| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | 250i |
| Temperature Range & Accuracy | 3 °C to 55 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Control (at 37 °C) | >93% RH |
| Chamber Capacity | 255 L |
| O₂ Control Range | 1–21% (hypoxic) and 5–90% (hyperoxic) |
| Sterilization Cycle | 180 °C dry-heat, 6-log bioburden reduction |
| Air Filtration | ISO 5 certified HEPA, full-chamber air exchange every 60 s |
| Recovery Time (after door opening) | ≤10 min for all parameters |
| Humidity Recovery Rate | 5× faster than conventional water pan systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | 51026280 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% RH at 37°C |
| Chamber Volume | 150 L (5.3 cu. ft.) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model Numbers | 51030476, 51030286, 50145503, 50145517 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >93% RH at 37°C |
| Capacity | 165 L (5.8 cu. ft.) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 310 Series |
| Temperature Range | 5°C above ambient to 50°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| Relative Humidity (at 37°C) | Ambient RH to 95% |
| Humidification Pan Capacity | 3.0 L (standard) |
| Internal Volume | 184.1 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 663 × 978 × 627 mm |
| Input Pressure | 15 PSIG |
| CO₂ Sensor Type | Thermal Conductivity (T/C) or Infrared (IR) |
| Standard/Maximum Shelving | 4 / 17 shelves |
| Net Weight | 96 kg |
| Air Filtration | HEPA Filter, Class 100 Internal Environment |
| Control System | Enviro-Scan™ Microprocessor-Based Environmental Monitoring and Control System |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3110 Series |
| Chamber Volume | 184.1 L |
| Water Jacket Capacity | 43.5 L |
| Temperature Range | Ambient +5°C to 55°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| O₂ Range | 1–20% |
| O₂ Sensor Type | Fuel Cell |
| Relative Humidity (at 37°C) | Ambient to 95% RH |
| Humidification Pan Capacity | 3.0 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 668 × 1003 × 635 mm |
| Standard Shelving | 4 shelves (max 17) |
| Net Weight | 120 kg |
| HEPA Filtration | Class 100 internal environment |
| Power Input Pressure | 15 PSIG |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3951 |
| Temperature Range | Ambient +5°C to 60°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Temperature Uniformity (at 37°C) | ±0.3°C |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Options | Off / Medium (>80%) / High (>90%) |
| Internal Volume | 821.2 L |
| Internal Dimensions (W×H×D) | 787 × 1524 × 686 mm |
| External Dimensions (W×H×D) | 965 × 2032 × 838 mm |
| Shelf Capacity | 5 standard / up to 27 stainless steel shelves |
| Total Shelving Area | 13.5 m² |
| Humidity Reservoir Volume | 15.1 L |
| CO₂ Sensor Type | Thermal Conductivity (T/C) |
| Input Gas Pressure | 15 PSIG |
| Heated Inner Glass Door | Yes |
| Dual External Port Access (Left/Right) | Yes |
| Power Fail Memory for Setpoints & Calibration Values | Yes |
| Automatic CO₂ Cut-off on Outer Door Opening | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 3951 |
| Capacity | 821 L (29 cu. ft.) |
| Temperature Control Range & Accuracy | Not specified |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control Range & Accuracy | Not specified |
| CO₂ Sensing Technology | Thermal Conductivity (TC) Sensor |
| Door Configuration | Triple-pane tempered glass |
| Airflow System | Horizontal laminar airflow |
| Interior Material | Polished stainless steel |
| Shelving | Solid stainless steel, removable |
| Mobility | Locking casters with leveling feet |
| Port Access | Two wall-penetrating ports (left and right) |
| Control System | Enviro-Scan™ microprocessor-based controller with alphanumeric LED display |
| Humidity Management | Three rH modes (Off / Medium / High) |
| Safety Features | Dual independent temperature probes with over-temperature protection |
| Data Monitoring | Onboard sensor diagnostics and real-time status logging |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestically Produced Equipment |
| Model | Forma Steri-Cycle CO₂ Incubator (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Airflow Cycle Duration | ~14 hr |
| Sterilization Temperature | 140°C |
| Temperature Alarm Threshold | ≥60°C |
| HEPA Filtration Class | ISO Class 5 (Class 100) |
| Control System | Microprocessor-Based with Alphanumeric Display |
| CO₂ Sensor Options | Infrared (IR) or Thermal Conductivity (TC) |
| Humidity Monitoring | Optional |
| Door Configuration | Reversible Swing |
| Compliance Support | IQ/OQ Documentation Kits Available |
| Data Logging | Optional Integrated Datalogger |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Forma Steri-Cycle i160 |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 20–95% RH |
| Chamber Capacity | 165 L |
| CO₂ Sensor | IR-based (Si-MEMS), 0–20% range |
| Optional O₂ Control | 1–21% |
| Sterilization | Dry-heat cycle at 180 °C, 12-log SAL |
| Air Filtration | ISO Class 5 HEPA |
| Humidification System | Integrated covered reservoir (condensate-free) |
| Airflow Technology | THRIVE™ laminar airflow |
| Interior Material Options | Electropolished stainless steel or 100% copper |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | i250 |
| Temperature Range & Accuracy | 3 °C to 55 °C (±0.1 °C setpoint stability) |
| Temperature Uniformity | ±0.1 °C across chamber volume |
| Humidity Control | >93% RH at 37 °C |
| Chamber Capacity | 255 L |
| Sterilization Cycle | 140 °C dry-heat, 14-hour duration |
| Air Filtration | Internal HEPA filter (ISO Class 5 / Grade A equivalent), optional VOC adsorption module |
| Sensor Type | High-temperature-resistant TC sensor (in situ during sterilization), IR-based CO₂ sensing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Heracell VIOS 160i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 20–95% RH |
| Chamber Volume | 165 L |
| CO₂ Sensor | IR180Si infrared (MEMS-based) |
| Optional O₂ Control | 1–21% |
| Sterilization Cycle | Steri-Run dry heat at 180 °C (12-log SAL) |
| Air Filtration | Internal HEPA filter (ISO Class 5) |
| Chamber Liner Options | Electropolished stainless steel or 100% pure copper |
| Door Configuration | 6 airtight individual doors + 3 adjustable shelves |
| Humidification System | Integrated covered reservoir (condensation-free operation) |
| Control Interface | iCAN touchscreen with full audit trail and parameter logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 370 Series |
| Temperature Range | Ambient +5°C to 50°C |
| Temperature Uniformity (at 37°C) | ±0.3°C |
| Temperature Control Accuracy | ±0.1°C |
| CO₂ Control Accuracy | Better than ±0.1% |
| CO₂ Sensor Type | Thermocouple (T/C) or Infrared (IR) |
| Humidity Range (at 37°C) | Ambient RH to 95% RH |
| Humidification Reservoir Capacity | 3.0 L (standard) |
| Internal Volume | 184.1 L |
| Internal Dimensions (W×H×D) | 540 × 681 × 508 mm |
| External Dimensions (W×H×D) | 663 × 1003 × 635 mm |
| Standard Shelf Quantity | 4 |
| Net Weight | 118 kg |
| Sterilization Cycle Duration | ~14 h (including preheat, sterilization at ≥180°C, and cool-down) |
| Air Exchange Rate | One full internal air exchange per minute via Class 100 HEPA filtration |
| Key | Temperature Range: Ambient +4°C to 50°C |
|---|---|
| Temperature Uniformity | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Range | Up to 90% RH at 37°C |
| CO₂ Range | 0.3–19.9% |
| CO₂ Accuracy | ±0.15% |
| CO₂ Sensor Type | Infrared (IR) |
| Chamber Volume | 200 L |
| Internal Dimensions (W×D×H) | 630 × 510 × 665 mm |
| External Dimensions (W×D×H) | 790 × 730 × 960 mm |
| Net Weight | 112 kg |
| Shelf Capacity | 3 stainless steel shelves |
| Power Supply | 230 V, 50 Hz |
| Optional Accessory | HEPA filtration system |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 3423 / 3429 |
| Price Range | USD $14,000 – $70,000 |
| Chamber Material | Polished Stainless Steel |
| CO₂ Range | 0–20% |
| CO₂ Sensor Options | TC or IR |
| Humidity Control | Passive (Water Pan) |
| Temperature Range | Ambient +5°C to 50°C |
| Internal Volume | 184 L (6.5 cu ft) |
| Interior Dimensions (D×W×H) | 50.8 × 54.1 × 68.1 cm |
| Exterior Dimensions (L×W×H) | 63.5 × 100.3 × 66 cm |
| Net Weight | 166 kg |
| Electrical Requirement | 230 V, 50/60 Hz |
| Certifications | UL, CUL, CE |
| Data Output | Optional 4–20 mA analog signal |
| HEPA Filtration | Rapid 100-level air purification in <5 min |
| Alarm System | Audible/visual alerts for temperature deviation, CO₂ high/low, door open, low water, filter life, and cold ambient conditions |
| User Interface | Graphical “Message Center” with configurable access codes, calibration prompts, and maintenance scheduling |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Cytomat 10C |
| Temperature Range & Accuracy | +4 to 50 °C, ±0.1 °C setpoint stability |
| Temperature Uniformity | ±0.2 °C across chamber volume |
| Humidity Control | Up to 98% rH, Hydra-Smart active humidification with sterile water reservoir and particulate filtration |
| Capacity | 210 microplate positions (standard 96-/384-well format) |
| Decontamination | Fully automated ContraCon dry-heat decontamination cycle (180 °C, validated for low-bioburden heat-resistant microorganisms) |
| Optional Configuration | Copper-lined interior for enhanced antimicrobial surface performance |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3110 Water-Jacketed Series |
| Quotation | Upon Request |
| Temperature Range | Ambient +5°C to 55°C |
| Temp. Control Accuracy | ±0.1°C |
| Temp. Uniformity | ±0.2°C @ 37°C |
| CO₂/O₂ Control Accuracy | Better than ±0.1% |
| CO₂ Range | 0–20% |
| O₂ Range | 1–20% |
| Resolution (CO₂/O₂) | 0.1% |
| RH Range | Ambient to 95% @ 37°C |
| RH Display Increment | 1% |
| Water Jacket Volume | 43.5 L |
| Internal Volume | 184.1 L |
| Interior Material | Perforated 304 Stainless Steel |
| Sterilization Temperature | 140°C |
| Brand | Thermo Scientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model Variants | 371 GPCN / 381 GPCN |
| Quotation | Upon Request |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% |
| Chamber Capacity | 184 L |
| External Dimensions | 66.3 cm × 100.3 cm × 63.5 cm (W × H × D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestically Produced |
| Model | Forma Steri-Cycle CO₂ Incubator (China-Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Forma Steri-Cycle Series CO₂ Incubator |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model Numbers | 51026281 (Heracell 150i), 50116049 (Heracell 240i) |
| Price Range | USD 13,500 – 68,000 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HERAcell 150i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control | >99.5% RH (non-condensing) |
| Chamber Capacity | 150 L |
| Sterilization Method | ContraCon 90 °C moist-heat |
| CO₂ Sensing Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) |
| Optional O₂ Control Range | 1–21% or 5–90% |
| Interior Material | Electropolished stainless steel (optional 100% pure copper) |
| Door Configuration | Triple-pane tempered glass inner doors (3-door configuration for 150 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | 51026333, 51026334 |
| Temperature Range & Accuracy | 0–50 °C ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control Range & Accuracy | 5–95% RH ±2% RH (at 37 °C, 5% CO₂) |
| Chamber Capacity | 240 L |
| Sterilization Method | In-chamber 90 °C moist-heat (ContraCon) |
| Interior Material | Electropolished stainless steel or optional copper-lined chamber |
| Humidity System | Water-jacket-free, active humidity generation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BBD6220 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C @ 37 °C |
| CO₂ Control Accuracy | < ±0.1% |
| CO₂ Range | 0–20% (resolution: 0.1%) |
| O₂ Range | 1–20% (resolution: 0.1%) |
| Relative Humidity | Ambient to 95% RH @ 37 °C |
| Internal Volume Options | 150 L, 220 L, 240 L |
| Chamber Material | Electropolished Stainless Steel or Antimicrobial Copper Alloy |
| Sterilization Modes | 90 °C Wet-Heat Automatic Cycle or 180 °C Dry-Heat Cycle |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Models | HERAcell 150i, HERAcell 240i |
| Chamber Material Options | Stainless Steel or 100% Pure Copper |
| ContraCon Sterilization | 90°C moist-heat, 25-hour cycle (validated at 90°C/9 K·h⁻¹) |
| Temperature Range | Ambient +3°C to 55°C |
| Temp Uniformity | ±0.5 K spatially, ±0.1 K over time |
| CO₂ Control Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) sensor |
| Optional O₂ Control Ranges | 1–21% or 5–90% |
| Humidity System | Water-free, heated base with angled reservoir (5× faster recovery vs. conventional water pan) |
| Internal Door Configuration | 3-panel (150i) or 6-panel tempered glass |
| Shelving | Full-width (423×465 mm / 560×500 mm), max 10/12 shelves |
| Load Capacity | 10 kg/shelf (full), 5 kg/shelf (half) |
| Sterilization Efficacy | Validated against bacteria, fungi, USP <23> spores, and mycoplasma |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Heracell VIOS 160i / Steri-cycle i160 |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.2 °C |
| Humidity Range & Accuracy | 20–95 % RH |
| Chamber Capacity | 165 L |
| Sterilization Method | 180 °C Dry-Heat |
| Air Filtration | ISO Class 5 HEPA |
| CO₂ Control | IR-based, with iCAN intelligent logging system |
| Cell Compartmentalization | Cell Locker™ modular chamber system |
| Airflow Technology | THRIVE™ rapid-recovery laminar airflow |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | 50145502 / 51030287 / 51030478 / 50145515 |
| Price Range | USD $13,500 – $67,500 (based on configuration and regional pricing) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HERAcell VIOS 160i |
| Capacity | 165 L |
| Temperature Range & Accuracy | +3 °C above ambient to 55 °C |
| Temperature Uniformity | < ±0.3 °C |
| Humidity Control | >93% RH at 37 °C |
| CO₂ Sensing | MEMS-based IR180Si infrared sensor or TC180 thermal conductivity sensor |
| O₂ Control Range (optional) | 1–21% (hypoxic) or 5–90% (hyperoxic) |
| Sterilization | Automated 180 °C dry-heat Steri-Run™ cycle |
| Interior Material | 100% electrolytic copper or stainless steel |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heracell VIOS |
| Temperature Range & Accuracy | 3 °C above ambient to 55 °C, ±0.1 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Control | >93% RH at 37 °C |
| Chamber Capacity | 165 L |
| CO₂ Control Range & Accuracy | 1–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–21% or 5–90%, ±0.1% |
| Chamber Material | Electropolished stainless steel or 100% pure copper interior |
| Sterilization | 180 °C dry-heat, 12-h cycle |
| Data Interface | USB, remote alarm contacts, optional 4–20 mA output |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Thermo Scientific Heracell™ VIOS 160i CO₂ Incubator |
| Capacity | 165 L |
| Dimensions (W × D × H) | 34.6 × 25.1 × 35.4 in. (88 × 63.7 × 90 cm) |
| Humidity Control | Integrated covered water reservoir |
| Temperature Range | Ambient +3°C to 55°C |
| CO₂ Sensor Technology | Single-beam dual-wavelength infrared (IR) sensor or thermal conductivity (TC) sensor with RH compensation |
| O₂ Control Range | 1–21% (hypoxic) or 5–90% (hyperoxic) |
| Relative Humidity | >93% at 37°C |
| Air Filtration | ISO 5-class HEPA filter, full-chamber recirculation every 60 sec |
| Sterilization | 180°C Steri-Run dry-heat cycle |
| Power Requirement | 100 V, 50/60 Hz |
| Internal Chamber Material | Electropolished stainless steel (AISI 304, 18/8 grade) |
| Airflow System | THRIVE™ active airflow with internal fan |
| Door Design | Reversible outer door, adjustable perforated shelves |
| Safety | Dual independent temperature probes with overheat protection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Control Range & Accuracy | 1–20% (±0.1% typical deviation) |
| Capacity | 255 L (9.0 cu ft) |
| Chamber Material | Electropolished Stainless Steel or Copper-coated Stainless Steel |
| Humidity Control | Direct-heated, covered integrated water reservoir with rH compensation |
| Sterilization | Validated 180°C dry-heat cycle (12-log microbial reduction) |
| Air Filtration | ISO 5-class HEPA filter, full-chamber air exchange every 60 seconds |
| Recovery Time | All parameters restored within ≤10 min after door opening |
| Compliance | Designed to support GLP/GMP workflows |