VELP
Filter
Showing 61–90 of 104 results
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA 701/702 |
| Principle | Dumas Combustion Method |
| Detection Limit | NDA 701: 0.003 mg N (He) |
| NDA 702 | 0.001 mg N (He) or 0.01 mg N (Ar) |
| Analysis Time | 3–4 min per sample |
| Repeatability (RSD) | <0.5% using EDTA standard (9.57% N) |
| Sample Weight | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 1400 W |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 54 kg |
| Carrier Gas | He (≥99.999%) or Ar (≥99.999%) |
| Oxygen Supply | O₂ (≥99.999%, 2 bar) |
| Combustion Temperature | 1030 °C |
| Detector | Auto-calibrating Thermal Conductivity Detector (TCD) |
| Throughput | Up to 117 samples (4 × 30-position auto-samplers) |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, EN ISO 16634-1/-2, USP <285>, FDA 21 CFR Part 11 ready (with Ermes software license) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA701 |
| Analysis Method | Dumas combustion |
| Automation Level | Fully automated |
| Detection Limit | 0.003 mg N |
| Reproducibility (RSD) | < 0.5% |
| Recovery | > 99.5% |
| Combustion Temperature | 1030 °C |
| Sample Weight Capacity | up to 1 g |
| Autosampler Capacity | up to 116 samples |
| Carrier Gas | Helium (99.999% purity, 3 bar) |
| Oxygen Supply | 99.999% purity, 3 bar |
| Auxiliary Gas | Compressed air or nitrogen (99.6%, oil- and water-free, 4 bar) |
| Power Consumption | 1400 W |
| Dimensions (W×H×D) | 655 × 510 × 410 mm (655 × 690 × 410 mm with autosampler) |
| Weight | 54 kg |
| Interfaces | USB, RS232 |
| Compliance | AOAC, AACC, ASBC, ISO 14891, OIV |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Repeatability | < 0.1% |
| Recovery Rate | > 99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 655 × 510 × 410 mm |
| Weight | 54 kg |
| Voltage/Frequency | 230 V / 50–60 Hz |
| Compliance | ASTM D5623, ISO 14891, AOAC 992.15, EN ISO 16634-1 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Analysis Principle | Dumas Combustion Method |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability (RSD) | < 0.5% |
| Recovery Rate | > 99.5% |
| Detection Limit | 0.001 mg N (He), 0.01 mg N (Ar) |
| Combustion Temperature | 1030 °C |
| Power Consumption | 1400 W |
| Auto-sampler Capacity | Up to 117 positions (4 trays × 30 positions) |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 55 kg |
| Electrical Supply | 230 V / 50 Hz |
| Gas Purity Requirement | ≥99.999% for He/Ar and O₂ |
| Gas Pressure Requirement | 2 bar for carrier gas and O₂ |
| Detector | Calibrated Thermal Conductivity Detector (TCD), reference-gas-free operation |
| Sample Mass Range | Up to 1.0 g |
| Data Interfaces | USB, RS232 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Detection Principle | High-Temperature Combustion (Dumas Method) |
| Carrier Gases | Helium and Argon (switchable without hardware/software modification) |
| Analysis Time | ~3–4 min per sample |
| Automation Level | Fully Automated, Unattended Operation |
| Compliance | GLP-compliant architecture, TEMS™ certified design |
| Sample Forms | Solid and liquid matrices |
| Reagent Requirement | None (dry chemistry method) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OHS 200 Advance |
| Instrument Type | Electric Overhead Stirrer |
| Max. Mixing Volume | 25 L |
| Speed Range | 50–2000 rpm |
| Temperature Control Range | 5–40 °C |
| Torque | 200 N·cm |
| Max. Viscosity Handling | 100,000 mPa·s |
| Display | 3.5″ TFT touchscreen |
| Safety Rating | IP54 |
| Motor Type | Brushless DC with SpeedServo™ torque compensation |
| Timer | 1 min – 99 h 59 min |
| Connectivity | Wi-Fi (VELP Ermes Cloud), USB (ControllerSoft™) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OV5 |
| Instrument Type | Probe-Type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 70×255×70 mm |
| Maximum Processing Volume | 40 L (water) |
| Speed Range | 10,000–30,000 rpm |
| Maximum Viscosity Handling | 10,000 mPa·s |
| Shaft Material | Stainless Steel with PTFE Seals |
| Safety Features | Overload Protection, Soft-Start Motor, Interlocked Safety Switch |
| Rotor-Stator Assembly | Tool-Free Quick-Connect via Snap Hook Mechanism |
| Compliance | CE-marked, Designed for GLP-Compatible Laboratories |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OXITEST |
| Instrument Type | Accelerated Oxidation Stability Analyzer |
| Pressure Range | 0–8 bar |
| Temperature Range | Ambient to 110 °C |
| Sample Volume | 100 mL per chamber |
| Power Consumption | 900 W |
| Voltage | 230 V / 50–60 Hz |
| Dimensions (L×W×H) | 365 × 190 × 485 mm |
| Weight | 16.5 kg |
| Safety Features | Integrated safety vacuum tube, visual over-temperature alarm, real-time fault indication |
| Compliance | CE-marked, IEC-compliant, ISO 9001 / ISO 14001 / ISO 45001 (formerly OHSAS 18001) certified |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OXITEST |
| Pricing | Upon Request |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OXITEST |
| Reaction Vessels | 2 |
| Single Vessel Volume | 100 mL |
| Pressure Range | 0–8 bar |
| Temperature Range | Ambient to 120 °C |
| Temperature Setpoint Accuracy | ≤ ±0.5 °C |
| Temperature Reproducibility | ≤ ±0.2 °C |
| Power Consumption | 900 W |
| Voltage | 115 V / 60 Hz or 230 V / 50–60 Hz |
| Dimensions (W×D×H) | 365 × 190 × 485 mm |
| Weight | 16.5 kg |
| Interface | USB, LAN, Wi-Fi |
| Safety Features | Overpressure relief valve, overtemperature cutoff, visual fault alerts |
| Compliance | AOCS Cd 12c-16 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Radiation |
| Detection Principle | Geiger-Müller Tube with Mica End-Window |
| Measuring Ranges | 0.5–5.0–50 mR/h (three auto-ranging scales) |
| Alpha Energy Range | up to 2.5 MeV (≥80% detection efficiency at 3.5 MeV) |
| Beta Energy Threshold | ≥150 keV (75% efficiency) |
| Gamma/X-ray Sensitivity | ≥10 keV through mica window |
| Power Supply | 9 V alkaline battery (typical 2000 h operation) |
| Display | Analog needle meter with LED visual alarm and audible buzzer |
| Weight | 0.25 kg |
| Compliance | CE-marked, compliant with IEC 60846-1:2014 for portable radiation survey meters |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | BOD |
| Pressure Range | 500–2000 mbar (hPa) |
| BOD Range | 90–4000 mg/L (dilutable) |
| Display | 4-digit LED |
| Interface | Dual-button |
| Wireless Data Transmission | Yes |
| Software | RESPIROSoft™ & DataBox™ |
| Cloud Integration | VELP Ermes Platform |
| Battery-Powered Operation | Yes |
| Compliance | Designed for ISO 5815-1, ASTM D5210, APHA 5210B |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Respirometric Sensor System 6 |
| Pressure Range | 500–2000 hPa |
| Sensor Count | 6 |
| Test Vessel Capacity | 1000 mL |
| Data Acquisition Interval | 10 min – 48 h |
| Test Duration | 1–180 days |
| Stirrer Speed Control | 6-digit digital setting with lock function |
| Sensor Power | 2 W |
| Battery Type | CR2430 |
| Sensor Dimensions | 50 × 70 × 70 mm |
| Sensor Weight | 80 g |
| Stirrer Unit Dimensions | 230 × 51.5 × 370 mm |
| Stirrer Unit Weight | 1.75 kg |
| Ingress Protection | IP54 (EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Databox™ Capacity | up to 48 sensors (8 systems × 6 sensors) |
| Connectivity | USB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform) |
| Software | RESPIROSoft™ v5.x with audit trail, method templates, report generation, and battery-level monitoring |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | RESPIROMETRIC |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 90–999 mg/L O₂ demand |
| Detection Limit | 90 mg/L |
| Accuracy | ±1 mg/L |
| Single-Sample Measurement Time | 1 min |
| Repeatability | ±1% |
| Pressure Sensing Range | 500–2000 mbar |
| Sample Throughput | Up to 48 vessels simultaneously |
| Data Transmission | Wireless (via DataBox™) |
| Software Integration | RESPIROSOFT™ |
| Optional Cloud Platform | Ermes™ |
| Compliance | Designed for ASTM D5210, ISO 10707, ISO 11734, ISO 14852, and OECD 301 series testing protocols |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | RESPIROMETRIC System 6 |
| Sensor Type | Electronic pressure sensor (mercury-free) |
| Pressure Range | 500–2000 hPa |
| Display | 4-digit LED |
| Stirring Control | 6-digit programmable stirrer with speed lock |
| Power | 2 W |
| Sensor Dimensions | 50 × 70 × 70 mm |
| Battery | CR2430 |
| Ingress Protection | IP54 per EN 60529 |
| Safety Compliance | IEC/EN 61010-1 |
| Test Vessel Capacity | 1000 mL |
| Data Acquisition Interval | 10 min – 48 h |
| Test Duration | 1–180 days |
| Databox™ Capacity | up to 48 sensors (8 systems × 6 sensors) |
| Connectivity | USB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform) |
| Data Storage | Local (sensor), PC (RESPIROSoft™), or cloud (Ermes™) |
| Optional Module | Ermes™ Cloud Platform for remote monitoring, multi-device access (PC/tablet/smartphone), real-time alerts (in-app/email), and collaborative reporting |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ROTAX 6.8 |
| Power Supply | 115 V / 230 V, 50–60 Hz |
| Rated Power | 100 W |
| Speed Range | 0–30 rpm |
| Display | LCD |
| Sample Capacity | 6 × 2 L bottles or 8 × 1 L bottles |
| Bottle Compatibility | 2 L PE bottles (H: 220–280 mm, Ø ≤ 135 mm) |
| 1 L PE bottles (H | 200–270 mm, Ø ≤ 110 mm) |
| Dimensions (W×H×D) | 665 × 520 × 470 mm |
| Weight | 30 kg |
| Construction | Epoxy-coated metal frame |
| Accessories Available | Polyethylene bottles (1 L / 2 L), 8-position 1 L bottle adapter (2 pcs/box), round glass bottle caps (2 L) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ROTAX6.8 |
| Capacity | 6 × 2 L bottles or 8 × 1 L bottles |
| Rotation Speed | 0–30 rpm |
| Bottle Height Range | 205–270 mm |
| Max Bottle Diameter | 135 mm |
| Display | LCD |
| Power Consumption | 100 W |
| Net Weight | 30 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 148 |
| Extraction Chamber Volume | 150 mL |
| Receiver Flask Volume | 100 mL |
| Temperature Range | 100–260 °C |
| Temperature Control Accuracy | ±1 °C |
| Channel Capacity | 3 or 6 positions |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 158 |
| Configuration | 3-channel or 6-channel |
| Compliance | AOAC, ISO 1443, ISO 6497, EPA 907.1, APHA 2710B, UNI EN 14082 |
| Solvent Recovery Rate | >90% |
| Safety Certification | CE |
| Heating Control | PID-regulated electric heating elements with TEMS™ thermal energy management system |
| Sample Handling | Fully automated Randall extraction cycle with SafeEnd™ overheat protection and SolventXpress™ solvent delivery |
| Data Management | Onboard LCD touchscreen interface with audit-trail-capable result storage and GLP-compliant reporting |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 158 |
| Extraction Type | Solid-Liquid |
| Max Temperature | 380 °C |
| Operating Pressure | Ambient |
| Extraction Cell Volume | 250 mL |
| Cycle Time | 130 min |
| Dimensions (W×H×D) | 358×546×450 mm (SER 158/3) / 546×546×450 mm (SER 158/6) |
| Sample Positions | 3 or 6 |
| Solvent Recovery Rate | >90% |
| RSD | ≤1% |
| Measurement Range | 0.1–100% |
| Power Supply | 115/230 V, 50/60 Hz |
| Power Consumption | 630/850 W |
| Cooling Water Flow | ≥1 L/min |
| Display | 7-inch color touchscreen |
| Connectivity | 3×USB, Ethernet, Ermes Cloud Platform |
| Compliance | ASTM D2231, ISO 14465, AOAC 920.39, USP <467>, EN 14082, NF T90-107 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER148 |
| Extraction Channels | 6 |
| Sample Capacity per Channel | 0.5–15 g |
| Reproducibility | ±1% |
| Solvent Volume Range | 30–100 mL |
| Solvent Recovery Rate | 50–75% |
| Temperature Control Range | 100–260 °C |
| Immersion Time | 0–999 min |
| Washing Time | 0–999 min |
| Power Consumption | 900 W |
| Net Weight | 40 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER148/3 |
| Protection Rating | IP55 |
| Compliance | CEI EN 60529, GLP |
| Control System | Dual-zone microprocessor with 29 pre-programmed methods |
| Safety Features | Coolant leak detection alarm |
| Output | Data logging and print capability |
| Sample Capacity | 3 positions per batch |
| Extraction Principle | Sequential Randall extraction (immersion → reflux rinsing → solvent recovery via distillation) |
| Application Scope | Solid and semi-solid matrices |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER148/6 |
| Extraction Channels | 6 |
| Solvent Recovery System | Dual-stage condensation & distillation-based |
| Safety Features | Coolant leak detection alarm |
| Control System | Dual-zone microprocessor with 29 pre-programmed methods |
| Display | Dual-line LCD showing real-time temperature and remaining time |
| Data Output | Print or save extraction logs |
| Sample Format | Solid or semi-solid matrices in filter thimbles |
| Compliance | Designed for ASTM D2231, ISO 1443, AOAC 920.39, USP <467>, and GLP-compliant workflows |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER158 |
| Extraction Chamber Volumes | 140 mL, 195 mL, 260 mL (selectable) |
| Receiver Bottle Volume | 1 L |
| Temperature Range | up to 380 °C |
| Temperature Control Accuracy | ±1 °C |
| Number of Channels | 3 or 6 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER158 |
| Application Category | Fully Automated Protein and Fat Determination Instrument |
| Extraction Principle | Randall Continuous Extraction Technology |
| Compliance Standards | AOAC 920.39, ISO 1443, ISO 6496, EPA 3541, APHA 5520E, UNI EN ISO 1443 |
| Safety Certification | CE, IEC 61010-1 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TB1 |
| Type | Portable |
| Measurement Range | 0–1000 NTU |
| Repeatability | ±0.01 NTU or ±1% of reading (higher repeatability for gel samples) |
| Light Source | Infrared LED (850 nm) |
| Detection Angle | 90° (ISO 7027 compliant) |
| IP Rating | IP67 (waterproof) |
| Weight | 200 g |
| Dimensions | 68 × 50 × 155 mm |
| Calibration | Single-point using standard reference solutions (e.g., Formazin or StablCal) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TB1 |
| Battery Life | Up to 1200 Measurements per Set |
| Measurement Range | 0.02–800 NTU |
| Detector | Silicon Photodiode |
| Light Source | Near-Infrared LED (850 nm) |
| Sample Cell | 25 mm Round Cuvettes (3 included) |
| Housing | Impact-Resistant ABS |
| Accessories | Calibration Cloth, Silicone Oil, Carrying Case, AA Batteries (4) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TMD6 |
| Dimensions (W×H×D) | 225 × 810 × 126 mm |
| Weight | 5 kg |
| Compatible Digestion Tubes | Φ42 × 300 mm, Φ42 × 250 mm |
| Condenser Type | Allihn reflux condenser (accessory code 10000000) |
| Absorption Accessory | Code 10000001 |
| Condenser Mounting Kit | Code 10000002 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TX4 |
| Speed Range | 0–3000 rpm |
| Operating Modes | Continuous & Touch-Activated |
| Motion Type | Circular Orbital |
| Amplitude | 4.5 mm |
| Display | Digital LCD (Large, Backlit) |
| Control Interface | Infrared Sensor (Patented, Contactless Activation) |
| Housing Material | Zinc Alloy |
| Base | Non-Slip Rubber Feet |
| Ingress Protection | IP42 |
| Voltage/Frequency | As per regional model specifications |
| Accessories Compatibility | Tubes (0.2–50 mL), Microplates, Flasks, Vials |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 129 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Determination Range | 0.1–200 mg |
| Distillation Time | 3–5 min per sample |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤5 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 385×416×780 mm |