UGT
Filter
Showing all 11 results
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | ECOLAB FLEX |
| Configuration | Modular Soil Unit + Atmospheric Unit + Central Control & Data Acquisition Unit |
| Compliance | Designed for GLP-compliant environmental research and ISO 14040/14044 life cycle assessment studies |
| Sensor Integration | Supports analog/digital (SDI-12, RS-485, 0–10 V, 4–20 mA) interfaces for third-party and OEM sensors |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | ECOCLIM |
| Temperature Control Range (Upper Zone) | −2 °C to +30 °C |
| Relative Humidity Range (Upper Zone) | 45–85 % RH |
| Temperature Control Range (Lower Zone) | −10 °C to +40 °C |
| CO₂ Control | Yes |
| Lighting System | True Daylight PLUS LED Panels (CRI ≥ 96) |
| Dimming Range | 1–100 % per channel |
| User Interface | 12-inch capacitive touchscreen |
| Alarm Notification | Email and SMS alerts |
| Sample Compartment Configuration | Upper growth chamber + lower zone with six lysimeter mounting positions |
| Compliance | Designed for GLP-compliant plant phenotyping workflows |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | 800 |
| Instrument Type | Multifunctional Soil Evapotranspirometer |
| Compliance | OIML Class C3, IP68 |
| Weighing Resolution | 0.01 mm |
| Groundwater Control Precision | ±1 cm |
| Data Acquisition | DL-105 (32-channel, 15-bit ADC, 512 kB RAM) |
| Soil Sensors | UMP-1 (VWC: 0–100%, ±2% acc. |
| Temp | −40–60 °C, ±0.2 °C |
| EC | 0–4 mS/cm, ±0.1% acc.), Tensio160 (Tension: +25 to −85 kPa, ±0.3 kPa) |
| Structural Material | HDPE chamber (200 cm H × 40 mm wall, 1500 kg), Stainless steel column (1 m² surface area, 170 cm H, 8 mm wall) |
| Filtration | Triple-layer bottom filter (0.1–0.5 mm / 0.71–1.25 mm / 3.15–5.60 mm) |
| Software | UGT-Log v5.x (parameter configuration, real-time visualization, time-series export, audit-trail enabled) |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | FOG II |
| Measurement Principle | Pressure-based CO₂ evolution from HCl–CaCO₃ reaction |
| Display | Backlit LCD with membrane keypad |
| Power | 3×AA alkaline or rechargeable batteries |
| Measurement Range | 0–100% CaCO₃ (w/w) |
| Accuracy | ±0.5% CaCO₃ |
| Resolution | 0.1% CaCO₃ |
| Linearity (r²) | ≥0.999 |
| Temperature Compensation | Built-in sensor, 5–50 °C |
| Sample Mass | 0.5–5 g |
| Analysis Time | ~30 s per sample |
| Data Storage | Last 50 measurements |
| Ingress Protection | IP65 |
| Dimensions (L×W×H) | 200×94×39 mm |
| Weight | 350 g |
| Housing Material | UL 94 HB-rated ABS |
| Keypad | Polyester (PET) membrane |
| Display Coating | Scratch-resistant resin |
| Standard Kit | Analyzer unit, glass reaction vials, 100 mL sampling bottle, silicone tubing, precision micro-scale (0.01 g resolution), batteries, operation manual, and rugged carry case |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | Ku-pF |
| Instrument Type | Soil Water Potential and Moisture Characterization System |
| Sample Capacity | 10 columns |
| Column Volume | 250 cm³ |
| Cross-sectional Area | 41 cm² |
| Weighing Resolution | 0.01 g |
| Matric Potential Range | +100 to −85 kPa (pF 2.0–2.8) |
| Hydraulic Conductivity Range | kᵤ < 10 cm/d |
| Measurement Interval | 10–40 min |
| System Dimensions | 100 × 70 × 40 cm |
| Weight | 40 kg |
| Power Supply | 220 V / 1 A |
| Interface | USB |
| Typical Test Duration | 2–10 days |
| Compliance | ASTM D6836, ISO 11274, UNSODA-compatible data export |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | PPE |
| Application | Non-invasive, whole-plant water potential and transpiration rate measurement under controlled environmental conditions |
| Measurement Principle | Pressure chamber-based equilibrium pressure differential (for water potential) and dynamic humidity gradient analysis (for transpiration rate) |
| Environmental Control | Adjustable photosynthetic photon flux density (PPFD), air relative humidity, soil moisture status |
| Integrated Sensors | PAR sensor, high-precision capacitive humidity sensors (in/out), thermocouple-based temperature differentials, CO₂ infrared gas analyzer (for respiration rate) |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | RTG |
| Type | Portable Weighing Lysimeter |
| Cylinder Dimensions (D×H) | 300/500/800 mm × 300/600/900 mm |
| Weighing Resolution | 0.01 mm |
| Tensiometer Range | 0–1500 kPa (pF 0–4.2) |
| Soil Moisture Sensor (SM100) | 0–60 % vol, ±3 % accuracy |
| Data Logger | 16-channel, 15-bit ADC, 512 kB RAM |
| Compliance | ISO 10381-3, ASTM D5887, FAO Irrigation and Drainage Paper No. 56 |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | Run-off |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| Key Components | V2A Diversion Unit, Dual-Bucket Flowmeters (3 L & 1 L), 24-Bottle Auto-Sampler, UMP-2 Multi-Parameter Soil Sensor (VWC/Temp/EC), Tipping-Bucket Rain Gauge (2 mL per tip, 0.1 mm resolution), Data Logger (15-bit ADC, 512 KB RAM, 8-channel, programmable sampling logic) |
| Compliance | Designed for ISO 11274 (soil water retention), ASTM D4959 (soil moisture by capacitance), and EU Water Framework Directive (WFD) monitoring protocols |
| Software | UGTLOG v5.x (Windows-based, supports audit trail, parameter scheduling, event-triggered sampling, and export to CSV/Excel) |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | SEDIMAT 4-12 |
| Standard Compliance | DIN ISO 11277, ASTM D422 (optional) |
| Sample Capacity | 12 samples per run |
| Fractionation Levels | 4 (F1–F4) or 2 (ASTM F1–F2) |
| Temperature Control | Precise 25 °C water bath |
| Automation | 4-axis robotic arm (X: 1290 mm, Y: 990 mm, Z1 stirring: 790 mm, Z2 pipetting: 490 mm) |
| Dimensions (L×W×H) | 2080 × 860 × 1940 mm |
| Weight | ~400 kg |
| Power Supply | CEE 16, 16 A, 3N/PE, AC 380 V / 50 Hz |
| Pipetting Accuracy | Depth- and time-synchronized sampling per ISO-defined intervals |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SUSTRA Aeolian Erosion Monitoring System |
| Pricing | Upon Request |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | UMP-2 |
| Power Supply | 6–24 V DC |
| Current Consumption | 60 mA |
| Volumetric Water Content Range | 0–100 %vol |
| Accuracy (VWC) | ±2 %vol |
| Resolution (VWC) | 0.1 %vol |
| EC Range | 0.001–5 mS/cm (up to 40 mS/cm at reduced resolution) |
| EC Accuracy | ±1 % |
| Temperature Range | −40 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Output Signals | Three analog outputs (0–1 V for temperature, EC, and VWC respectively) + RS485 digital interface |
| Connector | M12 with 1.5 m integrated cable |
| Enclosure | Fully potted, IP68-rated |
| Installation | Direct burial or horizontal embedding |