Thermo Fisher
Filter
Showing 241–270 of 376 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Neo UHPLC |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose LC-MS Platform |
| Flow Rate Range | 100 nL/min–100 µL/min |
| Maximum Operating Pressure | 150 MPa |
| Flow Precision | ≤0.2% RSD or ≤0.1 µL/min SD (whichever is greater), validated per IQ protocol using Cytochrome C tryptic digest peptides (TGQAPGFSYTDANK) |
| Injection Volume Range | 100 nL–100 µL |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 150 MPa (22,000 psi) |
| Sample Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Raman Spectrometer |
| Model | 1064Defender |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | 8–13 cm⁻¹ |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| IP Rating | IP68 |
| Compliance | MIL-STD-810H |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111EL |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 0.001 ppb – 10 ppm |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 253 Plus |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometer |
| Key Technology | 10 kV IRMS Platform |
| Amplifier Resistance | 10¹³ Ω |
| Detector Configuration | Dual-Path, Semi-Mass Baseline Monitoring |
| Magnet Design | High-Stability Electromagnet with Optimized Pole Geometry |
| Workflow Integration | Built-in LIDI (Long Integration Dual-Inlet) Protocol |
| Sample Utilization Efficiency | Up to 3× Higher vs. MAT 253 |
| Minimum Sample Requirement | Reduced by up to 67% vs. MAT 253 |
| Signal-to-Noise Ratio | Enhanced for Low-Abundance Ions (e.g., m/z 47, 48, 49) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | 46i |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 5030iQ and 5014iQ |
| Measured Parameters | PM₁₀, PM₂.₅, PM₁.₀ |
| Compliance | HJ 653–2021, US EPA EQPM-0807-195, EN 12341:2014, ISO 20581:2022 |
| Detection Principle | Synchronized Hybrid Ambient Real-time Particulate (SHARP) — dual-method integration of beta-ray absorption and nephelometry |
| Calibration | Dynamic digital filter-based continuous mass calibration |
| Display | 7-inch color touchscreen with localized UI |
| Filter Tape Capacity | ≥1500 measurement points (≥12 months at standard sampling intervals) |
| Warm-up Time | <30 minutes |
| Software | ePort Remote Management Suite with audit trail, predictive diagnostics, and GLP-compliant data logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | ARGUS VI |
| Instrument Category | Stable Gas Isotope Ratio Mass Spectrometer |
| Measurement Precision | High Precision |
| Analyte Range | Noble Gases (He, Ne, Ar, Kr, Xe) |
| Mass Range | Full Mass Range for Noble Gases (m/z 2–132) |
| Resolution | High Mass Resolution (M/ΔM > 300 at 10% valley) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ARL 9900 |
| Instrument Type | Floor-standing |
| X-ray Tube Power Options | 1.2 kW, 2.5 kW, 3.6 kW, 4.2 kW |
| Elemental Range | Be to U (with appropriate analyzing crystals) |
| Sample Introduction | 8-position, 12-position or 98-position autosampler |
| Weight | ~750 kg |
| Max. Power Consumption | 4.8 kVA |
| Configuration | Scanning-type WDXRF spectrometer with optional simultaneous XRD channel |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Model | ARL EQUINOX 100 |
| Power Stability | < 0.0001 (unitless relative stability, typical for high-stability X-ray tube power supply) |
| Detector | Integrated EQUINOX curved position-sensitive detector (CPSD) |
| Cooling | Fully integrated internal water-cooling system |
| Sample Handling | Optional 6-position autosampler, transmission powder holders, thin-film accessories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ARL EQUINOX Pro |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 3000 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Floor-standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 1080, 1667, and 2160 lines/mm |
| Wavelength Range | 200–760 nm |
| Number of Analytical Channels | 80 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ARL Optim’X |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W / 200 W (equivalent via UCCO™ technology) |
| Elemental Range | F to U (73 elements) |
| Analysis Mode | Simultaneous (fixed-channel) and Sequential (scanning) |
| Cooling | Air-cooled, no external water circulation required |
| Sample Handling | Standard 1-position manual loader |
| Software | Thermo Scientific OXSAS with OptiQuant™ quantitative package |
| Compliance | Designed to meet ASTM E1361, ISO 2936, ISO 8258, and GLP/GMP data integrity requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL PERFORM'X Sequential |
| Price Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Sequential WDXRF |
| X-ray Tube Power | 1.5 kW (ARL PERFORM'X 1500W), 2.5 kW (ARL PERFORM'X 2500W), 4.2 kW (ARL PERFORM'X 4200W) |
| Elemental Range | F (Z=9) to U (Z=92), plus C (Z=6) |
| Detection Limit | Sub-ppm for most elements in optimized matrices |
| Angular Positioning Accuracy | ≤0.0005° (Moiré fringe encoder-based goniometer) |
| Sample Form | Solids (pressed pellets, fused beads), Liquids (sealed cells), Powders, Coatings |
| Automation | Integrated XYZ sample changer with up to 120-position capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific BioMate 3S |
| Optical Design | Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | <0.08% T |
| Automation | Automatic Wavelength Selection |
| Compliance | Meets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CEMS Hg |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ConFlo IV |
| Instrument Type | Continuous-Flow Interface for Stable Gas Isotope Ratio Mass Spectrometry |
| Measurement Precision | High-Precision Isotopic Ratio Detection |
| Reference Gas Compatibility | CO₂, N₂, CO, H₂, SO₂ (≥5 independent reference gas lines) |
| Automation Features | Auto-switching between external analyzers and working gases, real-time H₃⁺ factor monitoring and correction, fully automated gas dilution (1–100% range, extendable) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| Model | Delta Ray |
| Measurement Targets | δ¹³C and δ¹⁸O in CO₂ |
| Precision | < 0.05‰ (1σ) for both δ¹³C and δ¹⁸O |
| Dynamic Range | 200 ppm to 100% CO₂ |
| Calibration Interface | Universal Reference Inlet (URI) with automated reference gas delivery and real-time calibration |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DELTA V Advantage |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometer |
| Measurement Precision | High Precision |
| Price Range | USD 260,000 – 390,000 (based on configuration and regional duties) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dionex Easion |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-5000+ |
| Pump Pressure Rating | 6000 psi |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Integrion |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–22.4 mL/min |
| Eluent Flow Rate Range | 0.001–22.4 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | Ambient +5°C to 80°C |
| Temperature Stability | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Confocal Micro-Raman Spectrometer |
| Model | DXR2xi |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | 500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DXR3 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 3500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | DXR3 Smart |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–3500 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Thermo Scientific DXRxi |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EASY-Spray |
| Instrument Category | Electrospray Ionization (ESI) Source |
| Price Range | USD 420,000 – 560,000 (based on current exchange rate and typical configuration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Magnetic Sector ICP-MS |
| Model | ELEMENT 2/XR |
| Resolution Modes | Fixed Low/Medium/High Resolution Slits |
| Linear Dynamic Range | 12 orders of magnitude |
| Interface | Jet Sample Introduction System |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ELEMENT GD Plus |
| Price Range | USD 700,000 – 14,000,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ELEMENT™ Series ICP-MS |
| Price Range | USD 200,000–270,000 |
| Instrument Type | Sector Field Magnetic Sector ICP-MS |
| Mass Resolution (at 10% peak height, m/Δm) | >10,000 |
| Detection Limit (in aqueous solution, 3σ) | <0.2 fg L⁻¹ for ²³⁸U |
| Sensitivity (for ²³⁸U at 1 µg L⁻¹) | >1 × 10⁹ cps per µg L⁻¹ |
| Dynamic Range | 0.2 cps (SEM) to >1 × 10¹² cps (Faraday) |