Chemical Analysis Instruments
Filter
Showing 5851–5880 of 10340 results
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MMO-220A |
| Drive Principle | Oil-Hydraulic |
| Axis Configuration | Single-Axis (Z-axis fine adjustment) |
| Fine Adjustment Range | 10 mm |
| Minimum Step Resolution | 1 µm |
| Coarse Rotation per Full Turn | 250 µm |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm, 630 g |
| Actuator Unit Dimensions (W×D×H) | 52 × 20 × 35 mm, 38 g |
| Hydraulic Tubing Length | 0.9 m |
| Compatibility | Mounts to standard 3-axis micromanipulators (e.g., MO-202, MN-4, or equivalent ball-joint platforms) |
| Operating Principle | Continuous hydrostatic pressure transmission via incompressible silicone oil |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMS-4000 |
| Pricing | Available Upon Request |
| Brand | MN Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | PF-12 |
| Wavelength Range | 345–690 nm (7 fixed filters) |
| Optical System | Single-beam filter photometer with filter wheel |
| Photometric Range | ±3 E |
| Accuracy | ±1% absorbance |
| Wavelength Accuracy | ±2 nm |
| Bandwidth | 10–12 nm |
| Detector | Silicon photodiode |
| Light Source | Tungsten lamp |
| Sample Cell | 16 mm round cuvettes |
| Data Storage | 200 GLP-compliant measurements |
| Display | Backlit LCD (64 × 128 pixels) |
| Interface | USB 2.0 |
| Power Supply | AA batteries (rechargeable or alkaline), USB bus power, 12 V automotive adapter, or AC adapter |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Compliance | EN 61010-1 (Low Voltage Directive 2006/95/EC), EN 61326-1 (EMC Directive 2004/108/EC), ISO 9001 certified |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC-8810 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Coal Industry Specific |
| Detection Limits | Permanent Gases (N₂, CO₂, O₂) < 10 ppm |
| Analysis Time | ≤ 2 min (including backflush) |
| Modular Configuration | Up to 4 independent GC channels |
| Detector Technology | NEMS-based silicon micro-TCD |
| Flow Control | Electronic Pressure Control (EPC) per channel |
| Temperature Control | Independent oven and column-zone heating per module |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Regional Classification | Domestic (China-Made) |
| Model | GC7890B |
| Pricing | Upon Request |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 (Dual-Detector) |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detector Configuration | Pulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID) |
| Carrier Gas | Ultra-High-Purity Helium Only |
| Linear Range | 10⁵ |
| Detection Limit | Sub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆ |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 Series |
| Instrument Type | Online Gas Chromatograph |
| Detector Configurability | Up to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID) |
| Injection Options | Packed column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector |
| Oven Temperature Range | +4 °C above ambient to 450 °C (1 °C increment) |
| Oven Temperature Stability | ±0.1 °C at 200 °C |
| Oven Programmable Stages | 16 temperature ramps |
| Cooling Rate | 260 °C to 50 °C in ~6 min |
| Temperature Zones | 8 independently controlled zones |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm |
| Display | 5.7-inch color TFT touchscreen |
| Data Interface | Ethernet (IEEE 802.3), PC-controlled operation or standalone mode |
| Remote Capability | Network-enabled remote monitoring, unattended operation, distributed acquisition, centralized control |
| Multidimensional GC Support | Center-cutting and valve-switching configurations enabled |
| Software | Method-driven acquisition with full parameter storage and recall |
| Compliance | Designed for GLP/GMP environments |
| Brand | MNK |
|---|---|
| Model | GC8800-II |
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Control Interface | IEEE 802.3 Ethernet |
| EPC Module | Integrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) |
| Autosampler Compatibility | Dual-tower 24-position liquid autosampler |
| Optional Gas Autosampling | MNK Cylinder & Gas-Phase Autosampler |
| Ancillary Module Support | MNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis |
| Data System | Multi-instrument data aggregation |
| Regulatory Alignment | Designed to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8810 |
| Instrument Type | Online Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Detector Configuration | Up to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD) |
| Communication Interface | Ethernet-enabled Industrial Bus Architecture |
| Compliance Context | Designed for GLP/GMP-aligned environments with audit-ready data handling capabilities |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M-EAO |
| Product Type | Online Dew Point Analyzer |
| Operating Temperature Range | −110 °C to +20 °C (dew point) |
| Accuracy | ±1 °C dew point |
| Repeatability | ±0.5 °C |
| Response Time | 5 min to T90 (dry-to-wet transition) |
| Output Signal | 4–20 mA |
| Power Supply | 24 VDC |
| Sensor | Imported high-stability chilled-mirror or aluminum oxide sensor (application-optimized) |
| Enclosure Rating | Ex db IIC T6 Gb |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Detector Configuration | Dual-detector, multi-column parallel architecture |
| Temperature Control | 8 independent zones, 20-step programmable ramping |
| Advanced Functionality | Built-in back-flush module enabling heart-cutting and column switching |
| Data System | Dedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment |
| Detection Limits (v/v) | PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Dual-Detector Configuration | PDHID + TCD |
| Independent Temperature Zones | 8 |
| Oven Programmed Ramps | 20-step |
| Back-Flush & Heart-Cut Capability | Integrated |
| Detection Limits (v/v) | PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L |
| TCD — O₂ | 49 µL/L, N₂: 70 µL/L |
| PDHID Specifications | Pulsed Discharge Helium Ionization Detector |
| TCD Specifications | Baseline Noise ≤ 20 µV |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MPS950 |
| Product Type | Online Dew Point Analyzer |
| Operating Temperature Range | –100 to 0 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤ ±1 °C |
| Sample Flow Rate | 2–3 L/min (recommended: 2 L/min) |
| Response Time (90%) | 15 min at –10 to –80 °C |
| Pressure Range | 0–1 MPa |
| Ambient Operating Conditions | 5–45 °C, 0–90% RH |
| Output Signal | 4–20 mA |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions | 270 × 132 × 330 mm |
| Weight | ~3 kg |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MQ701-16 |
| Configuration | 16-position gas-tight sampling station |
| Compatibility | Agilent GC systems (native control via Agilent ChemStation/OpenLab), universal TTL/RS-232 trigger interface for cross-platform integration |
| Vacuum Source | Integrated diaphragm vacuum pump (oil-free, zero carryover) |
| Sample Path | Silanized stainless steel tubing with active sulfur resistance |
| Heating | Electrically heated transfer lines (adjustable 40–120 °C) |
| Control | PC-based software with method scheduling, audit trail, and sequence logging |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MQ701-6S |
| Sampling Positions | 6 / 16 / 32 (customizable) |
| Power Consumption | 100 W |
| Power Supply | 220 V, 50 Hz |
| Net Weight | 15 kg (6-position), 25 kg (16-position) |
| Dimensions | 350 × 371 × 270 mm (6-position), 400 × 480 × 630 mm (16-position) |
| Tubing | 1/16″ SilcoNert®-treated stainless steel |
| Interface Options | RS-232, Touch Control, EVENT Trigger, BCD Output |
| Vacuum Source | Diaphragm Pump |
| Compliance | Compatible with ASTM D5504, EPA Method TO-15 & TO-14A, ISO 16000-6 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MS200S |
| Pricing | Available Upon Request |
| Liquid Sample Inlet Pressure Range | 0.69–2.75 MPa |
| Gas Sample Inlet Pressure Range | 0.69–2.07 MPa |
| Temperature Control Range (Heating & Trace Heating) | Ambient +5°C to 230°C |
| Temperature Stability | ±0.1°C |
| Carrier Gas Flow Rate | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Operating Ambient Temperature | −18°C to +65°C |
| Surface Passivation | SilcoTek® SilcoNert®-treated Stainless Steel Tubing |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MY501 |
| Measurement Principle | Potentiometric Electrochemical (Fuel Cell) |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1 %, 0–25 % O₂ |
| Accuracy | ≤1 % FS (for 0.00–10 ppm range) |
| Repeatability | ≤±1 % FS |
| Response Time (t₉₀) | ≤30 s |
| Resolution | 0.1 ppm |
| Sample Flow Rate | 1000 mL/min |
| Inlet Pressure | 0.05–0.1 MPa |
| Output Signals | 4–20 mA / 0–1 V / 0–10 V DC (selectable) |
| Operating Temperature | –5 °C to +45 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Sensor Lifetime | 24 months (at 25 °C, 1 atm, avg. [O₂] < 1000 ppm) |
| Power Supply | DC 12 V |
| Dimensions (W×H×D) | 212 × 290 × 194 mm |
| Weight | ~2 kg |
| Enclosure Fitting | 1/8″ OD compression fitting |
| Calibration Gas | N₂-based standard with 80 % of full-scale O₂ concentration |
| Compliance | Designed for industrial process monitoring per IEC 61000-6-2/6-4 EMI immunity & emission standards |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | PGC-8800 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Detectors | PDHID, TCD, FID |
| Detection Limits (ppb) | H₂ (5), He (5), O₂ (10), N₂ (10), Ar (10), Ne (10), CO (25), CO₂ (5), CH₄ (5), CF₄ (10), C₂F₆ (20), SO₂ (20), F₂ (20), C₃F₈ (20) |
| Temperature Control Accuracy | ±0.01°C |
| Baseline Noise | ≤0.1 mV |
| Analog Outputs | 5–12 channels of 4–20 mA |
| Communication Interfaces | 1× Ethernet, 1× RS-232 (expandable) |
| Display | 10.1″ high-resolution capacitive touchscreen |
| Enclosure | Standard 5U rack-mount chassis (482 × 432 × 222 mm) |
| Brand | MNK |
|---|---|
| Model | PGC-8800 |
| Type | Online Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limits (PDHID) | H₂ (5 ppb), He (5 ppb), O₂ (10 ppb), N₂ (10 ppb), Ar (10 ppb), Ne (500 ppb), CO (25 ppb), CO₂ (5 ppb), CH₄ (5 ppb), CF₄ (10 ppb), C₂F₆ (20 ppb), SO₂F₂ (20 ppb), C₃F₈ (20 ppb) |
| Complementary Detectors | TCD, FID |
| Sample Phase | Gaseous |
| Operating Mode | Continuous Unattended Online Monitoring |
| Origin | Beijing, China |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic |
| Model | Mo Foil |
| Price Range | USD 0.15–1,500 (FOB) |
| Thickness | 0.01–1 mm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MO-10 |
| Actuation Principle | Oil-hydraulic displacement amplification |
| Control Mechanism | Drum-type rotary actuator |
| Total Travel Range | 10 mm |
| Fine Adjustment per Full Knob Rotation | 500 µm |
| Minimum Graduation | 2 µm |
| Hydraulic Tubing Length | 1.5 m |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm |
| Control Unit Weight | 630 g |
| Drive Unit Dimensions (W×D×H) | 30 × 20 × 125 mm |
| Drive Unit Weight | 50 g |
| Mounting Compatibility | Standard 3-axis manual micromanipulator rails (e.g., Narishige MMO-2, MN-4, or equivalent) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | UK |
| Model | Modulab XM PhotoEchem |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | MOL |
|---|---|
| Origin | Germany |
| Model | CS1000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Resistance Furnace |
| Carbon Range | 0.005–100 wt% |
| Sulfur Range | 0.005–20 wt% |
| Sensitivity | 0.01 ppm |
| Accuracy | ±1% of reading |
| Analysis Time | 60–120 s |
| Furnace Power Output | 1 kW |
| Maximum Furnace Temperature | 1550 °C |
| Detector Configuration | Up to 4-channel NDIR cells |
| Compliance | ASTM E1019, ISO 15350, ISO 4935 |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | QuickDrop |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Compatibility | Yes |
| Brand | MONSTR Sense Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Femtosecond Pump–Probe Spectroscopy |
| Spectral Range | 530–950 nm |
| Spectral Resolution | 0.02 nm |
| Temporal Resolution | 0.3 fs |
| Brand | Montana Instruments |
|---|---|
| Origin | USA |
| Model | CryoRAMAN |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 190 nm – mid-IR (down to 150 nm with custom coatings, gratings & detectors) |
| Spectral Resolution | 0.08 nm (CCD), 0.05 nm (PMT) across entire focal plane |
| Spatial Resolution | ≥15 lp/mm @ 50% modulation (center of focal plane) |
| Minimum Raman Shift | 0.8 cm⁻¹ |
| Temperature Range | 4 K – 350 K (600 K optional) |
| Sample Positional Drift | <20 µm (4.2 K–350 K, optical axis) |
| Excitation Wavelengths | 532 nm (standard), 785 nm (optional), customizable UV–NIR–MIR sources |
| Laser Spot Size | 1–3 µm |
| Field of View | >30 µm |
| Objective NA | 0.75 (Cryo-Optic®) |
| Spectrometer Options | FERGIE® (f/4, 80.08 mm FL) or IsoPlane® SCT320 (f/4.6, 320 mm FL) |
| Polarization-Resolved Capability | Yes (interchangeable polarization filtering modules) |
| Electrical Transport Integration | CryoChip16-compatible, 16-channel DC measurement platform |
| Automation | Fully automated cryostation (Cryostation® S100), touch-screen + PC control |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | ≤3 s per spectrum |
| Signal-to-Noise Ratio | 15,000:1 |
| Optical Path Design | Low-volume, heated long/short-path gas cell |
| Gas Cell Temperature Control | ±1 °C |
| Operating Ambient | IP50 (optional IP53) |
| Power Supply | 100–240 VAC ±10%, 50–60 Hz ±3 Hz |
| Power Consumption | 550 W (startup), 200 W (steady-state), +400 W (gas cell heater max) |
| Sample Gas Flow Rate | 0–10 LPM |
| Calibration Gas Requirements | Certified standard gases traceable to NIST or equivalent |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Model | Monoblock |
| Tube Type | Metal-Ceramic |
| Target Materials | Ag, W, Pd, Rh |
| Operating Voltage Range | 10–50 kV |
| Current Range | 0–0.2 mA |
| Max Output Power | 10 W |
| Focal Spot Size | 400 µm |
| Stability | < 1.0% RSD |
| Beryllium Window Thickness | 0.25 mm |
| Max Input Power | 20 W |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −40 °C to +60 °C |
| Weight | 500 g |
| Compliance | RoHS, CE (per IEC 61010-1), FDA 21 CFR Part 1020.40 (X-ray equipment) |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TUB00045 |
| Voltage Range | −4 to 40 kV |
| Current Range | 0–100 µA |
| Max Output Power | 4 W |
| Optional Anode Materials | Ag, W, Pd, Rh, Ta, Au |
| Input Voltage | 7–12 VDC |
| Weight | 450 g |
| Warranty | 1 Year |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TUB00046 |
| Voltage Range | ±4–40 kV |
| Current Range | 0–100 µA |
| Max Power Output | 4 W |
| Anode Target Options | Tungsten (W), Rhodium (Rh), Copper (Cu) |
| Focal Spot Size | 300 µm |
| HV Cable Length Options | 1–11.5 inches |
| Warranty | 12 months |