VELP
Filter
Showing 1–30 of 104 results
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Ermes |
| Software Type | Mass Spectrometry–Compatible LIMS Platform |
| Deployment | Web-Based SaaS |
| Compliance Framework | Supports GLP/GMP-aligned data integrity principles |
| Remote Control Protocol | HTTPS-secured RESTful API |
| User Access | Role-based multi-user web interface (PC, tablet, mobile) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | WIZARD |
| Speed Range | 0–3000 rpm |
| Operation Modes | Continuous & Touch-Activated |
| Motion Type | Circular Orbital |
| Amplitude | 4.5 mm |
| Display/Control | Analog Speed Knob |
| Housing Material | Zinc-Alloy Base with High-Performance Polymer Enclosure |
| IP Rating | IP42 |
| Sensor Technology | Patented Infrared Proximity Detection |
| Foot Design | Three Anti-Slip Rubber Feet |
| Voltage/Frequency | Universal Input (100–240 V, 50/60 Hz) |
| Compatibility | Tubes (0.2–50 mL), Microplates (96-/384-well), Beakers (up to 250 mL) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | JP |
| Max Air Flow Rate | 22 L/min |
| Flow Control Range | 0–22 L/min |
| Vacuum Adjustment Range | 1–0.04 bar |
| Residual Pressure at 15°C | 35 mmHg |
| Power Consumption | 160 W |
| Dimensions (W×D×H) | 250 × 400 × 370 mm |
| Weight | 8 kg |
| Housing Material | ABS |
| Electrical Supply | 230 V / 50 Hz |
| Optional Accessories | IQ/OQ Validation Documentation (P/N A00000253) |
| Certifications | CE, RoHS |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ROTAX 6.8 |
| Speed Range | 0–30 rpm (electronically adjustable) |
| Display | LCD speed indicator |
| Compliance | UNI 10802, DIN 38414 |
| Sample Capacity | up to 6 × 2 L bottles or 8 × 1 L bottles (with optional adapter) |
| Construction | chemically resistant cantilever shaft and housing |
| Safety | automatic rotation stop upon mechanical obstruction |
| Intended Use | aqueous solubility testing of pollutants |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SMS |
| Dimensions | 300 × 500 × 190 mm |
| Weight | 3.5 kg |
| Construction | Epoxy-coated stainless steel |
| Absorption Stages | Three-stage (condensation → alkaline neutralization → activated carbon adsorption) |
| Pump Type | Recirculating water-based absorption pump (JP series) |
| Vacuum Control | Adjustable |
| Optional Accessories | Replacement activated carbon packs (A00001164), activated carbon filter cartridge (A00001165), IQ/OQ validation documentation (A00000252) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | 6 Maxi-BMP |
| Sensor Type | Electronic Pressure Transducer (Mercury-Free) |
| Pressure Range | 500–2000 hPa |
| Display | 4-digit LED |
| Interface | Dual-button Control |
| Output Units | NmL CH₄/g SV and mbar |
| Test Vessel Capacity | 1000 mL |
| Max. Sensors per Databox™ | 48 |
| Data Acquisition Interval | 2 h to 48 h |
| Test Duration | 10–60 days |
| Enclosure Rating | IP54 (per EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Connectivity | USB (RESPIROSoft™) or Optional Wi-Fi (Ermes™ Cloud Platform) |
| Power | Rechargeable Battery (Long Standby) |
| Optional Module | Ermes™ Remote Monitoring & Alert System |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AM4 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 15 L × 4 positions |
| Speed Range | 40–1500 rpm |
| Temperature Range | Ambient to 370 °C |
| Heating Plate Material | Anodized Aluminum with Ceramic Coating |
| Plate Diameter per Position | 135 mm |
| Inter-center Distance Between Positions | 186 mm |
| Control System | Electronic Speed & Temperature Control with SpeedServo™ Technology |
| Drive Magnet Type | High-Power PCM (Permanent Ceramic Magnet) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Type | Magnetic Stirrer |
| Max. Stirring Volume | 15 L |
| Speed Range | 40–1500 rpm |
| Temperature Range | Ambient to 550 °C |
| External Pt100 Probe Support | Yes (up to 300 °C, ±0.5 °C accuracy) |
| Motor | Brushless |
| Control Interface | Dual rotary knobs + LED display with icon-based UI |
| Programmable Functions | Timer (1 min–99 h 59 min), Auto-reversal (5 s–99 min 59 s), Intermittent mode (5 s–99 min 59 s), Safety Lock, Audible Alerts |
| Connectivity | Embedded Wi-Fi for VELP Ermes Cloud Platform |
| Housing Material | Chemically resistant technical polymer |
| Heating Surface | Corrosion-resistant ceramic plate |
| Safety Features | “HOT” warning display (>50 °C, heater off), Spill containment groove, IP20-rated enclosure |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AREC.T |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume | 15 L (H₂O) |
| Speed Range | 0–1500 rpm |
| Temperature Range | Ambient to 550 °C |
| Heating Plate Diameter | 180 mm |
| Power Rating | 800 W |
| Display | LCD |
| Protection Class | IP42 (per CEI EN 60529) |
| Timer Range | 0–999 min |
| Housing Material | Corrosion-Resistant Construction |
| Weight | 3.3 kg |
| Dimensions | 203 × 94 × 344 mm |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AREC.X |
| Stirring Capacity | 15 L (H₂O) |
| Speed Range | 0–1500 rpm |
| Temperature Range | Ambient to 550 °C |
| Heating Plate Diameter | 180 mm |
| Power | 800 W |
| Display | LCD |
| Protection Rating | IP42 (per CEI EN 60529) |
| Weight | 3.3 kg |
| Dimensions | 203 × 94 × 344 mm |
| Temperature Accuracy | ±0.5 °C (with VTF digital thermostat), ±1.0 °C (with external Pt100 probe) |
| Max External Probe Temp | 250 °C |
| Compatible Accessories | VTF digital thermostat, Pt100 probe holder, support rod, stirring bars (6×35 mm, 9.5×60 mm, 10×40 mm), flask heating blocks (250/500/1000 mL) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L |
| Speed Range | 40–1500 rpm |
| Temperature Range | Ambient to 370 °C |
| Display | Dual Digital LED (Speed & Temp) |
| Temperature Control | External Pt100 Probe (±1.0 °C up to 250 °C) / Integrated VTF Controller (±0.5 °C up to 300 °C) |
| Heating Plate Material | CerAlTop™ (Ceramic-Coated Aluminum) |
| Safety Features | Over-Temp Cutoff, Hot-Plate Warning (Active until <50 °C), Overflow Channel, Low-CG Housing, Tilted Front Panel |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | AREX-6 Connect PRO |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L |
| Speed Range | 40–1500 rpm |
| Temperature Control Range | Ambient to 370 °C |
| Safety Certifications | IP42 |
| Temperature Sensor | Integrated Pt100 probe |
| Control Algorithm | PID-based digital temperature regulation |
| Motor Type | Brushless DC motor with SpeedServo™ torque compensation |
| Surface Material | CeAlTop™ ceramic-coated aluminum (Ø135 mm) |
| Timer Range | 1 min – 99 h |
| Direction Reversal Function | Programmable interval-based polarity switching |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BOD Sensor |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO)-Based Respirometric Method |
| Sensor Type | Mercury-Free Electronic Pressure Sensor |
| BOD Range Options | 90, 250, 600, and 1000 ppm |
| Data Logging | Automatic storage of up to 5 BOD values at 24-hour intervals |
| Display | Digital LCD readout |
| Durability | Industrial-grade sensor housing for long-term stability in lab environments |
| Compliance | Designed to support ISO 5815-1:2017 and APHA Standard Methods 5210B respirometric BOD protocols |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | BOD10 |
| Instrument Type | Laboratory |
| Measurement Principle | Pressure-based Respirometric Method (Mercury-Free Electronic Transducer) |
| Measurement Ranges | 90, 250, 600, 999 mg/L BOD₅ |
| Data Logging Interval | 24 h (5-point profile over standard 5-day incubation) |
| Operating Duration | Configurable from 1 to 28 days |
| Power Supply | Dual Lithium-Ion Batteries (2-year service life) |
| Safety Rating | IEC 61010-1 Class III |
| Ingress Protection | IP54 per EN 60529 |
| Operating Temperature | −20 °C to +65 °C |
| Weight | 80 g |
| Enclosure Material | Stainless Steel (316) with Chemical-Resistant Coating |
| Sample Capacity | Simultaneous monitoring of up to 10 samples (BOD Sensor System 10 configuration) |
| Alarm Function | Automatic out-of-range alert |
| Compliance | ASTM D5210, ISO 5815-1:2019, APHA 5210B, EU Directive 2000/60/EC (Water Framework Directive) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model Series | BOD6/20, BMS6/10 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO) Consumption Method |
| Sensor Technology | Mercury-Free Electronic Pressure Sensor |
| BOD Range Options | 90, 250, 600, 1000 ppm |
| Data Logging | Automatic storage of up to five BOD values at 24-hour intervals |
| Compliance | Designed for ISO 5815-1:2017 and ASTM D5210-92 (Standard Test Method for Determining Anaerobic Biodegradation of Organic Compounds in the Presence of Municipal Sewage) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | BODAuto 5000 |
| Principle | Pressure-difference (manometric) method |
| Measurement Range | 90–999 mg/L (extendable to 4000 mg/L via dilution) |
| Detection Limit | 90 mg/L |
| Accuracy | ±1 mg/L |
| Single-sample Analysis Time | 1 min |
| Repeatability | ±1% RSD |
| Sample Volume | 500 mL |
| Sensor Display | 3-digit LED, direct mg/L readout |
| Data Logging | Automatic BOD value storage every 24 h (up to 5 values) |
| Sensor Housing Material | High-performance polymer |
| Sensor Power | 2 × CR2430 lithium batteries (6 V total) |
| Ingress Protection | IP54 (IEC/EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Standards Conformance | ISO 5815-1:2019, Standard Method 5210D |
| Dimensions (Sensor) | 55 × 71 × 73 mm |
| Weight (Sensor) | 0.08 kg |
| Dimensions (Analyzer Unit) | 75 × 230 × 75 mm |
| Weight (Analyzer Unit) | 0.4 kg |
| Optional Configurations | 6-position and 10-position magnetic stirring systems (FOC 200E incubator compatible) |
| Accessories | Calibration kit (A00000135), Control test tablets (A00000136, 8 pcs/box) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLASSIC |
| Price | Upon Request |
| Speed Range | 0–3000 rpm |
| Operation Modes | Continuous & Touch-Activated |
| Motion Type | Circular Orbital |
| Body Material | Zinc Alloy with High-Performance Polymer Housing |
| Amplitude | 4.5 mm |
| Speed Indication | Analog Dial |
| IP Rating | IP42 |
| Foot Design | Three Non-Slip Rubber Feet |
| Voltage/Frequency | Universal Input (100–240 V, 50/60 Hz) |
| Adapter Compatibility | Wide Range for Tubes (0.2–50 mL), Microplates (96-/384-well), and Beakers |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | CN 802 |
| Detection Principle | High-Temperature Combustion + NDIR & TCD Detection |
| Sample Throughput | 3–4 min per sample |
| Detection Limits | 0.01 mg C, 0.001 mg N |
| Precision | RSD < 0.5% (EDTA) |
| Sample Mass Range | 200 mg – 1 g |
| Carrier Gas Options | He or Ar |
| Connectivity | Ethernet/Wi-Fi to VELP Ermes Cloud Platform |
| Compliance | ASTM D5373, ISO 13878, USP <28>, EN 15936, AOAC 992.23 |
| Software | VELP Ermes Suite with GLP-compliant audit trail, automatic C:N ratio calculation, and report generation |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN 802 |
| Analysis Method | High-Temperature Combustion (1030 °C) |
| Detection Principle | TCD for N, NDIR for C |
| Analysis Time | 3–4 min per sample |
| Sample Weight | Up to 1 g |
| Detection Limits | 0.001 mg N (He), 0.01 mg N (Ar), 0.01 mg C |
| Repeatability (RSD) | ≤0.5% (100 mg EDTA standard) |
| Recovery | >99.5% |
| Carrier Gas | Helium or Argon (99.999% purity, 2 bar) |
| Oxygen Purity | 99.999%, 2 bar |
| Power | 1400 W, 230 V / 50–60 Hz |
| Dimensions (W×H×D) | 655×510×410 mm (655×690×410 mm with autosampler) |
| Weight | 54 kg |
| Compliance | AOAC, AOCS, AACC, ISO, EN, CEN, EPA, IFFO |
| Connectivity | USB, RS232, Wi-Fi/Ethernet to VELP Ermes Cloud Platform |
| Software | CN802 Control & Analysis Suite with GLP-compliant audit trail, real-time graphing, automated C/N ratio calculation, and report generation |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Detection Principle | High-Temperature Combustion (Dumas Method) coupled with NDIR CO₂ detection and TCD N₂ detection |
| Sample Throughput | Up to 30 samples unattended |
| Sample Form | Solid and liquid (up to 1 g) |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Detection Technologies | NDIR for CO₂, LoGas™ TCD for N₂ |
| Moisture Removal | DriStep™ integrated desiccant system |
| Automation | 30-position autosampler (expandable to 90 positions with additional trays) |
| Software Platform | CNSoft™ + Ermes Cloud Connectivity |
| Regulatory Support | Audit trail, user management, electronic signatures (21 CFR Part 11 ready) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Analysis Principle | Dumas Combustion Method |
| Measurement Range | 0.001–200 mg N (equivalent to ppm–100% N in sample) |
| Sample Weight | 200 mg–1 g |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability | RSD < 0.5% (verified with EDTA reference standard) |
| Detection Limits | 0.01 mg C, 0.001 mg N |
| Recovery Rate | >99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 655 × 510 × 410 mm |
| Carrier Gas Options | Helium or Argon (dual-gas system, no hardware modification required) |
| Compliance | Designed for GLP/GMP environments |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CSF 6 |
| Price Range | USD 13,500 – 27,000 |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | CSF6-GDE |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43 and AOAC 2009.01 |
| Sample Capacity | 6 independent positions (CSF6) + 6-position magnetic stirring (GDE) |
| Filtration System | Vacuum-assisted with adjustable vacuum control and gas-backflush |
| Digestion System | Immersion-heated water bath with ±0.2 °C temperature stability, programmable time/temperature profiles |
| Compliance | AOAC Official Methods 991.43 (Total Dietary Fiber), 2009.01 (Soluble/Insoluble Dietary Fiber), and ISO 13905 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DK 20 Digester System |
| Max Temperature | 450 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Capacity | 20 × 250 mL tubes (Ø42 mm) |
| Heating Block Material | Anodized aluminum |
| Housing Material | Stainless steel |
| Power Consumption | 13% lower than previous generation |
| Interface | 4-button digital control panel with tilted, chemically resistant front display |
| Optional Accessories | COD support rack, KS 1000 fume neutralizer |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Instrument Type | Electric Heating Digestion Instrument |
| Automation Level | Semi-Automatic |
| Digestion Positions | 20 |
| Max. Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Block Material | Aluminum Alloy |
| Reagent Channels | 20 |
| Programmable Methods | 20 user-editable methods, up to 4 ramp stages per method |
| Digestion Time Range | 1–999 min (1-min increments) |
| Display | Digital °C/°F |
| Interface | RS232 |
| Safety Features | Overtemperature Protection, Probe Fault Detection with Audible Alert |
| Compliance | Designed for GLP/GMP environments |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DKL Series |
| Instrument Type | Kjeldahl Digestion Unit |
| Max Operating Temperature | 450 °C |
| Temperature Accuracy | ±0.5 °C |
| Ramp Time to 450 °C | 22 min |
| Programmable Steps | 54 |
| Heating Module | Anodized Aluminum Block |
| Digestion Tube Compatibility | DKL8 (250 mL, Ø42 mm), DKL12 (250/400 mL, Ø42 mm), DKL20 (250 mL, Ø42 mm), DKL42 (100 mL, Ø26 mm) |
| Automation Level | Fully Automatic (Digestion + Cooling + End-of-Process Alert) |
| User Interface | Detached LCD Display |
| Unique Technology | VELP TEMS™ (Time, Energy, Money, Space Optimization) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DKL Series |
| Heating Temperature Range | Room Temperature to 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Programmable Heating Profiles | 54 Predefined + 24 User-Defined |
| Heating Ramp Stages | 4 |
| Heating Duration | 0–999 min |
| Automatic Lift Arm | Yes |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Display Interface | Multilingual (including Chinese) |
| Available Configurations | DKL8 (8-position), DKL12 (12-position), DKL20 (20-position), DKL42 (42-position) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | DKL |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | 20 |
| Max Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Module | Aluminum Block |
| Reagent Channels | 20 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ECO 8 / ECO 25 |
| Instrument Type | Laboratory Benchtop Digestion Unit |
| Measurement Principle | Closed-Tube Thermal Oxidation (Dichromate Reflux Method) |
| Wavelength for Photometric COD Readout | 610 ± 20 nm (requires compatible spectrophotometer) |
| COD Range | 10–5000 mg/L O₂ |
| Accuracy | ±0.5 mg/L (at low range), ±3% (full scale) |
| Repeatability | ±0.5% RSD |
| LOD | 0.1 mg/L |
| Digestion Time Programmable | 0–199 min or continuous mode |
| Batch Capacity | 8 or 25 samples simultaneously |
| Operating Temperatures | 70, 100, 120, 150, 160 °C (user-selectable, PID-controlled) |
| Safety Features | Transparent polycarbonate lid with overheat cut-off, auto-shutdown after cycle completion, thermal insulation housing |
| Optional Accessory | Alphanumeric tube extractor for ECO 25 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ECO |
| Instrument Type | Laboratory Digestion Block |
| Digestion Principle | Standard 2-hour Closed-Vessel Oxidation (DIN 38409-H41, ISO 6060, APHA 5220C) |
| Temperature Range | Ambient to 200 °C |
| Thermal Stability | ±0.5 °C (ECO 6/16), ±0.3 °C (ECO 8/25) at 150 °C |
| Heating Time Programmable | 0–199 min |
| Sample Volume Capacity | Up to 200 mL per vial (ECO 6) |
| Batch Capacity | 6 / 8 / 16 / 25 positions |
| Construction | Powder-coated steel housing with chemical-resistant epoxy finish |
| Safety Features | Dual independent overtemperature protection, auto-shutdown on cycle completion, audible end-of-cycle alarm |
| Compliance | Designed for use with EPA Method 410.4, ISO 6060, and DIN 38409-H41 workflows |