Chemical Analysis Instruments
Filter
Showing 301–330 of 4194 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Agilent 7697A |
| Sample Vial Capacity (Standard) | 111 positions, including 3 priority vial slots |
| Sample Vial Capacity (Optional) | 12-position configuration for academic or low-throughput labs |
| Vial Sizes Supported | 10 mL, 20 mL, and 22 mL vials without adapters |
| Injection Valve Loop Volume | Not specified in source data |
| Carrier Gas Compatibility | Hydrogen (H₂), Helium (He), Nitrogen (N₂) |
| Leak Detection | Automated, real-time vial pressure integrity check prior to analysis |
| Pressure Control | Independent headspace vial pressure and column head pressure regulation |
| Barcoding | Integrated sample vial barcode reader with LIMS-compatible data transmission |
| Method Transfer | Cross-platform method conversion and rapid re-optimization via Agilent Method Translation Software |
| Multi-HeadSpace Modes | Multiple Headspace Extraction (MHE) up to 100 cycles per vial |
| Vial Depressurization | Automatic post-analysis vial depressurization before return to tray |
| Interface | GC inlet-compatible transfer line kit for co-location with Agilent 7693A ALS on same GC inlet |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Time | 999.99 min (maximum runtime) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| Power Requirement | 220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W) |
| Weight | 50 kg |
| Compliance | IEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose Analytical Chemistry |
| Detector Options | FID, TCD, FPD Plus, NPD, µECD |
| Injector Types | Split/Splitless, Packed Column, Purge-and-Trap, Headspace |
| Valve Configuration | Up to 3 Valves |
| Control Architecture | Full Electronic Pressure Control (EPC) from Injector to Detector |
| Software Interface | Compatible with OpenLab CDS and Third-party Data Systems |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A VL |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose analysis |
| Control System | Electronic Pressure Control (EPC) at inlet |
| Detector Regulation | Electronic Pressure Regulation (EPR) for FID |
| Included Configuration Options | SSL/EPC inlet + FID/EPR detector |
| Software | OpenLab CDS VL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.2–1 (adjustable) |
| Detection Limit (ng·L⁻¹) | ≤5×10⁻⁷ for low-mass elements, ≤1×10⁻⁷ for high-mass elements |
| Sensitivity (Mcps / mg·L⁻¹) | Li ≥ 80, Y ≥ 240, U ≥ 300 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 5–260 |
| Unit Mass Resolution (amu) | 0.5 |
| Detection Limit (ng·L⁻¹) | 10 |
| Sensitivity (Mcps / mg·L⁻¹) | 10 |
| Short-Term Stability (RSD %) | 3 |
| Long-Term Stability (RSD %) | 5 |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 400 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Cooling Mechanism | Low Thermal Mass (LTM) module enables rapid column heating and cooling |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | up to 970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | up to 970 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Heating/Cooling Rate | Enabled by Low Thermal Mass (LTM) modules for direct, rapid column heating and cooling |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data systems (when paired with OpenLab CDS or ChemStation software) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7900 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization with Quadrupole Mass Filtering |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Valve Temperature Control Range | Ambient + 5 °C to 300 °C |
| Sample Vial Capacity | 48 positions |
| Compatible Vial Sizes | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Pricing | Available upon request |
| Temperature Control Precision | Optional cooling plate enables sample stabilization at 4 °C |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 8860 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | +8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C to 50 °C in 5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8890 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 120 °C/min (75 °C/min with 120 V power supply) |
| Oven Cool-down | 4.0 min from 450 °C to 50 °C (ambient 22 °C) |
| Detector Options | FID, TCD, SCD, NCD, compatible with single-quadrupole, triple-quadrupole, and Q-TOF GC/MS platforms |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <0.5% RSD |
| Pressure Control Resolution | 0.001 psi |
| Dual-Tower Simultaneous Injection | Yes |
| Dimensions (W × D × H) | 58 cm × 51 cm × 49 cm |
| Microfluidic Flow Control Technology (CFT) | Fully integrated |
| Cryogenic Cooling Options | –80 °C (LN₂), –40 °C (CO₂) |
| Inlet Configurations | Up to 2 inlets + 10 valves |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 8900 |
| Instrument Type | Quadrupole-based Triple Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 990 GC |
| Detection Limit | 0.5 ppm (on WCOT capillary column) |
| Repeatability | RSD < 0.5% for 1 mol% propane on WCOT column under isothermal and isobaric conditions |
| Carrier Gases | Helium, Hydrogen, Nitrogen, Argon |
| Column Oven Max Temperature | 180 °C |
| Injector Max Temperature | 110 °C |
| TCD Linear Dynamic Range | 10⁵ (0.5 ppm to 5%) |
| TCD Concentration Range | 0.5 ppm to 100% |
| Inlet Pressure Rating | 100 kPa (14.5 psi) |
| Sample Loop | Micro-machined, fixed-volume, non-split |
| Detector Type | Micromachined Dual-Channel Thermal Conductivity Detector (TCD) |
| Maximum Independent Channels | 4 |
| Column Types Supported | WCOT, PLOT, Micro-packed (Hayesep D, Carboxen) |
| Peak Area Reproducibility | < 0.5% RSD |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AA DUO |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator Type | Custom High-Resolution Echelle Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Linear Dynamic Range | Sub-ppt to Percent-Level Concentrations |
| Automation | Fully Integrated Dual-Atomizer Control via Agilent Workstation Software |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ADS 2 |
| Pricing | Available upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 5000 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Photometric Range | ±8.0 Abs |
| Scan Speed | UV-Vis up to 2000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Purge | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 60 UV-Vis |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.5 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 6000i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–1800 nm (UV-Vis-NIR) |
| Automation Level | Motorized wavelength scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 8.0 Abs |
| Scan Speed | UV-Vis: 2000 nm/min |
| NIR | 8000 nm/min |
| Sample Compartment Z-height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Purge Capability | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Cary 630 |
| Instrument Type | Benchtop Fourier Transform Infrared Spectrometer |
| Wavenumber Range | KBr beam splitter: 7,000–350 cm⁻¹ |
| ZnSe beam splitter | 5,100–600 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Dimensions (W × D × H) | 14 × 26 × 16 cm |
| Weight | 3.5 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sample Compatibility | Solids, powders, pellets, liquids, gels, pastes, gases |
| Sampling Modules | Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath, Ge ATR, Mirror Reflection (10° and 45°), Transmission, Diffuse Reflectance, Gas Cell |
| Software | Agilent MicroLab, MicroLab Expert, MicroLab Pharma (optional, 21 CFR Part 11 & EU Annex 11 compliant) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 7000 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 10 Abs |
| Max Scan Speed | UV-Vis 2000 nm/min, NIR 8000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
