Tlyon
Filter
Showing all 14 results
| Brand | Tlyon |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Aurora Z10 |
| Instrument Type | Seed Surface Activation & Bio-stimulation System |
| Power Consumption | <200 W |
| Chamber Volume | 10 L |
| Batch Capacity | 2 L (≈1 kg dry seeds) |
| Display | 10.4-inch capacitive touchscreen |
| Connectivity | Ethernet/Wi-Fi for cloud-based remote monitoring |
| Weight | 143 kg |
| Compliance | CE-marked, RoHS-compliant, meets IEC 61000-6-3 EMC standards |
| Brand | Tlyon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FloraPulse |
| Instrument Type | Plant Water Status Monitoring System |
| Compliance | ASTM D4292-22 (soil-water potential correlation), ISO 10937:2021 (plant physiological monitoring), GLP-aligned data logging |
| Brand | Tlyon |
|---|---|
| Model | FlyPAD |
| Measurement Principle | Capacitive Sensing |
| Channel Capacity | 64 independent channels per unit |
| Scalable Stack | Up to 40 units (2,560 flies simultaneously) |
| Single-Fly Resolution | Yes |
| Throughput | Real-time, continuous feeding event detection at millisecond temporal resolution |
| Compatibility | Standard Drosophila food media (liquid/sucrose/yeast-based), luciferin-containing diets for concurrent bioluminescence assays |
| Regulatory Context | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | Tlyon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EFM |
| Measurement Range | 12–100 mm (0.47–3.94 in) |
| Power Supply | 9 V alkaline battery |
| Units | mm / in |
| Resolution | 1.00 mm |
| Data Storage Capacity | Up to 12,000 measurements |
| Includes | Calibration disc and PC-compatible data analysis software |
| Brand | Tlyon |
|---|---|
| Origin | South Africa |
| Model | FTA |
| Force Measurement Range | 0–15 kg (GS-15) / 0–25 kg (GS-25) |
| Force Resolution | 0.02 kg / 0.04 lb / 0.2 N |
| Probe Speed | 5–35 mm/s |
| Weight Capacity | 30–14,000 g (GS-15) / 30–20,000 g (GS-25) |
| Diameter Measurement Range | 12–100 mm |
| Max Sample Diameter | 120 mm |
| Repeatability | ±0.5% (GS-15) / ±0.4% (GS-25) |
| Power Supply | 110 V or 220 V AC, 50/60 Hz |
| Power Consumption | 100 W (GS-15) / 120 W (GS-25) |
| Interface Options | RS-232, USB, optional EFM, barcode scanner, LCD/keyboard module |
| Brand | Tlyon |
|---|---|
| Origin | Sichuan, China |
| Model | LAM-C |
| Measurement Range | 1–600 cm² |
| Leaf Length | 0–297 mm |
| Max Leaf Width | 0–210 mm |
| Minimum Detectable Hole Area | ≥0.5 cm² |
| Accuracy | ±2% (for leaves >30 cm²), ±3% (for leaves ≤30 cm²) |
| Storage Capacity | >2,000 image-based measurement records |
| Operating Temperature | −30°C to +80°C |
| Relative Humidity | 0–100% RH |
| Response Time | 50 ms |
| Stability | <±2% drift over 12 months |
| Display | 7-inch IPS capacitive touchscreen (Android 4.2.2+) |
| Internal Storage | 32 GB |
| Connectivity | Wi-Fi (802.11 a/b/g/n), Bluetooth 4.0 |
| Interface | micro-USB |
| Power | DC 5 V / 1 A |
| Battery | 3000 mAh |
| Dimensions | 187 × 111 × 9.3 mm |
| Weight | 266 g |
| Brand | Tlyon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMS |
| Instrument Type | Research-grade Small Animal (Mouse/Rat) Respirometry System |
| Sample Volume Capacity | 1 mL |
| Temperature Operating Range | 5–40 °C |
| Measured Parameters | O₂ concentration, CO₂ concentration, water vapor pressure, barometric pressure, relative humidity |
| Flow Rate Range | 1–1000 mL/min (adjustable) |
| Temperature Accuracy | ±0.1 °C |
| Relative Humidity Accuracy | ±1 %RH |
| Barometric Pressure Accuracy | ±0.075 % of full scale |
| Battery | Rechargeable 24 V / 10 Ah Li-ion, ≥8 h field operation |
| Data Storage | Onboard SD card + USB export |
| Compliance | Designed for GLP-compliant respirometry workflows |
| supports ASTM E2913-22 (Standard Guide for Respirometric Measurements in Small Animal Studies) and ISO 8573-1 (Compressed Air Purity — Part 1 | Contaminants and Classifications) for gas stream integrity |
| Brand | Tlyon |
|---|---|
| Model | TLY-500 |
| Extractor Volume | 500 mL |
| Max Operating Pressure | 345 bar |
| Max Temperature | 80 °C |
| Number of Extraction Channels | 2 |
| CO₂ Flow Control | Digital, Adjustable |
| Co-solvent Delivery | Optional, up to 10 mL/min |
| Sample Form Compatibility | Solid (powdered/dried) and Liquid |
| Extract Collection | Direct into Falcon tubes |
| Separation Stage | Dual-stage Falcon-type separator with liquid trap |
| Temperature Control | PID-regulated |
| Safety Systems | Independent electronic + mechanical pressure relief |
| Wetted Materials | 316L stainless steel, honed internal surfaces |
| CO₂ Phase Monitoring | Real-time flow visualization |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Tlyon |
|---|---|
| Model | Tlyon-1020 |
| Measurement Principle | Non-dispersive infrared (NDIR) CO₂ analysis, thermistor-based leaf/ambient temperature sensing, capacitive humidity sensing, calibrated silicon photodiode PAR sensor |
| CO₂ Range | 0–1500 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Accuracy | ±3 ppm |
| Leaf & Chamber Temperature Range | 0–50 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.2 °C |
| Relative Humidity Range | 0–100 % RH |
| RH Resolution | 0.1 % RH |
| RH Accuracy | ≤±3 % RH |
| PAR Range | 0–2500 µmol·m⁻²·s⁻¹ |
| PAR Accuracy | <±5 µmol·m⁻²·s⁻¹ |
| Flow Control | Glass rotameter |
| Chamber Dimensions (Std) | 55 mm × 20 mm |
| Power Supply | 7.4 V DC Li-ion battery |
| Operating Duration | 7–9 h |
| Data Storage | 2 GB microSD card |
| Display | 320×160 dot-matrix LCD, Chinese UI |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (main unit) |
| Compliance | Designed for field-deployable plant physiology studies per ISO 17025-aligned measurement practices |
| Software | On-device data logging with timestamped CSV export |
| Optional Accessories | Modular leaf chambers (I–III), 2 L canopy chamber, 1.4 L soil respiration chamber, plug-and-play red-blue LED light source (0–3000 µmol·m⁻²·s⁻¹, user-adjustable) |
| Brand | Tlyon |
|---|---|
| Model | Tlyon-1022B |
| Detection Principle | Non-dispersive Infrared (NDIR) CO₂ Analysis + Electrochemical O₂ Sensor |
| CO₂ Range | 0–5000 ppm (selectable spans: 0–1000 / 1500 / 2000 / 3000 / 5000 ppm) |
| CO₂ Accuracy | ±3 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Response Time | <1 s (ΔCO₂ acquisition) |
| O₂ Range | 0–99.999% vol |
| O₂ Linearity | ≤±2% F.S. |
| O₂ Repeatability | ≤±1% |
| O₂ Response Time | 30 s |
| Temperature Range | −20 to +95 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Resolution | 0.1 °C |
| Humidity Range | 0–99.999% RH |
| RH Accuracy | ±0.2% F.S. |
| RH Resolution | 0.1% |
| Flow Control | Adjustable via instrument keypad or PC software |
| Standard Chamber Volumes | 0.1 L (Ø40 mm × 80 mm), 0.25 L (Ø60 mm × 89 mm), 2.0 L (Ø120 mm × 180 mm) |
| Data Storage | 32 GB internal flash memory |
| Display | 3.5″ TFT color LCD, 320 × 480 pixels |
| Power Supply | AC 220 V ±10% |
| Compliance | Designed for GLP-aligned experimental workflows |
| Brand | Tlyon |
|---|---|
| Model | Tlyon-1023 |
| Origin | Sichuan, China |
| Air Temperature Range | –20–80 °C (±0.2 °C accuracy, 0.1 °C resolution) |
| Leaf Temperature Range | –20–60 °C (±0.2 °C accuracy, 0.1 °C resolution) |
| Relative Humidity Range | 0–100% RH (±3% RH accuracy, 0.1% RH resolution) |
| PAR Range | 0–3000 μmol·m⁻²·s⁻¹ (<5 μmol·m⁻²·s⁻¹ uncertainty) |
| Flow Measurement | Glass Rotameter |
| Chamber Dimensions | Standard 55 × 20 mm (customizable) |
| Operating Environment | 20–50 °C, 0–90% RH (non-condensing) |
| Power | DC 7.4 V Li-ion battery (10 h continuous operation) |
| Data Storage | 2 GB microSD card |
| Display | 320 × 160 pixel monochrome LCD with Chinese UI |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (host only) |
| Brand | Tlyon |
|---|---|
| Model | Tlyon-1024 |
| Origin | Sichuan, China |
| CO₂ Analysis | NDIR, 0–10,000 ppm (μmol·mol⁻¹), Resolution: 0.1 ppm |
| CO₂ Accuracy | ±0.5 ppm (0–3,000 ppm) |
| Leaf Temperature Sensor | Pt100 RTD, Range: −20–60 °C, Accuracy: ±0.2 °C |
| Chamber Temperature Sensor | Heraeus digital thermistor, Range: −20–80 °C, Accuracy: ±0.2 °C |
| Relative Humidity Sensor | Swiss-made capacitive sensor, Range: 0–100% RH, Accuracy: ≤±1% RH |
| PAR Sensor | Calibrated silicon photodiode with 400–700 nm bandpass filter, Range: 0–3,000 μmol·m⁻²·s⁻¹, Accuracy: <±1 μmol·m⁻²·s⁻¹ |
| Flow Control | Adjustable micro-flowmeter, Max flow: 1.5 L·min⁻¹, Accuracy: ±1% (0.2–1 L·min⁻¹: ±0.2%) |
| Data Storage | Internal flash memory (unlimited capacity) |
| Display | 5″ TFT color touchscreen, 800×480 resolution |
| Dimensions | 255×255×110 mm |
| Weight | 3.8 kg (main unit) |
| Leaf chamber options | Type I (25×25 mm), Type II (55×20 mm), Type III (65×10 mm, standard) |
| Power | Rechargeable Li-ion battery, >12 h continuous operation |
| Operating Environment | −20–60 °C, 0–100% RH (non-condensing) |
| Brand | TLYON |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TLYON-FJ-30L |
| Price Range | USD 14,000–28,000 |
| Vessel Volume | 30 L |
| Aeration System | Quad-channel gas mixing and sterile air delivery system |
| pH Control | 0–14 pH (display), ±0.01 pH resolution, auto-setpoint control |
| Dissolved Oxygen (DO) Control | 0–200% saturation (display), 0.1% resolution |
| Temperature Control | 0–150 °C (measurement), ±0.2 °C accuracy, 0.1 °C resolution |
| Working Pressure | 0.3 MPa |
| Vessel Material | ASTM A240 316 stainless steel |
| Sterile Air Filtration | Triple-stage membrane filtration (5 µm pre-filter, 0.1 µm primary, 0.01 µm final |
| Feed System | Peristaltic pump with constant-flow precision |
| Antifoam Control | Conductivity-based automatic dosing module (10–100,000 Ω range) |
| Biogas Measurement | BMP gas volume detection (0–5000 mL/h, ±0.01 mL error, 6.5 mL resolution) and real-time gas flow rate monitoring (0–10 L/min, ±0.1% FS accuracy, 0.01 mL/min resolution) |
| Control Architecture | MC-BIO8000 embedded PLC-based lower-level controller + PC-based upper-level HMI with audit trail and data logging |
| Brand | Tlyon |
|---|---|
| Model | Tlyon-WinRHIZO |
| Origin | Sichuan, China |
| Instrument Type | High-Resolution Flatbed Scanner-Based Root Image Analysis System |
| Software Editions | Basic / Standard / Professional |
| Image Input Formats | TIFF, JPEG |
| Calibration | Scanner-specific .cal file + hardware dual-source illumination |
| Minimum PC Requirements | Pentium III, 64 MB RAM, 17" display |
| Compliance | Designed for GLP-aligned root phenotyping workflows |