Carbon Dioxide Incubator
Filter
Showing 61–90 of 157 results
| Brand | Herrytech |
|---|---|
| Origin | Shanghai, China |
| Model | YQ-80A-III |
| CO₂ Detection | Infrared (IR) |
| Temperature Control Range & Accuracy | Ambient +5°C to 65°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% |
| Humidity Control | >95% RH (at stable 37°C operation) |
| Chamber Capacity | 80 L |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| Standard Configuration | Imported infrared microcomputer CO₂-specific concentration probe |
| Brand | IRM |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ICA175 |
| Temperature Range & Accuracy | Ambient +5°C to 60°C ±0.1°C |
| Temperature Uniformity | ±0.1°C |
| Humidity Control | 95% ±3% RH |
| Chamber Capacity | 175 L |
| CO₂ Measurement | IR Sensor (Non-Drifting, Calibration-Free) |
| CO₂ Control Accuracy | ±0.1% at 5% setpoint |
| CO₂ Recovery Rate | ~1%/min after door opening |
| Humidification Reservoir | 3 L with cover |
| Filtration | HEPA Class H14 (≥99.999% @ 0.3 µm) |
| Sterilization | Integrated UV Lamp + HEPA Recirculation |
| Interior Material | Antibacterial Copper Alloy |
| Door Configuration | Standard Right-Swing (Left-Swing Optional) |
| Power Supply | AC 220 V, 500 W |
| Brand | IRM |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Water-Jacketed CO₂ Incubator |
| Model | ICW190 |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.1°C |
| Relative Humidity Control | 95% ±3% |
| Chamber Capacity | 190 L |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% (at 5% setpoint) |
| CO₂ Sensor Type | Infrared (IR-CO₂), drift-free, factory-calibrated |
| Humidification Reservoir | 3 L with cover |
| HEPA Filtration Efficiency | ≥99.999% for particles ≥0.3 µm |
| UV Sterilization Lamp | Standard |
| Internal Chamber Material | Antimicrobial Copper Alloy |
| Door Configuration | Right-hinged (left-hinge optional) |
| Power Supply | AC 220 V, 500 W |
| Brand | JTONE |
|---|---|
| Origin | Anhui, China |
| Model | HH.CP-TW |
| Capacity | 160 L |
| Temperature Range | RT+5°C to 50°C |
| Temperature Uniformity | ±0.3°C |
| Refrigerant | Eco-friendly non-CFC |
| Construction | Cold-rolled steel exterior with electrostatic powder coating |
| Airflow System | Vertical laminar airflow with forced convection circulation |
| CO₂ Control | Dual-stage infrared (IR) sensor-based regulation (5% setpoint typical) |
| Humidity Control | Passive water-jacket-assisted humidification (95% RH typical at 37°C) |
| Safety Features | Independent over-temperature cutoff, UV sterilization lamp, door-temperature compensation, microbial inlet filter (0.2 µm), optional CO₂ pressure regulator |
| Compliance | Designed to support GLP-compliant cell culture workflows |
| Software Interface | LCD microprocessor controller with real-time display of temperature, CO₂ concentration, and elapsed time |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTSQ-50A |
| Capacity | 50 L |
| Temperature Control Range | RT+5°C to 60°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | 35% ±5% RH (natural evaporation) |
| CO₂ Control Range | 0–20.0% (IR sensor, ±0.2% accuracy) |
| O₂ Control Range | 1.0–19.0% (hypoxic) or 23.0–50.0% (hyperoxic), up to 90.0% optional |
| O₂ Sensor | Imported zirconia |
| CO₂ Sensor | Imported NDIR infrared |
| Temperature Sensor | PT100 |
| Control System | PLC-based with 4.3″ capacitive touchscreen |
| Sterilization | UV lamp (optional 90°C moist-heat or 180°C dry-heat) |
| Heating Method | Air-jacketed |
| Internal Dimensions (W×D×H) | 340 × 340 × 450 mm |
| Standard Shelving | 2 stainless steel shelves |
| Power Consumption | 250 VA (±10%) |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Imported |
| Model Variants | ICO50 / ICO105 / ICO150 / ICO240 |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | 18–50 °C (±0.1 °C typical at 37 °C) |
| Temperature Uniformity | ±0.2–0.3 °C (at 37 °C, measured per DIN 12880) |
| CO₂ Concentration Control Range & Accuracy | 0–20% (±0.1% at 5% CO₂) |
| Humidity Control Range & Accuracy | 40–97% RH (±1.5% RH, non-condensing) |
| Chamber Volume | 56 L (ICO50 variant) |
| Dimensions (W×D×H) | 600 × 620 × 840 mm |
| Standard Configuration | Multi-point calibration support, Six-sided heating, IR CO₂ sensor, 180 °C dry-heat sterilization cycle (60 min), Dual Pt100 temperature sensors, Heated glass door, AtmoCONTROL software integration, USB + Ethernet connectivity, Internal SD card (10-year data logging capacity) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INC108 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INC153 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INC246 |
| Pricing | Upon Request |
| Brand | Microblox |
|---|---|
| Model | ECO-M |
| Category | CO₂ Incubator for Microfluidic Platforms |
| Origin | Beijing, China |
| Temperature Range | Ambient to 50 °C (customizable up to 65 °C) |
| Humidity Range | 5–95% RH |
| Internal Dimensions | 152 × 110 × 32 mm (L × W × H) |
| Chip Compatibility | Standard microscope slides (75 × 25 × 2 mm), dual 45 × 15 × 2 mm formats, PDMS/glass/plastic chips |
| Heating Method | Transparent metal-oxide conductive glass (uniform thermal distribution) |
| Observation Windows | Bottom optical glass (0.7–1.0 mm thick, customizable), top quartz or heated glass |
| Fluidic Interface | 1/16″ stainless steel ferrule ports |
| Gas Interface | Push-to-connect fittings (CO₂/O₂/N₂ mixing capable) |
| Electrical Interface | Quick-lock IEC 60320 C14 input |
| Sensor Accuracy | ±0.1 °C (PT1000 RTD) |
| Optional CO₂ Control | 0–15% v/v, flow rate 0.6–1.0 L/min |
| Brand | NUAIRE |
|---|---|
| Origin | USA |
| Model | NU-5800 Series |
| Temperature Range & Accuracy | Ambient to 55°C |
| Temperature Uniformity | ±0.35°C |
| Humidity Range & Accuracy | 5–90% RH |
| Capacity | 235 L (not lbs — corrected per industry standard |
| Chamber Construction | Seamless 304 stainless steel interior |
| Humidity Recovery | ≤15 min (from door opening) |
| CO₂ Control | IR sensor, 0–20% range, ±0.1% accuracy |
| Sterilization Options | Integrated dry-heat (180°C) and steam-humidity (≥90°C, 95% RH) cycles |
| Filtration | Dual-stage HEPA (99.99% @ 0.3 µm) recirculating air system |
| Compliance | FDA-listed device, ISO 13485-manufactured, CE-marked, compliant with ISO 5, USP <797>, and GLP/GMP environmental monitoring requirements |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MCO-18AIC, MCO-20AIC |
| Temperature Range & Accuracy | +5 °C to 50 °C (ambient 5–35 °C) |
| Temperature Uniformity | ±0.25 °C (at 25 °C ambient, 37 °C setpoint, 5% CO₂, no load) |
| Humidity Control | Natural evaporation via stainless steel humidification tray |
| Internal Volume | 170 L / 215 L |
| Heating System | Direct Heat Air-jacket (DHA) with three independent PID-controlled heating units |
| CO₂ Sensing | Ceramic infrared (IR) sensor, ozone-free UV sterilization (4 W, 253.7 nm), Cu-alloy antibacterial inner chamber |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MCO-5AC, MCO-18AC |
| Temperature Control Range & Accuracy | +5°C to 50°C (ambient: 5°C–35°C) |
| Temperature Uniformity | ±0.25°C (at 25°C ambient, 37°C setpoint, 5% CO₂, 5% O₂, no load) |
| Humidity Control Method | Natural evaporation via stainless steel humidification pan |
| Internal Volume | 49 L (MCO-5AC), 170 L (MCO-18AC) |
| CO₂ Control | On/off control with TC sensor |
| CO₂ Range | 0–20% |
| CO₂ Stability | ±0.15% (at 25°C ambient, 37°C setpoint, 5% CO₂, no load) |
| Humidity Level | 95 ± 5% RH (at 20°C ambient, 60% RH) |
| UV Lamp | Optional 4 W ozone-free ultraviolet lamp |
| Filtration | 0.3 µm CO₂ inlet filter (99.97% efficiency) |
| Alarm Functions | High/low temperature, CO₂ deviation, door open, low water level (MCO-5AC), independent overheat protection |
| Brand | Panasonic (Sanyo) |
|---|---|
| Origin | Japan |
| Model | MCO-5M, MCO-18M |
| Temperature Range & Accuracy | +5°C to 50°C (ambient: 5–35°C) |
| Temperature Uniformity | ±0.25°C (at 25°C ambient, 37°C setpoint, 5% CO₂, 5% O₂, no load) |
| Temperature Stability | ±0.1°C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | ±0.15% |
| O₂ Control Range | 1–18%, 22–80% |
| O₂ Control Accuracy | ±0.2% |
| Humidity Method | Natural evaporation via stainless steel humidification pan |
| Relative Humidity | 95 ± 5% RH |
| Internal Volume | 49 L (MCO-5M), 170 L (MCO-18M) |
| External Dimensions (W×D×H) | 480 × 548 × 575 mm (MCO-5M), 620 × 710 × 900 mm (MCO-18M) |
| Net Weight | 50 kg (MCO-5M), 97 kg (MCO-18M) |
| Power Consumption | 205 W (MCO-5M), 330 W (MCO-18M) |
| Heating System | DHA (Direct Heating Air-jacket) with triple independent heating units (MCO-18M only) |
| Sensor Types | Thermal Conductivity (CO₂, MCO-5M), IR (CO₂, MCO-18M), Long-life electrochemical (O₂) |
| Interior Material | Antimicrobial copper-alloy stainless steel |
| UV Lamp | 4 W ozone-free (optional) |
| Filtration | 0.3 µm HEPA-grade gas filter (99.97% efficiency for CO₂/O₂ or CO₂/N₂ lines) |
| Alarm Functions | High/low temperature, CO₂/O₂ deviation, door open, UV lamp fault, independent overheat protection |
| Brand | PHCbi |
|---|---|
| Origin | Japan |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Dual-channel Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT +5°C to 50°C, ±0.1°C |
| Temperature Uniformity | ±0.25°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.15% vol |
| Humidity Control | 95% RH (±5% RH, natural evaporation via humidification pan) |
| Chamber Capacity | 170 L |
| External Dimensions (W×D×H) | 620 × 730 × 905 mm (MCO-170AICL / MCO-170AICUVHL) or 620 × 755 × 905 mm (MCO-170AICUVL) |
| Key Configurations | SafeCell UV Sterilization System, H₂O₂ Decontamination Module with Generator & Reagent, Password-protected Electronic Outer Door Lock, Independent Inner Door Kit, CO₂ Pressure Regulator, Automatic CO₂ Cylinder Switching System, Standard Gas Auto-Calibration Kit, Copper-Alloy Stainless Steel Shelving & Half-Width Dividers, Stackable Mounting Brackets, Castor Base |
| Brand | PHCbi |
|---|---|
| Origin | Japan |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual Infrared (IR) Sensors |
| Temperature Control Range & Accuracy | RT+5°C to 50°C, ±0.1°C |
| Temperature Uniformity | ±0.25°C |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.15% |
| Humidity Control | 95% RH ±5% RH (Natural Evaporation via Humidification Pan) |
| Chamber Capacity | 230 L |
| External Dimensions (W×D×H) | 770 × 730 × 905 mm |
| Standard Configuration | SafeCell UV Sterilization System, H₂O₂ Decontamination Plate, Password-Protected Electronic Door Lock, Integrated H₂O₂ Generator & Reagent Kit, CO₂ Pressure Regulator, Automatic CO₂ Cylinder Switching System, Standard Gas Auto-Calibration Kit, Copper-Alloy Stainless Steel Shelving, Copper-Alloy Stainless Steel Half-Width Partition, Stackable Mounting Brackets, Castor-Mounted Base |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | ±0.1 °C at 37 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| CO₂ Concentration Control Range & Accuracy | 0–20% with ±0.1% accuracy at 5% setpoint |
| Internal Chamber Capacity | 3.8 L |
| Internal Dimensions (W×D×H) | 47.0 × 57.0 × 60.0 cm |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | ±0.1 °C at 37 °C |
| operating range | 5 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| CO₂ Concentration Control Range & Accuracy | 0–20% with ±0.1% accuracy at 5% setpoint |
| Humidity Control Range & Resolution | 1% RH |
| Chamber Capacity | 188 L |
| External Dimensions (W × D × H) | 69.5 × 67.0 × 97.0 cm (including display and leveling feet) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ID•Developer Kit |
| Price | USD 4,000 |
| Temperature Control Range & Accuracy | +5 °C to 50 °C |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Honeycomb Cell Culture System |
| Pricing | Upon Request |
| Temperature Control Range & Accuracy | RT+5°C to 50°C (±0.2°C) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0%–20% |
| Chamber Capacities | 30 L, 60 L, 100 L |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | C·BR-500S |
| Temperature Range & Accuracy | +20 to +40 °C, ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Capacity | 50 L (max. working volume: 25 L) |
| Rocking Angle | 3–12° |
| Rocking Speed | 3–40 rpm (angle × speed < 240) |
| Gas Control | O₂/CO₂ blending, concentration accuracy ≤ ±1% |
| Gas Flow Rate | 80–500 mL/min |
| Agitation Mode | Rocking (see-saw type) with adjustable tilt |
| Humidity Control | Not specified |
| Sensor Integration | Non-invasive DO and pH monitoring (optional, requires sensor-integrated 2D bioprocess bags) |
| Safety Features | Emergency stop, leakage circuit breaker, overtemperature protection, door interlock, pressure sensor |
| Construction | Stainless steel exterior |
| Dimensions (W×D×H) | 1500 × 720 × 1100 mm (excl. protrusions) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MG-1300-2A |
| Temperature Range | +5°C to +40°C above ambient |
| Temperature Uniformity | ±0.5°C (chamber), ±0.2°C (within vessel) |
| CO₂ Control Range | 3.0–8.0% (0.1% resolution), IR sensor |
| O₂ Monitoring Range | 1–25%, zirconia sensor |
| Gas Flow Rate | 2 L/min × 2 channels |
| Capacity | Two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacket + inline gas-line heating |
| Chamber Air Circulation | Horizontal-flow fan |
| Data Logging | Built-in Windows XP PC (6.5″ touchscreen), CSV/TXT export |
| Auto Gas Cylinder Switching | Standard |
| Safety | Liquid-expansion high-temp cutoff, control board alarm |
| Construction | Stainless steel interior and exterior |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 14,000 – 70,000 (FOB) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C, ±0.5°C uniformity in chamber, ±0.2°C in culture vessel (at +37°C, 5% CO₂, 25°C ambient) |
| Humidity Control | Not equipped |
| Capacity | Two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas stream heating |
| CO₂ Sensor | NDIR infrared (IR) type, control range 3.0–8.0%, resolution 0.1% |
| O₂ Sensor | Zirconia-based electrochemical sensor, display range 1–25% |
| Gas Flow | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Built-in Windows XP PC with 6.5" touchscreen, CSV/TXT export |
| Safety Features | Dual-stage overtemperature protection (electronic + liquid-expansion mechanical), controller fault alarm (audible), door-open interlock |
| Construction | Interior and exterior stainless steel (SUS304) |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excluding protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport cart), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 13,500–67,500 (est.) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C |
| Temperature Uniformity | ±0.5°C (chamber) |
| Humidity Control | Not equipped |
| Capacity | Dual-stack configuration supporting two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas-stream heating |
| CO₂ Sensing & Control | NDIR infrared sensor |
| O₂ Sensing | Zirconia-based electrochemical sensor |
| Gas Flow Rate | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Integrated Windows XP-based PC with 6.5" touchscreen |
| Safety Features | Control board alarm (audible), high-temperature liquid-expansion safety device |
| Construction | Stainless steel interior and exterior |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excl. protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport trolley), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MG-70C |
| Temperature Range | +5°C to +50°C |
| Temperature Uniformity | ±0.2°C |
| Temperature Control Accuracy | ±0.1°C (at 37°C, 5% CO₂) |
| Chamber Volume | 53 L |
| Heating Method | Air-jacketed (6-sided) |
| CO₂ Sensing | Infrared (IR) sensor |
| CO₂ Range | 0–20% (0.1% resolution) |
| Humidification | Passive water tray evaporation |
| Dimensions (W×D×H) | 460 × 541 × 638 mm |
| Internal Dimensions (W×D×H) | 320 × 410 × 400 mm |
| Weight | ~50 kg |
| Stackable | Yes (up to 2 units) |
| Standard Accessories | 3 shelves, 1 humidification tray, 2 × 5 m Pisco gas tubes (Ø6 mm) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 3404 Midi 40TM |
| Chamber Volume | 39.6 L |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity (at 37°C) | ±0.4°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| Relative Humidity (at 37°C) | Up to 95% |
| Internal Dimensions (W×H×D) | 30.5 × 35.5 × 35.5 cm |
| External Dimensions (W×H×D) | 47 × 46.5 × 59.7 cm |
| Shelf Quantity | 4 |
| Sensor Type | In-chamber TC sensor for CO₂ |
| Net Weight | 27 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 3111 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% RH at 37°C |
| Capacity | 6.5 cu. ft. (184 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | 3311 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Range & Control | Ambient to 95% RH, actively controlled |
| Chamber Capacity | 11.4 cu.ft. (322.8 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Forma™ Steri-Cycle™ i160 |
| Temperature Range & Accuracy | Ambient +3°C to 55°C |
| Temperature Uniformity | ±0.1°C |
| Humidity Control | >93% RH at 37°C |
| Chamber Capacity | 165 L |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | 250i |
| Temperature Range & Accuracy | 3 °C to 55 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Control (at 37 °C) | >93% RH |
| Chamber Capacity | 255 L |
| O₂ Control Range | 1–21% (hypoxic) and 5–90% (hyperoxic) |
| Sterilization Cycle | 180 °C dry-heat, 6-log bioburden reduction |
| Air Filtration | ISO 5 certified HEPA, full-chamber air exchange every 60 s |
| Recovery Time (after door opening) | ≤10 min for all parameters |
| Humidity Recovery Rate | 5× faster than conventional water pan systems |