York Instrument
Filter
Showing all 23 results
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Type | Imported |
| Model | AngleStar® Series |
| Power Supply | 9 V DC battery (or external DC source) |
| Cable Length | Standard 4 ft (1.2 m), up to 200 ft (61 m) |
| Operating Temperature | –18 °C to 55 °C |
| Linear Range Options | ±20°, ±45°, or 0–90° |
| Resolution | 0.01° (high-res ±20° model) or 0.1° (±45°/0–90° models) |
| Linearity | ±0.1° (0–10°), ±1% of reading (10–45°) |
| Zero Repeatability | ±0.1° |
| Sensitivity Axis Error | <1% below 45° |
| Time Constant | 0.3 s |
| Frequency Response | 0.5 Hz |
| Cable | 4-conductor, AWG 26, PVC jacket |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPP1000-M,L |
| Price | Upon Request |
| Pressure Range | 0–100 MPa |
| Medium | Oil |
| Connection | 2 × G 1/2" Female Thread |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | KULITE BG Series |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | AccuStar |
| Output Options | Analog (0–5 V, 0–10 V, ±5 V), Ratiometric, Digital (PWM), Serial (RS-232/RS-485) |
| Full Scale Range | ±60° |
| Linear Range | ±45° |
| Resolution | 0.001° |
| Accuracy (0–10°) | ±0.1° |
| Accuracy (10–45°) | ±1% of reading |
| Zero Repeatability | 0.05° |
| Cross-Axis Sensitivity | <1% (within ±45°) |
| Time Constant | 0.3 s |
| Frequency Response (−3 dB) | 0.5 Hz |
| RF Immunity | <±2° |
| Operating Temperature | −30°C to +65°C |
| Storage Temperature | −55°C to +65°C |
| Zero Tempco | 0.008°/°C |
| Scale Factor Tempco | 0.1%/°C |
| EMC Compliance | EN 55022 Class B, IEC 61000-4-2 Level 2 (ESD), IEC 61000-4-3 Level 3 (10 V/m), IEC 61000-4-4 Level 3 (2 kV), MIL-STD-461D CS114 |
| Enclosure | Robust plastic housing, Ø2 in, Weight: 2 oz |
| Certifications | CE |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Type | DP-45 |
| Measurement Range | ±45° |
| Resolution | ±0.1° |
| Linearity | ±0.1° (0–10°), ±1.5% of reading (10–45°) |
| Repeatability | ±0.1° |
| Sensitivity Axis Error | <1% at tilt angles <45° |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~100 hours |
| Operating Temperature | 0–65°C |
| Storage Temperature | −40–65°C |
| Weight | 349 g (12.3 oz) |
| Housing | Compact molded plastic enclosure |
| Reference Mode | Adjustable zero (floating reference) |
| Hold Function | Yes |
| Low-Battery Indication | LO BAT display at <7 V |
| Over-Range Indication | Flashing “OVER RANGE” beyond ±45° |
| Sign Convention | Minus sign (−) indicates counterclockwise deviation from reference |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CEP6000 |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC2000 |
| Control Principle | Electronic Pressure Control |
| Display Type | Digital |
| Pressure Control Range | 0.1–100 kPa |
| Accuracy | ±0.1 % FS |
| Integrated Automatic Pressure Source | Yes |
| Power Options | AC Adapter or Rechargeable Li-ion Battery |
| Zeroing | Automatic On Startup |
| Communication Interfaces | RS-232, USB |
| Compliance Certifications | Factory Calibration Certificate Included |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPC6050 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.003 % FS (typical 0.001 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Control Response Time | < 10 s |
| Accuracy | ±0.01 % of reading (upper half of span, IS-50 compliant) |
| Uncertainty Budget | k=2, includes instrument intrinsic performance, reference standard uncertainty, long-term stability, environmental effects, zero-drift beyond auto-compensation range, and temperature influence |
| Calibration Interval | 180 days for gauge/absolute pressures ≤ 0.1 MPa and bidirectional ranges ≤ 1 MPa |
| Sensor Recommendation | Absolute pressure sensor preferred for pressure simulation to enable effective zero-point drift compensation |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC8000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD with Capacitive Glass Touchscreen |
| Pressure Control Range | Up to 40 MPa |
| Control Stability | 0.002% FS |
| Pressure Types | Gauge (Positive/Negative), Absolute |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | CPC8000-H |
| Pricing | Upon Request |
| Pressure Range | 60 / 100 / 160 MPa |
| Pressure Medium | Hydraulic Oil or Water |
| Control Stability | 0.003 % FS |
| Accuracy | 0.01 % FS |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPP30 |
| Pricing | Upon Request |
| Pressure Range | –95 kPa to +3.5 MPa |
| Mounting Interface | G 1/2" (male) for reference gauge |
| Test Port Connection | G 1/4" internal thread via included 0.5 m test hose (CT91.06 kit) |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Origin | Imported |
| Model | CPP700-H, CPP1000-H |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DataNet |
| Price | Upon Request |
| ADC Resolution | 16-bit |
| Input Channels | 4 analog/digital inputs per node |
| Wireless Protocol | Zigbee (IEEE 802.15.4) @ 2.4 GHz |
| Max RF Range (LoS) | 80 m (extendable to 800 m with repeaters) |
| Network Capacity | Up to 65,000 devices |
| Data Rate | 250 kbps |
| Security | 128-bit AES encryption |
| Memory | 59,000 samples per node |
| Sampling Interval | 1 s – 2 h (user-configurable) |
| Power | Rechargeable internal battery + external 12 VDC @ 2 A adapter |
| Operating Temperature | −20 °C to +50 °C |
| Certifications | CE, FCC |
| Compliance | RoHS, FCC Part 15, EN 300 328 |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DPSS-6100 |
| Product Type | Online Dew Point Analyzer Sampling System |
| Measurement Principle | Capacitive Polymer Sensor-Based Dew Point Detection |
| Pressure Rating | Up to 20 MPa (for integrated pressure regulator) |
| Filtration Precision | 2 µm (stainless steel sintered filter element) |
| Flow Control Range | 0–2 L/min (adjustable via precision needle valve) |
| Compliance Standards | GB 50029-2014 (Compressed Air Station Design Code), GB 50093-2013 (Code for Construction and Quality Acceptance of Automation Instrumentation Engineering), GB 50030-2013 (Oxygen Station Design Code) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Product Type | Import |
| Model | FGS |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | GPS-III |
| Price | Upon Request |
| Pressure Range | 200 / 276 / 500 MPa |
| Pressure Medium | Hydraulic Oil or Water |
| Control Stability | 0.005 % FS (0.05 % FS at 500 MPa) |
| Accuracy | 0.01 % FS (0.1 % FS at 500 MPa) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | MSP5100 |
| Output Signal | Custom Analog or Digital (Configurable) |
| Power Supply | 5 VDC |
| Accuracy | ±0.25% FS (Combined Nonlinearity, Hysteresis, Repeatability) |
| Long-Term Stability | ±0.25% FS/year |
| Operating Temperature Range | -40°C to +125°C |
| Compensated Temperature Range | -20°C to +85°C |
| Burst Pressure | 5× Rated Pressure |
| Overpressure Limit | 2× Rated Pressure |
| Pressure Cycles | >10 Million |
| Vibration Resistance | ±20 g (per MIL-STD-810C, Method 514.2) |
| Shock Resistance | 50 g (½-sine pulse, per MIL-STD-202F, Method 213B) |
| EMC Compliance | EN 55022 Class A/B |
| Housing Material | Monolithic 17-4PH or 316 Stainless Steel |
| Sealing | All-Metal, Weld-Free, O-Ring-Free Hermetic Construction |
| Media Compatibility | Compatible with media compatible with 316L stainless steel |
| Weight | 82.2 g |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | NS-10AAL2-UFG |
| Output Type | Analog Voltage (0.15 V/°) & Temperature-Compensated |
| Measurement Principle | Electrolytic Capacitive Sensing |
| Axis Configuration | Dual-Axis (X/Y) |
| Full-Scale Range | ±10° |
| Resolution | 0.001° (typ.), 0.01° (min.) |
| Absolute Accuracy | ±0.08° to ±0.3° (within 0–50°C, temp.-compensated) |
| Nonlinearity | ≤1.5% FS |
| Cross-Axis Sensitivity | ≤0.15% FS |
| Temp. Drift | ≤8 mV/°C |
| Output Voltage Range | 0.3–4.7 V |
| Supply Voltage | 5 VDC ±5% |
| Operating Temp. | −40°C to +85°C |
| Storage Temp. | −40°C to +85°C |
| Weight | 20 g |
| Dimensions (W × D × H) | 45 × 45 × 14 mm (max. 20 mm height with mounting features) |
| Integrated Temperature Sensor | Yes |
| Mounting | PCB-mount (surface-mount compatible) |
| Vibration Resistance | High (designed for industrial mobile platforms) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | PGC Instruments, Inc. |
| Type | Upright Environmental Test Chamber |
| Capacity | 25 cu ft (708 L) |
| Temperature Range | 8–45°C |
| Temperature Uniformity | ±0.2°C |
| Temperature Accuracy | ±0.2°C |
| Relative Humidity Range | 20–83% RH |
| RH Uniformity | ±0.5% RH |
| RH Accuracy | ±1.0% RH |
| RH Uncertainty | ±0.5% RH |
| Power Supply | 115 V / 16 A / 60 Hz or 220 V / 12 A / 50 Hz (single-phase) |
| Construction | Corrosion-resistant stainless steel (interior & exterior) |
| Controller | SmartPad™ with real-time display, programmable alarms, and RS-232 serial output |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PTS 420 |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TO2-1 |
| Measurement Principle | Electrochemical Micro-Fuel-Cell |
| Detection Range (Trace) | 0–10 ppm to 0–10,000 ppm O₂ |
| Detection Range (Percent-Level) | 0–25% O₂ |
| Response Time (T90) | 13 s |
| Accuracy | ±2% of reading |
| Repeatability | ±0.5% |
| Temperature Coefficient | 2.5 %/°C |
| Operating Temperature | 0–50 °C |
| Storage Temperature | 0–45 °C |
| Recommended Flow Rate | 0.5–2 SCFH (0.24–0.94 L/min) |
| Humidity Range | 0–100% RH (non-condensing) |
| Expected Service Life | 15–21 months |
| Shelf Life | 3 months |
| Warranty | 6 months |
| Output Signal | 330–585 µA |
| Electrical Interface | Center Foil (Negative), Outer Foil (Positive) |
| Compliance | Compatible with ASTM D3764, ISO 8573-3, USP <915>, FDA 21 CFR Part 11 (when integrated into validated systems) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | YK180-0803 Series |
| Range | 0–254.0 mm |
| Dimensions | 37.8 mm × 43.1 mm |
| Weight | 57 g |
| Brand | York Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YKDC220 |
| Application | Laboratory-grade dew point calibration system |
| Measurement Principle | Chilled-mirror hygrometry |
| Operating Temperature | 20–25 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.1 °C (dew point) |
| Dry Gas Generator | GS-1000 with PSA drying |
| Minimum Achievable Dew Point | ≤ −80 °C |
| Input Pressure | ≥ 0.8 MPa |
| Output Pressure Range | 0–0.3 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 485 × 500 × 260 mm |
| Weight | 20 kg |
| Interface | RS485 |