Showing 1–30 of 77 results
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1064Defender™ Handheld Raman Analyzer |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Model | 410i |
| Instrument Type | In-situ Online Gas Analyzer |
| Detection Principle | Nondispersive Infrared (NDIR) Spectroscopy with Fixed Bandpass Interference Filter and Quantum-Well Infrared Photodetector (QWIP) |
| Measurement Range (D-type) | 0–10,000 ppm CO₂ |
| Measurement Range (E-type) | 0–25% CO₂ |
| Zero Noise (D-type) | 0.1 ppm RMS (300 s averaging) |
| Zero Noise (E-type) | 10 ppm RMS (60 s averaging) |
| MDL (D-type) | 0.2 ppm |
| MDL (E-type) | 20 ppm |
| Zero Drift (7 days, D-type) | <0.20 ppm |
| Zero Drift (24 h, E-type) | <40 ppm |
| Span Drift (7 days) | <1% reading (D-type), <2% reading (E-type) |
| Operating Temperature Range | –20 °C to +50 °C |
| Compliance | ASTM D6522, EPA Method 3A, ISO 12039, EN 15267-3 (for certified configurations), Supports 21 CFR Part 11 audit trail (with optional software license) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Fixed Bandpass Interference Filter and Quantum Detector |
| Model | 410i |
| Configuration Options | 410i-D (Standard Range), 410i-E (High Range) |
| Measurement Range (D) | 0–10,000 ppm |
| Measurement Range (E) | 0–25% vol |
| Zero Noise (D) | 0.1 ppm RMS (300 s avg) |
| LOD (D) | 0.2 ppm |
| Zero Drift (7 days, D) | <0.20 ppm |
| Span Drift (7 days, D) | <1% of reading |
| Zero Noise (E) | 10 ppm RMS (60 s avg) |
| LOD (E) | 20 ppm |
| Zero Drift (24 h, E) | <40 ppm |
| Span Drift (7 days, E) | <2% of reading |
| Operating Temperature Range | –20 to +50 °C |
| Data Output Options | Direct Extraction or Dilution Mode Reporting |
| Compliance | Designed for EPA Method 3A, ASTM D6522, ISO 12039, and EN 15267-3 environments |
| Software Interface | i-Series Menu-Driven Firmware with Audit Trail Support (21 CFR Part 11 ready) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Gas Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% Full Scale or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC, T90) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ALLpaQ |
| Price Range | USD $26,000 – $68,000 (based on configuration and volume capacity) |
| Application Domain | Biopharmaceutical Manufacturing |
| Brand | Thermo Scientific |
|---|---|
| Origin | Mexico |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Reagent-Free Eluent Generation | Integrated RFIC-EG Technology |
| Software Control | Chromeleon CDS v7.3 or later |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Scientific |
|---|---|
| Origin | Netherlands |
| Model | Arctis |
| Ion Sources | Xe⁺, O⁺, Ar⁺ |
| Sample Capacity | Up to 12 cryo-grids (TomoGrids/AutoGrids) |
| Integrated iFLM | Yes |
| Vacuum System | Ultra-high vacuum cryo-chamber |
| Cooling Architecture | Dual-stage cryo-shielding with braided cryo-sleeve |
| Compliance | Designed for GLP/GMP-aligned cryo-EM workflows, compatible with FDA 21 CFR Part 11–ready software environments |
| Biocontainment Option | High-temperature decontamination mode for BSL-3 labs |
| Stage Tilt Range | ±90° (180° total) CompuStage™ |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DHX |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Aquion |
| Instrument Type | Benchtop Laboratory IC System |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Operating Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Detection Principle | Suppressed Conductivity Detection |
| Pump Technology | Dual-Piston Isocratic/Gradient Capable Pump |
| Eluent Generation | Electrolytic Eluent Generation (EG) compatible |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-6000 HPIC |
| Instrument Type | Laboratory |
| Application Scope | Universal |
| Configuration Flexibility | Modular |
| RFIC™ Capability | Yes |
| Maximum Operating Pressure | 5000 psi |
| Column Particle Size Support | 4 µm |
| Column Dimensions Supported | 150 mm and 250 mm |
| Column Inner Diameter Compatibility | 1–7 mm (capillary to standard bore) |
| Detector Options | CD, ED, VWD, PDA, ICP-MS interface |
| Software Platform | Thermo Scientific Dionex Chromeleon 7.3 CDS |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | G8300 |
| Pricing | Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | E1-ClipTip |
| Instrument Type | Multi-Channel Electronic Pipette |
| Automation Level | Motorized |
| Channel Options | 1-, 8-, and 12-channel configurations |
| Connectivity | Bluetooth 5.0 & USB-C |
| Compliance | ISO 8655-2:2022, ISO/IEC 17025, GLP/GMP-ready audit trail support |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EXTREVA ASE |
| Instrument Type | Vacuum Parallel Concentrator |
| Automation Level | Fully Integrated ASE + Evaporation Workflow |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FGD-CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Dilution Extraction with UV/IR Absorption and Paramagnetic/O2 Electrochemical Detection |
| Key Parameters | SO₂, NOₓ, CO, O₂, Flow Rate, Temperature, Static Pressure, Particulate Matter (PM), Relative Humidity, Total Reduced Sulfur (TRS), H₂S |
| Compliance Framework | EPA Performance Specifications (PS-2, PS-3, PS-5, PS-15), EN 15267, ISO 14001, US EPA Method 6C, Method 7E, Method 10, Method 3A, ASTM D6522, ASTM D5197 |
| Data Integrity | 21 CFR Part 11–compliant audit trail, GLP/GMP-ready reporting |
| Brand | Thermo Scientific |
|---|---|
| Model | 72-320-200 / 72-320-250 |
| Pump Head Type | Quick-Release |
| Tube Replacement Time | < 30 s |
| Operating Voltage | Universal (100–240 VAC, 50/60 Hz) |
| Input Connector | IEC 320 C14 |
| Max. Discharge Pressure | 60 psi |
| Flow Direction | Reversible |
| Display | Digital RPM Readout |
| Control Modes | Volume Dispense, Time Dispense, Programmable Cycle Dispense with Customizable Inter-Cycle Delay |
| Calibration | Dynamic Tube-Specific Calibration Stored in Non-Volatile Memory |
| Safety | Integrated Power Interlock for Tube Change |
| Footprint | Compact, Stackable Design |
| Compliance | CE, UL Recognized, RoHS Compliant |
| Language Support | English, Spanish, French, German, Italian, Chinese, Japanese |
| Brand | Thermo Scientific |
|---|---|
| Origin | Singapore |
| Model | Fluoroskan / Fluoroskan FL / Luminoskan |
| Detection Mode | Fluorescence & Luminescence (Dual-Mode for Fluoroskan FL) |
| Detector Type | Photomultiplier Tube (PMT) |
| Plate Formats | 6–384-well microplates |
| Reading Speed | 18 s per 96-well plate |
| Measurement Modes | Endpoint, Kinetic, Multi-point per well |
| Excitation/Emission Flexibility | Top-read and bottom-read optical paths |
| Dynamic Range | >6 decades |
| Incubation Range | Up to 45 °C with orbital shaking |
| Liquid Handling | Optional integrated reagent dispensers (0, 1, or 2 dispensers) |
| Software | Thermo Scientific SkanIt PC and Cloud-based assay protocol library |
| Compliance | DLReady certified (Luminoskan & Fluoroskan FL), supports GLP/GMP workflows with audit trail capability |
| Brand | Thermo Scientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model Variants | 371 GPCN / 381 GPCN |
| Quotation | Upon Request |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% |
| Chamber Capacity | 184 L |
| External Dimensions | 66.3 cm × 100.3 cm × 63.5 cm (W × H × D) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Benchtop Bioreactors |
| Price Range | USD 135,000 – 405,000 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HyPerforma DS300 |
| Instrument Type | Top-Driven Single-Use Mixing System |
| Price Range | USD 68,000 – 136,000 (based on configuration and accessories) |
| Volume Range | 50–300 L (top-discharge), 50–200 L (bottom-discharge), 50–200 L (closed-top 3D BPC) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | G3Lab |
| Application Category | Biopharmaceutical Process Control |
| Control Capacity | Up to 250 L single-use and steam-sterilizable bioreactors (stirred-tank and orbital/shaker formats) |
| Software Platform | TruBio™ (built on Emerson DeltaV™ DCS architecture) |
| Regulatory Compliance | cGMP-compliant, FDA 21 CFR Part 11-ready, validated DCS architecture |
| System Architecture | Open, modular, IEC 61511-aligned control platform |
| Redundancy Option | Available for critical process loops |
| Calibration | Built-in traceable calibration routines |
| Feed Strategy Support | Multi-component, time-/state-/feedback-triggered feeding protocols |
| Hardware Integration | Integrated I/O modules, peristaltic pumps, sensor transmitters, power management, and network interface hardware |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | G3Lite |
| Application Domain | Biopharmaceutical Manufacturing |
| Regulatory Suitability | Non-GMP and cGMP Facilities |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HyPerforma Glass |
| Price Range | USD 135,000 – 405,000 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HyPerforma SUB |
| Material | Stainless Steel |
| Available Volumes | 50 L, 100 L, 250 L |
| Volume Ratio | 5:1 |
| Controller Platform | Finesse G3Lite Bioreactor Controller |
| Integrated Components | Finesse TruBio™ Software, Laudа TCU, TruTorr™ Pressure Transmitter, Disposable Electrochemical Sensors, Load Cells (up to 3), Mass Flow Controllers (6 total), Watson-Marlow Pumps (3 × WM114, 1 × WM313) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Rocker Bioreactor |
| Working Volume | Up to 25 L |
| Sensor Integration | Integrated TruFluor pH + dO₂ + Temperature sensor |
| Compliance | USP Class 6, cGMP-compliant |
| Sterilization | Gamma-irradiated (25–40 kGy) |
| Controller | HyPerforma G3Lab |
| Software | TruBio v3.x |
| Optional Accessories | Load cell for gravimetric control, tray adapters for 10 L / 20 L BPCs, perfusion-ready configuration |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HyPerforma Smartainer |
| Application Category | Biopharmaceutical Manufacturing |
| Vessel Configurations | Jacketed and Non-Jacketed Options |
| Standard Volumes (Non-Jacketed) | 200 L, 500 L, 1,000 L, 1,500 L, 2,000 L |
| Standard BPC Volumes | 100 L, 200 L, 500 L, 1,000 L, 1,500 L, 2,000 L |
| Primary Material | ASTM A240 Type 304 Stainless Steel |
| Structural Design | Single-wall (non-jacketed) and double-wall (jacketed) configurations |
| Compatible Disposable Liners | Aegis5-14 and CX5-14 film-based BioProcessing Containers (BPCs) |
| Top/Bottom Port Configuration | Dual-port (top-fill/bottom-discharge) for closed-system fluid transfer |
| Regulatory Alignment | Designed to support cGMP-compliant biomanufacturing workflows per FDA 21 CFR Part 11 and EU Annex 11 data integrity requirements |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HyPerforma SUF |
| Volume Options | 30 L and 300 L |
| Scale-up Ratio | 5:1 |
| Aspect Ratio (H | D): 3:1 |
| Drive Configuration | Top-mounted agitator |
| Mixing System | Patented Rushton turbine–based impeller set with integrated sparger and exhaust management |
| Jacketing | Side and bottom thermal jacket for efficient heat transfer |
| Sensor Integration | Integrated temperature, pH, DO, foam, and pressure sensors (single-use compatible) |
| Sterile Port Count | ≥8 (for aseptic filling, sampling, draining, gas inlets/outlets) |
| Foam Detection | Advanced capacitive foam sensor with real-time feedback loop |
| Cable Management | Modular, service-loop–optimized routing system |
| Tooling Support | Adjustable tool rack with ergonomic access |
| Compliance | Designed to support cGMP, FDA 21 CFR Part 11, and ISO 13485-aligned workflows |
| Software Platform | Compatible with Thermo Scientific™ BioProcess™ Control Software (BPCS) v4.0+ |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HyPerforma SUM |
| Instrument Category | Mixing & Homogenization Equipment |
| Volumes Available | 50 L, 100 L, 200 L, 500 L, 1,000 L, 2,000 L |
| Motor Options | AC or Brushless DC with Encoder Feedback |
| Temperature Control | Non-jacketed or Water-jacketed (side & bottom) |
| Weighing System | Triple-load-cell integrated scale |
| Sensor Integration | Temperature, pH, Conductivity, Pressure |
| Film Options | CX5-14 and Aegis5-14 single-use bioprocess containers (BPCs) |
| Sterile Port Configuration | Fill, drain, sampling, vent, and aseptic connection ports |
| Compliance | Designed for cGMP environments |
| Brand | Thermo Scientific |
|---|---|
| Origin | Switzerland |
| Model | Hypulse |
| Instrument Type | XPS with REELS and ISS capabilities |
| Ion Source | MAGCIS dual-mode (Ar⁺/Ga⁺/Cs⁺/O₂⁺) |
| Depth Profiling | Integrated femtosecond laser ablation (fs-LA) system |
| Acquisition Modes | Snapshot mode (<1 s per spectrum), Scanning mode (energy-resolved) |
| Imaging | Stage-based mapping and SnapMap fast imaging |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCAP PRO ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Spectral Resolution | 7 pm at 200 nm |
| Wavelength Range | 167.021–852.145 nm |
| RF Generator | 27.12 MHz, 750–1600 W adjustable |
| Plasma Gas Flow | 0.0–20.0 L/min (MFC-controlled) |
| Nebulizer Gas Flow | 0.0–1.5 L/min (MFC-controlled) |
| Auxiliary Gas Flow | 0.0–2.0 L/min (MFC-controlled) |
| Radial Viewing Height | 6–18 mm |
| Torch Orientation | Vertical |
| Detector | Charge Injection Device (CID) Array |
| Purge Gas | Optional integrated MFC (0–0.25 L/min) |
| Sample Introduction | 4-channel peristaltic pump (0–125 rpm) |
| Warm-up Time | ≤5 min from standby |
| UV Enhancement Mode | Dual UV exposure for improved sensitivity below 240 nm |