Chemical Analysis Instruments
Filter
Showing 3781–3810 of 4239 results
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin S13 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn, Au |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin S18 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| RSD | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | Kylin |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Optical System | Fully Orthogonal Dual-beam 3D Optical Path |
| Number of Channels | 2–4 Configurable |
| Reference Drift Correction | Enabled on All Channels |
| Hollow Cathode Lamps | Plug-and-Play Smart Lamps with Embedded Memory Chip |
| Lamp Current Monitoring & Usage Timer | Supported |
| Atomizer | Shielded Quartz Tube with Auto-height Adjustment & Temperature Control (100–400 °C) |
| Gas Flow Control | EFC (Electronic Flow Control) with PID Regulation, Real-time Pressure/Flow Monitoring & Safety Interlock |
| Vapor Generation | Chemical Vapor Generation with Multi-stage Gas-Liquid Separation |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn: < 0.01 µg/L |
| Hg, Cd | < 0.001 µg/L |
| Ge | < 0.05 µg/L |
| Zn | < 1.0 µg/L |
| Stability (Drift) | ≤1.5% |
| Noise | ≤1.5% |
| Inter-channel Interference | ≤±1.0% |
| Repeatability | ≤0.6% RSD |
| Linearity | >3 Orders of Magnitude |
| Power Supply | 220 V, 50 Hz, Max 400 W |
| Dimensions (H×W×D) | 52 cm × 76 cm × 68 cm |
| Net Weight | 40 kg |
| Communication Interfaces | LAN, USB, RS-232 |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L9 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Flow Rate Range | 0.01–10.000 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 10,500 PSI (72 MPa) at 0–2 mL/min |
| Flow Accuracy | ≤0.06% RSD |
| Autosampler Capacity | ≥108 positions (1.5 mL vials) |
| Injection Volume Range | 20–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5+ |
| Product Type | Flow Injection Analyzer |
| Portability | Integrated carry-on case with shock rating IK08, IP67-rated (submersible to 1 m for 30 min) |
| Detection Principle | Flow Injection Analysis (FIA) coupled with dual-beam spectrophotometry |
| Sample Introduction | Automated peristaltic pumping with intelligent flow path control |
| Pre-treatment Modules | On-board distillation, digestion, and liquid–liquid extraction |
| Detection Limits | Sub-ppb (ng/L) for target analytes including cyanide, phenols, ammonium, nitrate/nitrite, phosphate, Cr(VI), sulfide, and anionic surfactants |
| Software | Embedded method library, real-time system status monitoring, self-diagnostic interface, GLP-compliant audit trail |
| Connectivity | LAN and Wi-Fi enabled for multi-channel synchronization and remote operation |
| Compliance | Designed to support ASTM D3869, ISO 6776, ISO 15681-2, USP <621>, and EPA Method 354.1 workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Hyphenated LC-AFS System for Elemental Speciation |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Speciated Elements | As(III), As(V), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| RSD | <5% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As(III) ≤0.04 µg/L, DMA ≤0.08 µg/L, MMA ≤0.08 µg/L, As(V) ≤0.2 µg/L, SeCys ≤0.3 µg/L, SeMeCys ≤1 µg/L, Se(IV) ≤0.3 µg/L, SeMet ≤2 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | SA-50 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Atomic Fluorescence Spectrometry System |
| Application Scope | Elemental Speciation Analysis |
| Configuration | Modular, Integrated LC Pump(s), Dual-Column Oven, Column Switching Valve, UV Photochemical Reactor with Auto-Activation, Four-Channel Peristaltic Pump, LED Status Indicators, Optional Autosampler (96-/120-position) |
| Software | Unified Control Platform for Total Element and Speciation Quantification, Method Management, Hybrid Sequence Scheduling, Real-Time Instrument Monitoring, System Self-Diagnosis, Customizable Reporting Templates |
| Compliance Framework | Designed to support GLP/GMP-aligned workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Titan Instruments |
| Model | SAP-50 |
| Instrument Type | LC–AFS Hyphenated System for Elemental Speciation |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride/Vapor Generation Mode | On-line Hydride Generation (HG) and Cold Vapor Generation (CVG) |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Species | As(V), As(III), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| RSD | <4% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As(III) ≤0.04 µg/L, DMA ≤0.08 µg/L, MMA ≤0.08 µg/L, As(V) ≤0.2 µg/L, SeCys ≤0.3 µg/L, SeMeCys ≤1 µg/L, Se(IV) ≤0.3 µg/L, SeMet ≤2 µg/L |
| PMT Wavelength Range | Not specified |
| Atomizer Temperature Control Range | Not specified |
| Brand | Titan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Holographic Digital Grating + TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm (SupNIR-2700), up to 2500 nm (SupNIR-2720/2750) |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.05 nm |
| Absorbance Noise | <50 µA |
| Stray Light | <0.1% |
| Analysis Time | <60 s |
| Max. Simultaneous Parameters | 30 |
| Sample Mass | <120 g |
| Light Source Lifetime | >5000 h |
| Communication Interface | USB 2.0 |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 5–85 % RH |
| Power Supply | 198–242 V AC, 50 Hz, 0.5 A |
| Dimensions (L×W×H) | 400 × 420 × 360 mm |
| Weight | 18 kg |
| Chemometrics Software | RIMP (PLS, ANN, SIMCA, Hierarchical Clustering) |
| Model Transfer Capability | Cross-instrument compatible |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-1000A |
| Column Capacity | 1000 mL |
| Sample Injection Volume | 80 mL |
| Dimensions (W×D×H) | 628 × 918 × 1048 mm |
| Rotation Speed Range | 0–600 rpm |
| Separation Speed | 400–550 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–90 mL/min |
| Separation Flow Rate | 5.0–10 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detector Wavelengths | 254 nm, 280 nm |
| Temperature Control Module (external water bath interface) | 15–40 °C, ±0.5 °C accuracy, coolant flow rate 1–20 L/min |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-20A |
| Separation Capacity | µg–mg scale |
| Column Capacity | 20 mL |
| Injection Volume | 20 µL (standard), optional loops: 5 µL–2 mL |
| Injector Valve | Rheodyne 7725i |
| Rotation Speed Range | 0–2000 rpm |
| Operational Separation Speed | 1400–2000 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–5.0 mL/min |
| Recommended Separation Flow Rate | 0.5–1.5 mL/min |
| System Pressure Rating | 0–2 MPa |
| UV Detector Wavelengths | 254 nm & 280 nm (optional full-spectrum detector) |
| Temperature Control Range | 15–40 °C (via external recirculating chiller), accuracy ±0.5 °C, coolant flow rate 1–10 L/min |
| Power Supply | 220 V ±10%, 50/60 Hz, 300 W |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-30A |
| Column Capacity | 30 mL |
| Injection Loop Volume | 1 mL |
| Rotational Speed Range | 0–1400 rpm (infinitely variable frequency control) |
| Recommended Operating Speed | 1300 rpm |
| Flow Rate Range | 0.1–10.0 mL/min |
| Separation Flow Rate | 0.5–5.0 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detection Wavelengths | 214, 254, 280, 340, 365, 405 nm (optional full-spectrum detector available) |
| Temperature Control Range (via external circulator) | 15–40 °C (±0.5 °C accuracy) |
| Circulating Fluid Flow Rate | 1–10 L/min |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Power Supply | 220 V ±20 V, 50 ±0.5 Hz |
| Power Consumption | 200 W |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DS-100 Compact |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Mount | Rotatable Grating Stage |
| Spectral Resolution | ≤0.12 nm |
| Groove Density | 1200 grooves/mm |
| Wavelength Range | 200–800 nm |
| F-number | F/5 |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.3% T |
| Slit Widths | Fixed at 0.15 mm and 0.3 mm |
| Wavelength Repeatability | ±0.5 nm |
| Dimensions | 120 × 90 × 65 mm |
| Weight | 0.8 kg |
| Brand | Topo |
|---|---|
| Model | DS-100 |
| Wavelength Range | 200–800 nm |
| Focal Length | 300 mm or 500 mm |
| Relative Aperture | D/F = 1/7 |
| Wavelength Accuracy | ±0.4 nm |
| Wavelength Repeatability | ±0.2 nm |
| Scanning Method | Manual Drive with Digital Wavelength Display |
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range | Typically 200–900 nm (Xenon Lamp Source) |
| Excitation/Emission Monochromators | Czerny-Turner with Holographic Grating |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | ≤1 nm (FWHM at 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Sensitivity | >300 P-P, >1200 RMS, >15,000 RMS (Background-Subtracted) |
| Light Source | 150 W Pulsed or Continuous Xenon Arc Lamp |
| Detector | R928P Photomultiplier Tube (PMT) |
| Data Acquisition Modes | Emission Scan, Excitation Scan, Synchronous Scan, Time-Based Intensity Monitoring, 3D Excitation-Emission Matrix (EEM) |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop FTIR |
| Spectral Range | 7800–375 cm⁻¹ |
| Resolution | ≤1 cm⁻¹ (0.5 cm⁻¹ optional) |
| Scan Speed | Microprocessor-Controlled, 6 Adjustable Speeds |
| Signal-to-Noise Ratio | 30,000:1 (RMS, 2100 cm⁻¹, 4 cm⁻¹ resolution, DLATGS detector, 1-min acquisition) |
| Beam Diameter | 30 mm |
| Sample Aperture | 5 mm Ø |
| Interferometer | Self-Compensating Michelson with Active Alignment |
| Detector | Imported Low-Noise DLATGS |
| Source | Imported Long-Life Air-Cooled Ceramic IR Source |
| Beamsplitter | Multi-Layer KBr |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Linearity | ≤0.1% T |
| Data Interface | USB 2.0 |
| Dimensions (W×D×H) | 555 × 445 × 118 mm |
| Weight | 22 kg |
| Power | AC 90–230 V, 40 W |
| Operating Environment | 15–28 °C, <65% RH |
| Software Platform | Windows 98/2000/XP/Vista (32-bit) |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–375 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Scan Speed | Microprocessor-Controlled, 6 Adjustable Speed Settings |
| Signal-to-Noise Ratio (S/N) | 15,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Beam Splitter | 60 mm Ge-coated KBr with Hydrophobic Coating |
| Optics | Fully Gold-Coated Mirrors |
| Interferometer | Rocking-Mirror Interferometer (Space-Derived Design) |
| Environmental Protection | Integrated Heated Desiccant Chamber with Visual Indicator & Dual-Seal Enclosure |
| Purge Interface | Standard N₂ Purge Port |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP Audit Trail, Electronic Signatures, Role-Based Access Control |
| Brand | Topo |
|---|---|
| Model | FTIR920N |
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory FTIR |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | Up to 1 scan per 2 seconds (microprocessor-controlled) |
| Signal-to-Noise Ratio | 30,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector not included) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Brand | Topo |
|---|---|
| Model | FTIR 931 |
| Type | Portable FTIR Spectrometer |
| Wavenumber Range | 7800–375 cm⁻¹ |
| Resolution | ≤1 cm⁻¹ (down to 0.5 cm⁻¹) |
| Signal-to-Noise Ratio (S/N) | ≥15,000:1 (at 4 cm⁻¹, 1 min scan) |
| Scan Speed | Microprocessor-controlled, 6 selectable speeds |
| Beam Diameter | 30 mm |
| Sample Beam Spot | 5 mm Ø |
| Beamsplitter | Multi-layer coated KBr |
| Detector | Imported low-noise DLATGS |
| Source | Imported long-life, high-intensity air-cooled ceramic IR source |
| Interferometer | Laser-controlled automatic alignment and frequency calibration (He–Ne reference laser) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Linearity | ≤0.1% T |
| Aperture Ratio | f/3.2 |
| Data Interface | USB 2.0 |
| Dimensions (W×D×H) | 490 × 390 × 200 mm |
| Weight | 18 kg |
| Power Supply | 90–230 V AC / 12 V DC, 40 W |
| Operating Temperature | 15–28 °C |
| Relative Humidity | <65% RH (non-condensing) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation environment |
| Software | Windows 32-bit compatible (Win 98/2000/XP/Vista), FDA 21 CFR Part 11–ready audit trail & user access control modules included |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LIBS1 |
| Instrument Type | Benchtop |
| Integration Level | Fully Integrated |
| Laser Pulse Energy | >500 µJ |
| Pricing | Available Upon Request |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LR-1 / LR-2 |
| Pricing | Upon Request |
| Spectral Repeatability | ≤0.2 nm |
| Wavelength Range (LR-1) | 300–650 nm |
| Wavelength Range (LR-2) | 300–800 nm |
| Wavelength Accuracy | ≤±0.4 nm |
| Stray Light | ≤0.3% T |
| Relative Aperture | f/5.5 |
| Grating Density | 1200 lines/mm |
| Slit Width Adjustment | 0–2 mm (continuous, motorized or manual) |
| Slit Position Resolution | 0.01 mm per division (max. 20 mm travel) |
| Spectral Bandwidth (FWHM @ 589 nm, 3 mm height × 0.2 mm width slit) | ≤0.2 nm |
| Detection Unit | Single-Photon Counting Module (SPCM) |
| Excitation Source (LR-1) | He–Ne Laser (632.8 nm, >40 mW, linearly polarized, external cavity) |
| Excitation Source (LR-2) | Tunable-Power Semiconductor Laser (532 nm, >40 mW) |
| Optional Accessories | Notch Filter, Sample Holders for Solids & Liquids, Polarizer/Analyzer Set, Calibration Standards (e.g., Silicon, Cyclohexane) |
| Brand | Topo |
|---|---|
| Model | LR-3 |
| Type | Grating-Based Raman Spectrometer |
| Spectral Range | 200–800 nm |
| Spectral Resolution | ≤0.4 nm |
| Wavelength Accuracy | ≤0.4 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Excitation Source | 532 nm Semiconductor Laser |
| Laser Power | ≥50 mW |
| Slit Mechanism | Motorized Auto-Adjustable (Precision: 0.01 mm) |
| Monochromator | f/5.5, 1200 lines/mm Grating |
| Detection | Photon-Counting PMT with Discriminator Circuitry |
| Sample Stages | 5-Axis Adjustable, Backscattering, Liquid Cuvette, Solid, Capillary, and Polarization-Compatible Mounts |
| Software Compatibility | Windows XP / 2000 / Vista |
| Origin | Tianjin, China |
| Manufacturer | Topo Instrument Co., Ltd. |
| Brand | Topo/TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TJ270-30A |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Dispersive |
| Configuration | Laboratory Benchtop |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 1.5 cm⁻¹ |
| Scan Speed | Five Adjustable Settings |
| Signal-to-Noise Ratio | 15,000:1 |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Grating Scanning |
| Wavelength Range | 800–2500 nm |
| Spectral Resolution Options | 0.1–2.0 nm (adjustable scan speed) |
| Scan Speed | Up to 1 scan/s (at 2.0 nm step) |
| Data Acquisition Interval | 1 Hz |
| Measurement Modes | Transmission & Reflectance |
| Detector | PbS (Lead Sulfide) |
| Light Source | Tungsten-Halogen Lamp |
| Grating Density | 300 lines/mm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ±1 nm |
| Stray Light | ≤1% T at 1690 nm |
| Spectral Bandwidth Settings | Wide / Normal / Narrow / Very Narrow |
| Scan Modes | Continuous, Repeat, Time-Based |
| X/Y Axis Scaling | Fully Adjustable |
| Dimensions (W×D×H) | 710 × 560 × 240 mm |
| Weight | 45 kg |
| Chemometrics Software | RIMP (Near-Infrared Modeling Platform) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP-760A |
| Price Range | USD 21,000–28,000 (FOB) |
| Spectral Range | 280–2500 nm |
| Spectral Bandwidth | UV/VIS: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 5.0 nm (selectable) |
| NIR | 0.4–16.0 nm (auto/manual) |
| Wavelength Accuracy | ±0.5 nm (UV/VIS) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS) |
| Photometric Accuracy | ±0.3% T |
| Baseline Flatness | ±0.008 A (280–2500 nm, after 30-min warm-up) |