Chemical Analysis Instruments
Filter
Showing 4471–4500 of 4537 results
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | Omni-λ Imaging Monochromator Series |
| Pricing | Available Upon Request |
| Focal Length Options | 180 mm, 320 mm, 500 mm, 750 mm |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Mount | Dual- or Triple-Grating Turret |
| Grating Sizes | 40×40 mm, 68×68 mm (or 68×84 mm) |
| Wavelength Range | UV–VIS–NIR (190–2500 nm), Optimized for IR (>1 µm) with Gold-Coated Optics |
| Stray Light Suppression | ≤1×10⁻⁵ |
| Control Interface | USB 2.0 (standard), RS-232 (optional) |
| Drive System | DSP-Based Motorized Control |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or Motorized Adjustable Slit |
| Detector Compatibility | PMT, CCD (26 µm pixel pitch), InGaAs, MCT |
| Entrance/Exit Port Configuration | Single or Dual Input/Output (software-selectable) |
| Typical Resolution (1200 g/mm grating) | 0.028–0.35 nm (CCD/PMT dependent) |
| Wavelength Accuracy | ±0.1–±0.2 nm |
| Wavelength Repeatability | ±0.01–±0.1 nm |
| Scan Step Size | 0.0025–0.01 nm |
| Focal Plane Dimensions | 30 mm (w) × 10–14 mm (h) |
| Optical Axis Height | 146.5 mm |
| Relative Aperture | f/4 to f/9.7 |
| Key | Brand: ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | Omni-λ Grating Modules |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | Omni-λ Series |
| Type | Triple-stage grating monochromator |
| Focal Length | 500 mm per stage |
| Configuration | Two-stage subtractive dispersion + one-stage additive dispersion |
| Spectral Range | 200–800 nm |
| Wavenumber Range (at 325 nm excitation) | 50–18,000 cm⁻¹ |
| Resolution | 3 cm⁻¹ |
| Repeatability | ±5 cm⁻¹ |
| Imaging Range (single acquisition) | 700 cm⁻¹ |
| Grating Mounts | Three gratings per stage (9 total) |
| Grating Options | 1800, 1200, 600, 3600, and 2400 grooves/mm |
| Blaze Wavelengths | 250 nm, 300 nm, 500 nm |
| Grating Size | 68 × 68 mm |
| Reflectivity (peak) | ~70% across UV–Vis |
| Input/Output | Stage 1 & 2 — side-entry dual-output |
| Detector Compatibility | CCD array detectors, PMT, and other single-channel photodetectors |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Beijing Zolix Instruments Co., Ltd.) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ180D |
| Application System | Universal |
| Spectral Resolution | 0.25 nm |
| Linear Dispersion | 3.7 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| F-number | F/3.9 |
| Stray Light Level | <1×10⁻⁹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | Omni-λ180D |
| Price Range | USD 1,400 – 7,000 |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.25 nm (at 1200 g/mm grating) |
| Dispersion | 3.7 nm/mm (linear dispersion, at 1200 g/mm grating) |
| Wavelength Range | 190–1100 nm (dependent on grating selection) |
| F-number | F/3.9 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light Level | <1×10⁻⁹ |
| Brand | ZOLIX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | Omni-λ2002i |
| Application Systems | Transmission/Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Stray Light Level | 5 × 10⁻⁵ |
| Focal Length | 200 mm |
| f-number | f/3.5 |
| Optical Design | Czerny–Turner with Toroidal Imaging Correction |
| Entrance/Exit | Side-mounted entrance, side-mounted CCD exit |
| Grating Size | 50 × 50 mm |
| Slit Width Range | 0.01–3 mm (manual, motorized optional) |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| 焦 Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Wavelength Accuracy | ±0.1 nm (@1200 g/mm, 435.83 nm) |
| Wavelength Repeatability | 0.05 nm (@1200 g/mm, 435.83 nm) |
| Minimum Scan Step | 0.005 nm (@2400 g/mm) |
| Spectral Resolution (PMT) | 0.08 nm (@2400 g/mm, 435.83 nm) |
| Spectral Resolution (15-µm-pixel CCD) | 0.106 nm (@2400 g/mm, 435.83 nm) |
| CCD Single-Capture Spectral Range | 42 nm (@2400 g/mm, 30-mm CCD) |
| Mechanical Scan Range | 0–19,200 nm (dependent on grating) |
| Stray Light Suppression Ratio | 5 × 10⁻⁵ |
| Power Requirement | 100 W peak @ 24 V DC |
| Standard Interface | USB 2.0 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Omni-λ200i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Number of Gratings | Triple-grating turret mount |
| Spectral Resolution (CCD, 26 µm pixel) | 0.28 nm |
| Linear Dispersion | 3.6 nm/mm |
| Wavelength Range | 400–1000 nm |
| F-number | f/3.5 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light Level | 1×10⁻⁵ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Laboratory-grade Infrared Spectral Analyzer |
| Model | Omni-λ300i |
| Wavenumber Range | 4000–25000 cm⁻¹ |
| Spectral Resolution | 0.08 nm (with 1200 g/mm grating) |
| Signal-to-Noise Ratio | 8000:1 |
| Stray Light Level | ≤1×10⁻⁵ |
| Focal Length | 320 mm |
| f-number | f/4.2 |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Size | 68×68 mm |
| Grating Tower | Triple-grating turret |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Width Adjustment | 0.01–3 mm (manual or motorized option) |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Wavelength Accuracy | ±0.15 nm |
| Wavelength Repeatability | ±0.08 nm |
| Minimum Scan Step | 0.005 nm |
| Dispersion | 2.3 nm/mm (at 435.8 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Omni-λ300i |
| Application System | Universal |
| Grating Capacity | Triple-Grating Turret |
| Focal Length | 320 mm |
| Optical Design | Czerny-Turner with Toroidal Imaging Correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Options | Side or Dual Input/Output Configurable |
| Slit | Manual (0.01–3 mm width, 2/4/14 mm height), Motorized Slit Optional |
| Detector Interface | Dual CCD Output Standard |
| Control Interface | USB 2.0 (RS-232 Optional) |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.04–1.28 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.069–3.05 nm |
| Linear Dispersion (@435.83 nm) | 0.91–40.43 nm/mm |
| Scan Range | 0–19,200 nm (grating-dependent) |
| Scan Step | 0.0025–0.08 nm |
| F/# | f/4.2 |
| Image Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Dimensions | 420 × 295 × 232 mm |
| Weight | 16 kg |
| Max Power Consumption | 100 W @ 24 V DC |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λ500i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| Focal Length | 500 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Level | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Configuration | Side entrance, dual出口 (CCD + slit), configurable multi-port options |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Weight | 22 kg |
| Power Consumption | ≤100 W @ 24 V DC |
| Communication Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | DSP-based motorized turret & port selection |
| Wavelength Accuracy | ±0.1 nm to ±3.2 nm (dependent on grating) |
| Wavelength Repeatability | 0.015–0.8 nm (grating-dependent) |
| Spectral Resolution (with point detector) | 0.03–0.8 nm |
| Spectral Resolution (with 15 µm-pixel CCD) | 0.045–1.97 nm |
| Linear Dispersion (@435.83 nm) | 0.6–26.05 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025–0.08 nm (grating-dependent) |
| CCD Single-Capture Spectral Range (@30 mm sensor) | 18–781.5 nm (grating-dependent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| F/# | F/9.7 |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Entrance/Exit Configuration | Side entrance |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.02–0.36 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.033–1.329 nm |
| Linear Dispersion (@435.83 nm) | 0.43–17.58 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025 nm |
| CCD Single-Capture Span (@30 mm sensor) | 12.9–527.4 nm |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | Embedded DSP-based motion and port logic |
| Coating Options | Standard Al+MgF₂ (UV-VIS), gold (IR >1 µm), enhanced UV (e.g., MgF₂ overcoat) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750S |
| Application System | Universal |
| Grating Capacity | Triple-grating turret |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal image correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Entrance/Exit Options | Dual entrance, dual exit |
| Standard Interface | USB 2.0 |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual), motorized slit optional |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Relative Aperture | f/9.7 |
| Minimum Scan Step | 0.0025 nm (with 2400 g/mm grating) |
| Wavelength Accuracy | ±0.1 nm (at 435.83 nm, 2400 g/mm) |
| Wavelength Repeatability | ±0.015 nm (at 435.83 nm, 2400 g/mm) |
| CCD Spectral Resolution (15 µm pixel) | 0.026 nm (2400 g/mm) |
| Single-shot CCD Spectral Coverage | 12.9 nm (30 mm CCD, 2400 g/mm, 435.83 nm center) |
| Infrared Optimization | Gold-coated optics for >1 µm operation |
| UV Optimization | Optional UV-enhanced coatings |
| Power Supply | 24 V DC, peak 100 W |
| Dimensions (L×W×H) | 800 × 338 × 230 mm |
| Weight | 40 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λXi |
| Application Systems | Transmission/Reflection Spectroscopy |
| Grating Configuration | Triple-Grating Turret |
| Spectral Resolution | 0.35 nm (@1200 g/mm) |
| Linear Dispersion | 3.68 nm/mm |
| Wavelength Range | 400–1000 nm |
| F-number | f/1 |
| Wavelength Accuracy | ±0.25 nm (@1200 g/mm) |
| Stray Light | ≤0.1% (1×10⁻³) |
| Brand | ZOLIX |
|---|---|
| Model | Omni-λxxxD Series |
| Type | Dual-stage grating monochromator |
| Focal Length Options | 300 mm, 500 mm, or 750 mm per stage |
| Configuration Modes | Additive dispersion (high-resolution) and subtractive dispersion (low-stray-light) |
| Grating | 1200 g/mm standard |
| Slit Width | 0.01–3 mm (manual), motorized slit optional |
| Slit Height | 2 / 4 / 10 / 14 mm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Relative Aperture | F/3.9 (300 mm), F/6.5 (500 mm), F/9.7 (750 mm) |
| Linear Dispersion (1200 g/mm) | 1.35 / 2.7 nm/mm (Omni-λ300D, additive/subtractive) |
| Resolution (1200 g/mm) | 0.05 / 0.1 nm (Omni-λ300D, additive/subtractive) |
| Interface | USB 2.0 standard, RS-232 optional |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OmniEvo |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo |
| Price Range | USD 28,000–42,500 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm |
| Spectral Resolution | ±0.05 nm |
| Sensitivity | >3000:1 (Water Raman S/N ≥1000:1) |
| Wavelength Accuracy | ±0.15 nm |
| Spectral Range | 200–2500 nm |
| Excitation Sources | 150 W / 500 W Xenon Arc Lamp with Monochromator (Bandwidth 0.1–30 nm) |
| Optional Lasers | 266, 325, 375, 405, 442, 532, 785, 1064 nm |
| Detector Options | Cooled CCD (2000×256, 200–1000 nm), Cooled InGaAs Array (512×1, 800–2200 nm), PMT (200–870 nm), Cooled Single-Element InGaAs (800–2500 nm) |
| Signal Processing | Photon Counting or Lock-in Amplification |
| Optional Modules | Quantum Yield Measurement, Electroluminescence (EL), Cryogenic Sample Stage (≤10 K) |
| Emission Spectrum Correction | Built-in Absolute Intensity Calibration Function |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniFluo Series |
| Price Range | USD 28,000 – 43,000 (FOB) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 0.1–5.0 mm |
| Spectral Resolution | 0.1 nm (FWHM @ 546.1 nm) |
| Sensitivity | 3000:1 (Signal-to-Noise Ratio, RMS, water Raman peak at 350 nm excitation, 5 nm bandwidth, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm (Emission), ±0.25 nm (Excitation) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo-FLIM Series |
| Dispersion Element | Grating |
| Instrument Type | Steady-State/Time-Resolved Fluorescence Spectrometer |
| Spatial Resolution | ≤1 µm @ 100× Objective @ 405 nm Picosecond Pulsed Laser |
| Spectral Range | 200–900 nm |
| Minimum Time Resolution | 16 ps |
| Fluorescence Lifetime Range | 500 ps – 1 µs |
| Instrument Response Function (IRF) | ≤2 ns |
| Excitation Sources | 375–670 nm Picosecond Pulsed Lasers (50 MHz Repetition Rate, Pulse Widths: 25–75 ps) |
| Microscope | Upright Research-Grade with Brightfield/Darkfield Illumination, 5-Position Objective Turret (10×/50×/100×), High-Definition CMOS Monitoring Camera |
| XY Stage | Motorized, 75 × 50 mm Travel, 50 nm Minimum Step, <1 µm Repeatability |
| Spectrograph | 320 mm Focal Length, Imaging-Corrected Monochromator, Triple 68 × 68 mm Gratings, Wavelength Accuracy: ±0.1 nm, Repeatability: ±0.01 nm, Slit Width: 0.01–3 mm Motorized |
| Detector Options | UV-Vis PMT (185–900 nm), Back-Illuminated Deep-Depletion CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C Cooling) |
| TCSPC Module | Time Bins Down to 16 ps, Dead Time <10 ns, Up to 65,535 Histogram Channels, Instantaneous Saturation Count Rate: 100 Mcps |
| Software | OmniFluo-FM FLIM Acquisition & Analysis Suite (Multi-Exponential Fitting ≤4 Components, IRF-Free Fitting Modes, Pseudocolor Mapping, 3D Visualization, Line/Cross-Section/Histogram/Contour Tools) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | OmniFluo960 |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | ≤ 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 (at 350 nm excitation, 370–450 nm scan, 5 nm slit, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Focal Length | 320 mm |
| Stray Light | ≤ 1×10⁻⁵ |
| Detector Options | CR131 (cooled red-sensitive PMT, 185–900 nm), R928, R13456, H10330C-75, R5509-73 |
| Standard Sample Chamber | SAC-FLS with cuvette, powder & solid sample holders |
| Automated Light Shield | Yes |
| Dark Count | ≤ 100 CPS (at –10°C) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Model | OmniFluo990 |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Lifetime Range | 500 ps – 10 s |
| Excitation Source | Gloria75X 75 W Xenon Arc Lamp |
| Emission Monochromator | Omni-λ3027i (f = 320 mm) |
| Stray Light | < 1×10⁻⁵ |
| Grating Options | 1200 g/mm BLZ@500 nm, 600 g/mm BLZ@750 nm, 300 g/mm BLZ@1250 nm |
| Detector | Cooled Red-Sensitive PMT CR131 (185–900 nm), Dark Count ≤ 100 CPS at –10 °C |
| Data Acquisition | DCS900PC TCSPC Module (Timing Resolution: 16 ps – 33.55 µs |
| Max Count Rate | 100 Mcps) |
| Software | ZolixScan v4.x (Steady-State Scanning, Time-Resolved Kinetics, TRES, QY Calculation, Spectral Correction, GLP-Compliant Audit Trail) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniPL Series |
| Price Range | USD 28,000 – 42,500 |
| Dispersive Elements | Holographic Grating & Bandpass Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 10–2000 µm |
| Spectral Resolution | < 0.2 nm (@ 1200 g/mm grating) |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Detection Range | 300–850 nm (expandable to 2500 nm) |
| Detector | Scientific-grade, thermoelectrically cooled back-illuminated CCD (300–1000 nm) |
| Optional Cryogenic Stage | Closed-cycle cryostat, 2 K minimum operating temperature |
| Software | Fully programmable acquisition protocol engine with spectral arithmetic, batch processing, and audit-trail logging |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-LF325 |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Range | 300–850 nm (extendable to 2500 nm) |
| Spectral Resolution | < 0.2 nm (@1200 g/mm grating) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detector | Scientific-Grade Cooled Back-Illuminated CCD (300–1000 nm) |
| Cryogenic Compatibility | Optional Closed-Cycle Cryostat (down to 2 K) |
| Software | Customizable Acquisition Protocol, Spectral Arithmetic, Batch Processing, and GLP-Compliant Data Archiving |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-MicroS |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Type | Integrated Micro-PL Spectrometer |
| Spectral Range | 200–1600 nm |
| Excitation Wavelengths (Optional) | 325, 405, 442, 473, 532, 633, 785 nm |
| Mapping Area | 50 mm × 50 mm (customizable) |
| Cryogenic Compatibility | Down to 10 K (with optional cryostat) |
| Software Features | Emission Spectrum Correction, Auto-Mapping, EL & Raman Expansion Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | OmniPL-MicroS-A (Vertical-Path Configuration) |
| Price Range | USD 14,000 – 28,000 |
| Dispersive Element | Filter-Based Spectral Selection |
| Spectral Bandpass (Slit) | 200–1600 nm |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >100:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OmniRS-New |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2500 nm |
| Spectral Resolution | 200–4000 cm⁻¹ (typical) |
| Spectral Bandwidth (FWHM) | ≤5 cm⁻¹ |
| Minimum Wavenumber Shift | 5 cm⁻¹ |
| Wavenumber Repeatability | < ±0.1 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PMEye-3000 |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | PMEye-3000 Series |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Laser Options | 266 nm, 405 nm, 442 nm, 532 nm, 785 nm (internal) |
| Mapping Speed | >20 points/sec |
| Spatial Resolution | 10 µm (objective mode), 50 µm (lens mode) |
| Spectral Resolution | 0.1 nm @ 1200 grooves/mm |
| Max Sample Size | 8-inch wafer |
| Spectrometer | 500 mm focal length, triple-grating DSP-scanning monochromator |
| Detector Options | Si photodiode (200–1100 nm), R1527 PMT (200–680 nm), CR131 PMT (200–900 nm), DSi300 Si detector (200–1100 nm), DInGaAs1700 RT InGaAs (800–1700 nm), DInGaAs1900 cooled InGaAs (800–1900 nm), DInGaAs2200 cooled InGaAs (800–2200 nm), DInGaAs2600 cooled InGaAs (800–2600 nm) |
| Wavelength Accuracy | ±0.2 nm (@ 300 nm, 1200 g/mm), ±0.6 nm (@ 500 nm, 600 g/mm), ±0.8 nm (@ 1250 nm, 300 g/mm) |
| XY Stage | 200 × 200 mm travel, <3 µm repeatability |
| Minimum Step Size | 1 µm |
| Data Acquisition | DCS300PA digitizer with preamplifier |
| Brand | ZOLIX |
|---|---|
| Model | PMTH Series |
| Cooling Type | Thermoelectric (TE) |
| Detector Type | Side-Window Photomultiplier Tube (PMT) |
| Compatible PMT Models | CR131, R928 |
| Spectral Range | 185–900 nm |
| Peak Wavelength | 400 ± 30 nm |
| Cathode Sensitivity (peak) | 74 mA/W |
| Peak Quantum Efficiency | 25.4% @ 260 nm |
| Gain | 1.0 × 10⁷ |
| Cathode Active Area | 8 × 24 mm |
| Cathode Luminous Sensitivity | 140–250 µA/lm |
| Anode Luminous Sensitivity | 1000–2500 A/lm |
| Typical Anode Dark Current | 3 nA |
| Max Anode Dark Current | 50 nA |
| Photocathode Material | Multi-alkali (S-20) |
| Dynode Structure | Box-and-Grid (9-stage) |
| Window Material | UV-Transmitting Glass |
| Anode Rise Time | 2.2 ns |
| Electron Transit Time | 22 ns |
| Cathode-to-Anode Voltage | 1250 V |
| Cathode-to-Last-Dynode Voltage | 250 V |
| Operating Ambient Temperature | −80 to +50 °C |
| Achievable Cooling Temperature | −10 °C (at 20–25 °C ambient) |
| Dark Count Rate (1 s integration, −10 °C) | 150–250 cps |
| HV Power Supply | Integrated, Low-Ripple, Adjustable Output |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PMTH-S1-(x) |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–4000 cm⁻¹ (laser-dependent) |
| Spectral Resolution | <2 cm⁻¹ (with 1800 gr/mm grating) |
| Spatial Resolution | ~100 µm (at 100 µm core fiber) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ over 8-hour operation |
| Excitation Wavelengths | 405, 514, 532, 633, 670, 671, 785, 808 nm |
| Detector Options | ICCD (gate width <2 ns) or back-illuminated deep-depletion CCD |
| Collection Optics | Cassegrain telescope (f = 1000 mm, optional), Raman fiber probe (NA = 0.22), or custom long-working-distance optics |
| Laser Options | CW diode lasers (e.g., 785 nm, 100 mW) or Q-switched pulsed lasers (e.g., 532 nm, 290 mJ, 10 Hz) |
| Compliance | ASTM E1840, ISO/IEC 17025–compliant system architecture, FDA 21 CFR Part 11–ready data acquisition framework |