, CE Marked |
| Power Management | Surge protection + automatic voltage compensation |
| Mobility | Locking 50.8 mm casters |
| Optional Accessories | Chart temperature recorder, external probe interface |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Instrument Type | Low-Temperature Freezer (≥ −60°C) |
| Effective Storage Volume | 651 L |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | 400 W |
| Compressor Configuration | Dual Industrial-Grade Hermetic Compressors |
| Insulation | 127 mm In-situ Foamed Polyurethane |
| Door Seal | Triple-Gasket System |
| Optional Backup Cooling | LN₂ or CO₂ Cascade System |
| Compliance | CE, UL 61010-1, IEC 61000-6-3, ISO 13485 (for medical device storage applications) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | 907 |
| Net Capacity | 793 L |
| Interior Dimensions (W×D×H) | 27 × 36.6 × 51.5 in. (68.6 × 93 × 130.8 cm) |
| Exterior Dimensions (W×D×H) | 38.9 × 46.8 × 77.9 in. (98.9 × 118.9 × 197.9 cm) |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 994 |
| Effective Storage Capacity | 288 standard cryoboxes |
| Internal Dimensions (W×D×H) | 643 × 584 × 1308 mm |
| External Dimensions (W×D×H) | 989 × 846 × 1979 mm |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 3111 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% RH at 37°C |
| Capacity | 6.5 cu. ft. (184 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Imported |
| Models | 3913, 3920, 3940, 3949 |
| Price | $23,600 USD |
| Temperature Range (with Humidification) | 0–60°C |
| Humidity Range | Up to 95% RH at 37°C (excluding Model 3920) |
| Chamber Capacity | 11 cu. ft. (311 L) / 29 cu. ft. (821 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | 3311 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Range & Control | Ambient to 95% RH, actively controlled |
| Chamber Capacity | 11.4 cu.ft. (322.8 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Forma™ Steri-Cycle™ i160 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.1°C |
| Humidity Control | >93% RH at 37°C |
| Chamber Capacity | 165 L |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | G2397-60720 |
| Type | OEM Replacement Component for Gas Chromatography–Electron Capture Detection Systems |
| Compliance | Designed for use with Thermo Scientific™ TRACE™ and ISQ™ GC-MS platforms |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Gallery Beermaster |
| Instrument Category | Alcoholic Beverage and Beverage Analyzer |
| Detection Principle | Photometric (Colorimetric), Enzymatic, and Iso-Alpha Acid Extraction-Based Bitterness (IBU) Analysis |
| Wavelength Range | 275–775 nm |
| Reaction Volume | Microliter-scale (≤100 µL total per assay) |
| Sample Throughput | Random-access, high-volume batch processing |
| Cell Type | Disposable, multi-cuvette, discrete cuvettes |
| Dilution Capability | Automated primary and secondary dilution |
| Blank Correction | Multiple built-in blank reading modes (reagent blank, sample blank, dual-blank) |
| Software Compliance | Audit trail, user access control, method versioning — supports GLP/GMP documentation requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | GC 5000 VOC |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | GC5000 BTX |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Model | Gemini AS |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary Stainer |
| Heating Stations | 5 independent |
| Reagent Positions | 26 or 31 |
| Water Stations | 4 |
| Slide Capacity per Rack | Standard (compatible with standard histology slide racks) |
| Emergency STAT Processing | Yes, priority queueing for urgent cases (e.g., Mohs surgery) |
| Backup Power | 40-minute battery runtime |
| Compliance Features | Integrated fume management, anti-siphon valves, flow regulators, locked slide baskets, password-protected protocol editing |
| Software | Scheduler™ with editable protocols, preloaded Thermo Scientific Signature™ stain protocols |
| Connectivity | USB for protocol/log export |
| Footprint | Compact dual-level design with integrated touchscreen and power supply |
| Safety | Activated carbon filtration or vent adapter kit optional |
| Door Configuration | 4 configurable access doors |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS 180 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 40 |
| Optical Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 50 |
| Optical Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning & Calibration |
| Sample Compartment | Removable, Washable Interior Liner |
| Display | 7-inch HD Touchscreen Interface |
| Method Management | Pre-programmed Smart Start Methods |
| Compatibility | Cuvettes (10 mm pathlength standard), Test Tubes, Microvolume Adapters (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GENESYS™ 140/150 UV-Visible Spectrophotometer |
| Pricing | Available Upon Request |
| Display | 7-inch high-resolution capacitive touch screen |
| Connectivity | Built-in Ethernet |
| Ambient Light Tolerance | Yes — designed for operation with sample compartment open |
| Sample Compartment | Removable, washable base with magnetic positioning and retention |
| Max Cuvette Pathlength | 100 mm |
| Optional Accessories | 8-cell auto-changer, 4-cell changer (for long-path cuvettes), Peltier-controlled single-cuvette holder (20–60 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GENESYS™ 180 UV-Vis Spectrophotometer (Domestically Manufactured) |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical Design | Double-Beam |
| Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
| Photometric Range | –2 A to +3.5 A |
| Photometric Display Range | –3 A to +5 A |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Wavelength Data Interval | 0.1, 0.2, 0.5, 1, 2, or 5 nm |
| Baseline Flatness | ±0.002 A |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Noise (RMS, 60 readings @ 500 nm) | ≤0.00020 A at 0 A, ≤0.00030 A at 1 A, ≤0.00040 A at 2 A |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7-inch HD color touchscreen (800 × 1280 px), tilt-adjustable |
| Sample Compartment | Standard 8-cell changer with swappable sample tower |
| Optional Accessories | 4-cell long-path changer (up to 100 mm pathlength), Peltier-controlled single-cell holder (20–60 °C), syringe autosampler, fiber optic probe coupler |
| Connectivity | Dual USB-A ports, Ethernet, Wi-Fi adapter support (optional), USB printing support |
| Dimensions (L × W × H) | 35.5 × 38.5 × 19.5 cm |
| Weight | 7.5 kg |
| Lamp Lifetime | >5 years (3-year limited warranty) |
| Power Supply | Auto-ranging AC/DC adapter (100–240 V, 50/60 Hz) |
| Scan Speed | Slow / Medium / Fast — up to 1600 nm/min |
| Compliance | Designed and validated per ISO 9001 manufacturing standards |