Chemical Analysis Instruments
Filter
Showing 3721–3750 of 10737 results
| Brand | Hexi |
|---|---|
| Model | RH2010SF-1 |
| Measurement Range | 0–60% w/w |
| Resolution | 0.01% |
| Accuracy | ±1% of reading |
| Display | TFT-LED digital |
| Sample Feed | Automated conveyor system |
| Operating Frequency | Fixed-frequency microwave source (ISM band, 2.45 GHz typical) |
| Compliance | Designed for industrial QC environments per ISO 712 and ASTM D4017 guidelines |
| Brand | HEXIN Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Model | GCMS 1000 / GCMS 1100 / GCMS 1200 |
| GC Type | Conventional GC-MS |
| Mass Range | Up to 1050 u (GCMS 1000) |
| Detector | Electron Multiplier (EM) |
| Ion Source | High-Temperature Inert Ceramic Ionizer |
| Vacuum System | High-Capacity Turbo Molecular Pump |
| Inlet Configuration | Modular Split/Splitless Injector |
| Temperature Program | Programmable Oven with Rapid Cool-Down (GCMS 1200) |
| Software | Fully Localized Chinese GC-MS Workstation with Deconvolution Algorithm |
| Compliance | Designed for ASTM D5845, ISO 17993, USP <621>, and HJ 909–2017 Method Implementation |
| Brand | HEXIN INSTRUMENT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCMS 1500 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Pricing | Upon Request |
| Brand | HEXIN Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| GC Configuration | Comprehensive 2D Gas Chromatography (GC×GC) |
| Model | GGT 0620 |
| Mass Range | Available upon request |
| Resolution | Available upon request |
| Sensitivity | Available upon request |
| Scan Speed | Up to 500 spectra/sec |
| Mass Accuracy | Available upon request |
| Oven Ramp Rate | Available upon request |
| Detector | Microchannel Plate (MCP)-based TOF detector |
| Pressure Control Precision | Available upon request |
| Brand | HEXIN Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GGT-0620 / GC×GC-TOFMS / LC-TOFMS / ICP-MS |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | Available upon technical consultation |
| Resolution | Available upon technical consultation |
| Sensitivity | Available upon technical consultation |
| Scan Speed | Available upon technical consultation |
| Mass Accuracy | Available upon technical consultation |
| Oven Ramp Rate | Available upon technical consultation |
| Detector Type | TOF-based electron multiplier array |
| Pressure Control Precision | Available upon technical consultation |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ICP-MS 1600 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory, Mobile Lab, Online Monitoring |
| Mass Range (amu) | Available upon request |
| Unit Mass Resolution (amu) | Available upon request |
| Detection Limit (ng·L⁻¹) | Available upon request |
| Sensitivity (Mcps / mg·L⁻¹) | Available upon request |
| Short-Term Stability (RSD) | Available upon request |
| Long-Term Stability (RSD) | Available upon request |
| Brand | HEXIN INSTRUMENT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | VOC-1500W |
| Pricing | Contact for Quotation |
| Brand | HEXIN KANGYUAN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Domain | Medical Device Testing & Clinical Microbiology |
| Model | CMl-1600 / CMl-3800 |
| Laser Source | 2000 Hz Solid-State Laser |
| Ionization Method | Matrix-Assisted Laser Desorption/Ionization (MALDI) |
| Database Capacity | >68,000 Strain Spectra Across 3,500+ Microbial Species |
| Vacuum System | Integrated High-Speed Turbomolecular Pumping Architecture |
| Software | MALDI Biotyper–Compatible Control & Analysis Suite with Custom Library Builder |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GC-MS 2000 |
| Instrument Type | Portable |
| Weight | Not Specified by Manufacturer |
| Mass Range | Available Upon Request |
| Mass Resolution | Available Upon Request |
| Dynamic Range | Available Upon Request |
| Scan Rate (Max) | Available Upon Request |
| Sensitivity | Available Upon Request |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC-TQ 5200 |
| Instrument Type | Triple Quadrupole (Tandem Quadrupole) |
| Application Scope | General-Purpose |
| Mass Range | Available upon request |
| Sensitivity | Available upon request |
| Resolution | Available upon request |
| Mass Accuracy | Available upon request |
| Operating Pressure Range | Available upon request |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPAMS 05 Series |
| Pricing | Upon Request |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPIMS 2000 |
| Pricing | Upon Request |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HF-901A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-Down Rate | 350 °C → 50 °C in <5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Zones | 8 independent zones with over-temperature protection |
| Display | 7-inch industrial color LCD touchscreen |
| Language Support | English & Chinese |
| Programmed Temperature Ramping | Up to 16 steps (expandable) |
| Maximum Run Time | 999.99 min |
| Injection Modes | Split/splitless capillary, packed column, valve injection, auto liquid/gas sampling |
| Detector Capacity | Up to 4 detectors simultaneously |
| Supported Detectors | FID, TCD, ECD, FPD, NPD, PDHID, PED |
| FID Detection Limit | ≤3.0×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Linear Dynamic Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene/toluene) |
| TCD Linear Dynamic Range | ≥10⁵ |
| FPD Detection Limits | S ≤2×10⁻¹¹ g/s, P ≤1×10⁻¹² g/s (methyl parathion) |
| ECD Detection Limit | ≤1.0×10⁻¹⁴ g/mL (γ-HCH) |
| NPD Detection Limits | N ≤1.0×10⁻¹² g/s (azobenzene), P ≤1.0×10⁻¹² g/s (malathion) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | HG-01 |
| Pricing | Upon Request |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Model | HG-C, HG-B |
| Pump Type | Single-channel peristaltic pump |
| Sample Introduction Mode | Continuous-flow hydride generation (flame-compatible) |
| Compatible Instruments | Universal interface for domestic and international atomic absorption spectrometers (AAS) |
| Memory Function | Onboard parameter retention across power cycles |
| Startup | One-button automated initialization |
| Detection Sensitivity (Hg) | ≥0.055 A at 5 ng/mL standard |
| Detection Sensitivity (As) | ≥0.055 A at 2 ng/mL standard |
| Precision (RSD) | ≤2% at 6 ng/mL As standard |
| Linearity (r²) | >0.998 for As calibration curve |
| Compliance | Designed to meet ASTM D3559, ISO 11929 (uncertainty evaluation), and USP <233> hydride-generation method requirements |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | 3F 1000/2000 Series |
| Mass Range | 1–300 amu (standard), up to 2500 amu (optional) |
| Detection Speed | 500 points/s |
| Resolution | 0.1% valley, 1% valley |
| Dynamic Range | 10⁷ |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁴ mbar |
| Electron Energy Control | 0–150 eV (fully programmable) |
| Stability | < ±0.5% peak height drift over 24 h |
| Quadrupole Rod Diameters | 6 mm, 9 mm, or 12 mm (user-selectable) |
| Detector Options | SEM, PIC, dual Faraday/SEM, or Faraday/PIC |
| Interface | RS232, USB, Ethernet |
| Software | MASsoft Professional |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPR20 QICPlus |
| Quotation | Upon Request |
| Mass Range | 1–50 / 1–200 / 1–300 / 1–500 / 1–1000 amu |
| Quadrupole Type | Residual Gas Analyzer (RGA) or Triple-Filter (3F) Configuration |
| Capillary Inlet | Integrated quartz capillary (2 m length), stainless-steel sheathed, heated to 200 °C |
| Gas Flow Rate | 1–20 sccm (adjustable) |
| Inlet Pressure Range | 100 mbar–2 bar (standard) |
| Mounting Options | Benchtop or vehicle-mounted (optional) |
| Detection Limit | 0.1–1 ppm (RGA HAL series, standard) |
| Mass Resolution Step | 0.01 amu (minimum scan increment) |
| Multi-Channel Inlet Valve | Up to 80 channels (heated or unheated, optional) |
| Calibration Gas Panel | Four-component gas delivery and pre-mixing manifold |
| Sample/Calibration Switching | Dual-gas-path inlet with low-dead-volume valves, auto/manual toggle between zero gas, calibration gas, and process sample |
| Inlet Filter | 5 µm sintered metal, high transmission, low dead volume, field-serviceable |
| Quantification Software | Automated calibration using certified reference gases |
| output units | %, ppm, ppb |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | EPIC |
| Mass Range | 1–300 amu (standard), up to 2500 amu (optional) |
| Detection Limit | 5 × 10⁻¹⁵ mbar (standard), 1 × 10⁻¹⁶ mbar (optional) |
| Energy Range | ±100 eV (standard), ±1000 eV (optional) |
| Resolution | 0.1% valley, 1% valley |
| Dynamic Range | 10⁷ |
| Measurement Speed | 500 points/s |
| Signal Gating Resolution | 0.1 µs |
| Stability | < ±0.5% peak height drift over 24 h |
| Quadrupole Diameter Options | 6 mm, 9 mm, 12 mm |
| Ion Source Control | Adjustable extraction voltage for soft ionization and appearance potential spectroscopy |
| Detector Options | Pulse ion counting (7-decade dynamic range), Faraday cup (up to 5 × 10¹⁰ ions/s) |
| UHV Compatibility | Standard UHV housing |
| Software | MASsoft Professional Suite |
| Upgrade Path | Compatible with Hiden Plasma/SIMS platforms (EQP, EQS, PSM, Maxim) via energy filter integration (Bessel Box, 45° sector, or electrostatic energy analyser) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | EQP |
| Mass Range | up to 2500 amu |
| Energy Resolution | 0.05 eV step / 0.25 eV FWHM |
| Ion Detection | Pulse-counting detector with 7-decade dynamic range |
| Signal Gating Resolution | 1 µs |
| Optional Floating Voltage | up to 10 kV |
| Interface | RS232, RS485, or Ethernet LAN |
| Detector Options | Faraday cup (high-density plasmas), electron attachment source (for apparent potential spectroscopy) |
| Vacuum System | Triple-differentially pumped quadrupole with 45° electrostatic sector energy analyser |
| Shielding Options | Mu-metal and radio-metal shielding available |
| Safety | Integrated Penning gauge and interlock system for overpressure protection |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EQS |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Range | Up to 2500 u |
| Analyzer Type | 45° Electrostatic Sector |
| Energy Resolution | 0.05 eV step / 0.25 eV FWHM |
| Detection | High-Sensitivity Pulsed Ion Counting Detector (7-decade dynamic range) |
| Pumping | Three-Stage Differential Pumping System |
| Ion Optics | Grating-Controlled Depth Profiling Capability |
| Interface | UHV-Compatible “Bolt-On” Mounting for Existing Surface Science Chambers |
| Compatibility | Fully Integrated with Hiden SIMS Workstation and MASsoft Control Software |
| Safety | Penning Gauge Interlock for Overpressure Protection |
| Communication | RS232, RS485, or Ethernet LAN |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAL 201 RC |
| Mass Range | 200 / 300 amu |
| Scan Speed | 100 amu/s |
| Minimum Step Size | 0.01 amu |
| Sensitivity | 0.1–1 ppm |
| Long-Term Stability | < ±0.5% peak height over 24 h |
| Minimum Detectable Partial Pressure | 5 × 10⁻¹⁴ mbar |
| Maximum Operating Pressure | 1 × 10⁻⁴ mbar |
| Ion Source | Gold-Plated Dual-Iridium Oxide Filament |
| Detector | Dual Faraday/Channeltron Electron Multiplier |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAL/3F |
| Mass Range | 1–50 amu (high-resolution quadrupole) |
| Detection Sensitivity | ppm-level |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Ionization Modes | Electron Impact (EI), Threshold Ionization (e.g., D₂/He selective detection) |
| Software Control | MASsoft v6.x |
| Data Output | ASCII, DDE-compatible (Excel, SPC-IV, custom SCADA/HMI systems) |
| Compliance | CE-marked, RoHS-compliant, designed for vacuum system integration per ISO 27893 and ASTM E1940-20 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HALO 201 MBE |
| Mass Range | 1–300 amu |
| Scan Speed | 100 amu/s |
| Minimum Scan Step | 0.01 amu |
| Sensitivity | 0.1–1 ppm |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹³ mbar |
| Maximum Operating Pressure | 1 × 10⁻⁴ mbar |
| Detector | Dual Faraday/Channelplate Electron Multiplier |
| Ion Source Shield | Contamination-Resistant |
| Filament Wiring | Molybdenum-Copper Alloy |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-40 DEMS |
| Mass Range | 50–300 amu |
| Resolution | < 1 amu |
| Sensitivity | 0.1 ppm (standard quadrupole) or 5 ppb (triple-filtered quadrupole option) |
| Electrode Interface | User-coatable Pt/C working electrode + 4 additional electrode ports |
| Membrane | Replaceable nanoscale hydrophobic membrane |
| Ionization | Soft ionization capability |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-40 |
| Mass Range | 200 / 300 / 510 amu (selectable) |
| Detection Limit | 5 ppb |
| Stability | < ±0.5% peak height over 24 h |
| Ion Source | Liquid Nitrogen-cooled cold trap |
| Inlet Options | 4-channel or 8-channel multiplexed membrane probes |
| Vacuum Protection | Penning gauge + interlock system |
| Control Interface | RS232, RS485, Ethernet LAN |
| Software | MASsoft v6.x |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-80 |
| Mass Range | up to 2500 amu |
| Detection Limit | 5 ppb |
| Inlet Pressure Range | 1 mtorr to atmospheric pressure |
| Ion Source Temperature | Heated, electropolished stainless steel |
| Stability | < ±0.5% peak height over 24 h |
| Calibration | Viscous-flow QIC-corrected inlet with purge capability |
| Control Software | MASsoft |
| Compliance | Designed for UHV/HP vacuum interfaces, compatible with ASTM E1943 (standard guide for mass spectrometry in process analysis), supports GLP/GMP data integrity requirements via audit trail and user access control |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | HPR20 QIC TMS |
| Mass Range | 1–50 / 100 / 200 / 300 / 500 / 1000 amu |
| Sampling Pressure | 100 mbar–2 bar (standard) |
| Response Time | <150 ms |
| Dynamic Range | 7 decades (pulse-counting detector) |
| Detection Limit | 5 ppb |
| Quantification Range | ppm to 100% |
| Stability | ±0.5% peak height over 24 h |
| Scan Speed | 100 amu/s |
| Measurement Rate | 500 data points/sec |
| Capillary | 0.9 m heated quartz inert capillary (up to 200 °C) |
| Ionization | APSI-MS soft ionization |
| External Analog Outputs | 2 standard, up to 16 optional |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR20 |
| Mass Range | up to 510 amu |
| Detection Limit | down to 5 ppb |
| Response Time | < 500 ms |
| Sample Flow Rate | 1–20 cm³/min |
| Sampling Pressure Range | 10 mbar to 2 bar (optional high-pressure inlet up to 30 bar) |
| Capillary Temperature | up to 200 °C |
| Ion Source Pressure Control | Automatic via integrated mass flow controller |
| Cryogenic Trap | Liquid nitrogen-cooled cold finger for condensable species |
| Ionization | Soft electron ionization (EI) with adjustable electron energy |
| Long-Term Stability | ±0.5% peak height drift over 24 h |
| Communication Interfaces | RS232, RS485, Ethernet |
| Software | MASsoft Professional v6.x with GLP-compliant audit trail and calibration management |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR30 |
| Mass Range | Up to 1000 amu |
| Detection Limit | Down to 5 ppb |
| Operating Pressure Range | 1×10⁻⁴ mbar to 1 mbar |
| Ionization | Soft Electron Ionization (EI) with Tunable Energy |
| Sensitivity Optimization | Direct re-entrant sampling orifice + differential pumping stage |
| Stability | < ±0.5% peak height drift over 24 h |
| Control Software | MASsoft v6.x (Windows-based, LAN-capable) |
| Safety Interlocks | Pneumatic isolation valve with pressure- and power-failure actuation |
| Data Acquisition | Simultaneous real-time acquisition, spectral processing, and alarm triggering |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR40 |
| Mass Range | 1–200 amu (optional 300 amu) |
| Detection Limit | 0.1 ppm (or 5 ppb) |
| Minimum Scan Step | 0.01 amu |
| Detector | Faraday Cup / Electron Multiplier |
| Quantitative Output Units | ppm, ppb, % |
| Ionization Mode | Soft Ionization |
| Software | Windows-based acquisition, real-time display & spectral analysis |
| Safety Feature | Fast-acting isolation valve for membrane breach protection |
| Sample Interface | Gas-permeable membrane probe or recirculating water sampler |