Chemical Analysis Instruments
Filter
Showing 3871–3900 of 10740 results
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-CH7 Multi-Station |
| Measurement Principle | Coulometric Karl Fischer Titration (Polarographic Current Detection) |
| Sample Heating Temperature | Up to 230 °C |
| Typical Analysis Time | ≤10 min per sample |
| Detection Limit | < 0.1 µg H₂O |
| Resolution | 0.1 µg |
| Compliance Basis | ASTM E203, ISO 8533, USP <921>, GB/T 11133, GB/T 6283 |
| Software Features | GLP-compliant audit trail, user permission levels, electronic signature support (21 CFR Part 11 ready) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 1 ppm – 100% water content |
| Resolution | ±0.1 µA |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Control Precision | 0.1 mA |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Sample Positioning | 8-position automated rotary sample carousel |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg |
| Water Mass Range | 3 µg – 199 mg |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Increment | 1/2000 of Burette Volume |
| Repeatability | ≥99% |
| Linearity (R²) | 0.995 |
| Electrode Type | Electrolytic Electrode |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage | Internal Non-Volatile Memory |
| Compliance | SH/T 1770–2010 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Titrator |
| Measurement Resolution | 0.1 µg (H₂O mass) |
| Water Content Range | 3 µg – 199 mg (0.01 µg detection limit for water mass) |
| Accuracy | ≤0.3% |
| Minimum Dispense | 3 µg |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Component | Electrolytic Electrode |
| Titration Control Precision | 0.1 µg |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% w/w |
| Resolution | 0.1 mV |
| Accuracy | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability | ±0.3% RSD |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Capacity | 10 mL / 20 mL |
| Titration Precision | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automated Coulometric & Volumetric Dual-Mode (Configurable) |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Precision | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability (RSD) | ≤0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity Options | 10 mL & 20 mL |
| Titration Control Accuracy | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GB/T 6283 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm – 100% w/w |
| Measurement Accuracy | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-V1 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Titrator |
| Moisture Content Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Measurement Resolution | 1 ppm |
| Endpoint Detection Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Water Titration Calibration Curve | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Configuration | 20 mL Long-Life Automatic Burette |
| Burette Dispensing Accuracy | ±0.001 mL (with 20 mL high-precision burette) |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV (endpoint detection) |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Titrant Delivery Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Endpoint Detection Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity (r²) | ≥ 0.998 |
| Polarization Voltage Range | 0–120 mV |
| Burette | 20 mL long-life automatic burette |
| Titration Control Accuracy | 0.001 mL |
| Power Supply | 110–240 VAC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Acetic Acid-Optimized) |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Control | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity framework |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Dual-Mode Capable) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric Option Support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Titration Control Accuracy | ±0.5 µL (20 mL burette) |
| Display | 7-inch color touchscreen (English/Chinese UI) |
| Compliance | GLP-compliant audit trail, 3-tier user permission system, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Dedicated for Ibuprofen Capsules |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-level user access control, FDA 21 CFR Part 11 ready configuration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-V6 |
| Pricing | USD 6,800 (FOB Shanghai) |
| Titration Mode | Fully Automated Volumetric Titration |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Volumetric & Coulometric Capable via Optional Module) |
| Measurement Resolution | 0.1 ppm |
| Water Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ≤ 0.3% RSD |
| Linearity Correlation Coefficient | ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records (expandable via USB export) |
| Brand | HOGON |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% (0.001–100 wt% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Sample Stirring Platform | Integrated magnetic stirrer with speed control |
| Electrode Configuration | Dual-platinum indicator electrode |
| Cell Design | Hermetically sealed titration cell with desiccant guard |
| Drift Compensation | Automatic enabled |
| Endpoint Hold Time | 10 s |
| Titration Delay | 5 s |
| Maximum Sample Volume | 50 mL |
| Maximum Titration Time | 30 min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric & Coulometric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% (0.001–100 wt% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (R²) | 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 VAC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% (0.001–100% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Lactose-Specific |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Dual-Mode Capable) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data handling |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Povidone K30-Specific |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001% – 100% w/w) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant data handling, 21 CFR Part 11–ready audit trail, ISO/IEC 17025–aligned operation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Starch-Optimized Configuration) |
| Moisture Range | 10 ppm – 100% H₂O (0.001% – 100% w/w) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AKF-V6 (2020 Release) |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ±0.3% |
| Linearity of Water Titration | R² ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Series Karl Fischer Online Moisture Analyzer |
| Pricing | Upon Request |
| Titration Mode | Fully Automated |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 1 ppm to 100% w/w water content |
| Measurement Resolution | Potentiometric: ±0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | ±0.003 Abs (0–1 Abs) |
| Titration Accuracy | Volumetric dosing precision ≤1 µL (20 mL burette) |