Empowering Scientific Discovery

Changzhou Langbo Instrument Manufacturing Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo
OriginJiangsu, China
ModelZHWY-2112
Instrument TypeFull-Temperature Orbital Shaker
Timer Range1–999 h
Oscillation Frequency30–280 rpm
Amplitude30 mm (horizontal circular)
Temperature Range5–60 °C
Shelf Quantity2
Tray Dimensions800 × 500 mm
External Dimensions (per shelf)1280 × 770 × 1500 mm
Height Occupancy (stacked)1930 mm
Heating Power500 W (per shelf)
Cooling Power280 W (per shelf)
Refrigeration SystemImported compressor with R134a refrigerant
Control SystemMicroprocessor-based LED display with membrane keypad
Safety FeaturesOverheat protection, low-temperature cutoff, leakage current protection, door-open auto-stop, parameter encryption, and real-time alarm prompts for abnormal conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Instrument TypeWater Bath Constant-Temperature Shaker
ModelDKZ-3
Timing Range1–999 min
Oscillation Frequency40–150 rpm
Amplitude30 mm (orbital)
Temperature RangeRT + 5 °C to 100 °C
Temperature Uniformity±0.1 °C
Temperature Resolution0.1 °C
Chamber MaterialStainless Steel (304)
Chamber Dimensions (W×D×H)618 × 310 × 250 mm
Power Supply220 V, 50 Hz
Power Consumption1650 W
Number of Platforms1
DisplayDigital LED for temperature and speed
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo Instruments
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSP-8A
Instrument TypeHorizontal Oscillating Shaker
Timer Range1–999 min
Oscillation Speed0–200 rpm
Stroke Amplitude40 mm
Number of Platforms1
Maximum Bottle Capacity16 × 2000 mL
Power Consumption120 W
Voltage/Frequency220 V / 50 Hz
ComplianceHJ 557–2009 (China Environmental Protection Standard for Solid Waste Leaching Toxicity – Horizontal Oscillation Method)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo
OriginJiangsu, China
ModelLB-211B
Instrument TypeAir-Bath Constant-Temperature Orbital Shaker
Timer Range1–999 min
Oscillation Frequency50–250 rpm
Oscillation Amplitude30 mm
Temperature Range4–60 °C
Platform Quantity1
Capacity250 mL × 40 or 2000 mL × 6 (standard configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo
OriginJiangsu, China
ModelLB-2102
Timer Range0–999 h
Oscillation Frequency40–280 rpm
Orbit Diameter50 mm
Temperature Range4–60 °C
Temperature Resolution0.1 °C
Temperature Uniformity±1 °C
Temperature Stability±0.5 °C
Tray Dimensions750 × 500 mm
Number of Trays2
Max Capacity70 × 250 mL or 50 × 500 mL or 24 × 1000 mL
Drive TypeBrushless DC Motor
Control SystemMicroprocessor-based with Programmable Multi-Stage Profile (up to 10 segments)
Safety FeaturesIndependent Over-Temperature Cut-off, Door Interlock Switch, Motor Overheat Protection, Power-Fail Recovery, Soft-Start Acceleration
OptionalHumidity Control Module, USB Data Logging Interface, Stainless Steel Mirror-Finish Interior, Tempered Glass Viewing Window, Inert Gas Inlet Port
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginPRC
ModelSHA-C
PriceUSD 680 (FOB Jiangsu)
Temperature RangeAmbient +5°C to 100°C
Oscillation Frequency0–300 rpm
Stroke20 mm (Reciprocating)
Heating Power1800 W
Timer0–120 min or Continuous Operation
Capacity12 × 250 mL, 8 × 500 mL, or 4 × 1000 mL Erlenmeyer Flasks
Temperature Accuracy≤ ±1°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLangbo
OriginJiangsu, China
ModelTCLB-6A
Instrument TypeInverting Shaker
Temperature RangeAmbient +5°C to 60°C
Timer Range0–999 h
Speed Range0–45 rpm (no-load), 30 ±2 rpm (loaded, 2 L bottles)
Number of Shaking Plates2
Chamber MaterialStainless steel housing with electrostatic powder coating
internal fixturesaluminum alloy
Safety FeaturesOverload protection
Compatible Vessels2 L glass, PE, PTFE, and ZHE containers
ComplianceDesigned for GLP-compliant laboratory workflows requiring traceable, repeatable sample inversion under controlled thermal conditions
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0