Chemical Analysis Instruments
Filter
Showing 601–630 of 4337 results
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model Series | Kymera 193i, Kymera 328i, Shamrock 500i, Shamrock 750, Mechelle 5000 |
| Spectral Resolution | 0.02 nm (Shamrock 750) |
| Imaging Resolution | 6000 (Mechelle 5000) |
| Optical Design | Czerny-Turner or Echelle |
| Configuration | Filter-based spectroscopy |
| Platform Compatibility | Ground- and airborne deployment |
| Detector Interface | Dual-input/dual-output architecture |
| Focal Length Range | 193 mm to 750 mm |
| Aperture Range | f/3.6 to f/9.7 |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Spectral Range | 200–975 nm |
| Optical Architecture | Fixed, pre-aligned echelle spectrograph with no moving parts |
| Detector Format | Integrated CCD or sCMOS detector (user-selectable) |
| Resolution | High-resolution echelle dispersion (R ≈ 20,000–40,000 depending on slit and detector configuration) |
| Wavelength Coverage | Simultaneous full-range acquisition without scanning |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Wavelength Range | 200–975 nm |
| Optical Configuration | Fixed-grating, pre-aligned echelle spectrograph |
| Detector Integration | Integrated CCD/CMOS detector option |
| Cooling | Thermoelectric (TE) cooled detector |
| Purge Environment | N₂-purged optical path |
| Temperature Stabilization | Auto-temperature correction system |
| Mechanical Design | Compact, rigid monolithic housing |
| Moving Parts | None |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Shamrock 163i |
| Focal Length | 163 mm |
| f-number | f/3.6 |
| Optical Design | Czerny-Turner |
| Grating Compatibility | Interchangeable ruled and holographic gratings |
| Input Options | Adjustable slit (10–200 µm), fiber optic coupling (SMA905, FC/PC), free-space input |
| Detector Interface | Standard Andor camera mounting (C-mount, F-mount, or direct sensor integration) |
| Wavelength Range | UV-Vis-NIR (dependent on grating and detector choice) |
| Resolution | <0.1 nm (typical, with 1200 grooves/mm grating and 10 µm slit) |
| Stray Light Rejection | <1×10⁻⁴ |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Detector Types | PMT (185–900 nm), Si Photodiode (200–1100 nm), InGaAs (800–1900 nm), PbS (800–2900 nm), InSb (1–5.5 µm), MCT (2–12 µm) |
| Power Supply | High-Voltage PMT Driver |
| Data Acquisition | Single-Photon Counting Module & Analog Digitizer |
| Accessories | Sample Chambers, Filter Wheels, Fiber-Optic Coupling Kits |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Solis |
| Operating Systems | Windows Vista/7/8/10 (32-bit & 64-bit) |
| Development Interfaces | C/C++, C#, VB6, LabVIEW, MATLAB, Linux-compatible SDK |
| Compatible Hardware | Andor CCD/EMCCD/sCMOS cameras, spectrographs, motorized stages, filter wheels, shutters |
| Integration Support | µ-Manager plugin architecture |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-163 |
| Optical Design | Czerny-Turner |
| Focal Length | 163 mm |
| F/# | f/3.6 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.05 nm |
| Stray Light | ≤0.3% T |
| Dispersion | 2.0 nm/mm (with specified grating) |
| Entrance Slit Options | Multiple fixed and adjustable slit widths |
| Grating Mount | Dual-grating turret (standard), up to 3 gratings optional |
| Detector Compatibility | Full integration with Andor CCD, ICCD, and EMCCD cameras |
| Imaging Plane Dimensions | 28 mm × 10 mm |
| Grating Size | 40 mm × 40 mm |
| Coupling Options | SMA fiber port, kinematic flange, motorized shutter, dynamic slit, silver-coated optics (SR-163-SIL variant) |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-303i |
| Application Systems | Transmission & Reflectance Spectroscopy |
| Grating Turret | Triple-grating (motorized) |
| Spectral Resolution | 0.08 nm @ 2400 g/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Wavelength Range | 303–800 nm |
| F-number | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light Rejection | ≤0.3% T (typical), <2.2×10⁻⁵ (peak-to-valley) |
| Focal Length | 303 mm |
| Image Plane Dimensions | 28 mm × 14 mm |
| Slit Width Range | Motorized dynamic slit, up to 12 mm |
| Weight | 20 kg |
| Dimensions (L×W×H) | 394 × 238 × 208 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-500i |
| Spectral Resolution | 0.05 nm |
| Wavelength Range | 180 nm – IR |
| Dispersion | 1.44 nm/mm |
| F/# | f/6.5 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light | 2.6 × 10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Focal Length | 500 mm |
| Entrance/Exit Ports | Up to 2 input and 2 output ports |
| Image Plane Dimensions | 28 mm × 14 mm |
| Physical Dimensions | 550 mm × 343 mm × 206.5 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-750 |
| Focal Length | 500 mm |
| F/# | F/9.7 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.02 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±10 pm |
| Stray Light Suppression | ≤2.6×10⁻⁵ |
| Grating Size | 68 mm × 68 mm |
| Dispersion | 2.6 nm/mm (at 300 nm, 2400 g/mm) |
| Slit Input Options | 1 or 2 |
| Detector Output Ports | 1 or 2 CCD ports + optional slit output |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Turret | 3-position, fully documented per unit |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR193i |
| Spectral Range | 200–1100 nm |
| F/# | 3.6 |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Grating Configuration | Dual-grating turret with RFID-enabled auto-identification |
| Optical Design | Imaging-corrected with toroidal mirrors |
| Detector Interfaces | Dual-output ports for simultaneous UV–NIR CCD/EMCCD/ICCD and InGaAs array or single-point detectors |
| Optional Coating | Silver-coated optics for enhanced NIR/SWIR throughput |
| Interface | USB 2.0, plug-and-play |
| Software Integration | Micro-Manager SDK-compatible spectral acquisition and analysis suite |
| Brand | Andor |
|---|---|
| Origin | Israel |
| Model | SR193i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Range | 200–1100 nm |
| F/# | 3.6 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Focal Length | 193 mm |
| Imaging Optics | Aplanatic toroidal mirrors |
| Spectral Reproducibility | ±75 pm |
| Grating Turret | RFID-enabled, quick-release dual-grating turret |
| Detector Compatibility | Dual-output port for simultaneous CCD/EMCCD or sCMOS detector coupling |
| Slit Output Option | Configurable monochromator mode |
| Microscope Integration | C-mount and SM1-threaded interfaces compliant |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR303i |
| Spectral Range | 303–800 nm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Wavelength Repeatability | ±0.004 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Stray Light Suppression | ≤2.2×10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Input/Output Ports | Configurable (1 or 2 CCD outputs, motorized slit) |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Size | 68 mm × 68 mm |
| Slit Width | Dynamic, up to 12 mm |
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ELS5000 |
| Pricing | Upon Request |
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ELS5000 |
| Pricing | Upon Request |
| Brand | Angstrom (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LUMO |
| Pricing | Upon Request |
| Brand | Angstrom (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LUMO |
| Pricing | Upon Request |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-1000 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 162 positions |
| Reagent Positions | 3–8 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3000 Plus |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, and 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Photomultiplier Tube (PMT) Detector |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm / 0.2 nm / 0.4 nm / 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3700 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ±0.0002 Abs |
| Baseline Drift | ±0.0005 Abs (30 min) |
| Linearity (r) | >0.9995 |
| Detection Limits | NH₃-N: 0.005 mg/L |
| Total N | 0.02 mg/L |
| S²⁻ | 0.005 mg/L |
| NO₂⁻-N | 0.003 mg/L |
| NO₃⁻-N | 0.006 mg/L |
| Kjeldahl N | 0.02 mg/L |
| Quantification Ranges | NH₃-N: 0.02–80 mg/L |
| Total N | 0.1–160 mg/L |
| S²⁻ | 0.02–200 mg/L |
| NO₂⁻-N | 0.012–200 mg/L |
| NO₃⁻-N | 0.03–160 mg/L |
| Kjeldahl N | 0.08–80 mg/L |
| Precision | 0.5–1.0% RSD (at specified concentrations) |
| Measurement Time | 100–280 s (including online digestion for total nitrogen) |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-500 / AJ-900 |
| Sample Tray Configurations | 90-position (86 × 15 mL + 4 × 50 mL) or 51-position (51 × 50 mL) |
| Detector Interface | Photomultiplier Tube (PMT) Compatible |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | AJ-510 |
| Quotation | Upon Request |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016 |
| Sample Capacity | 160 × 2 mL vials |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 10 µL |
| Positioning Accuracy | ±0.3 mm |
| Motion Architecture | Vertical tower with optional expansion tray |
| Needle Wash Cycles | 99 internal rinses per injection |
| Replicate Injections per Vial | up to 99 |
| Injection Speed | configurable down to 0.1 s per injection |
| Injection Depth Range | –2 to 35 mm |
| Sample Tray Encoding | absolute-position optical encoder |
| Communication Protocols | Modbus RTU, USB 2.0, TTL I/O (compatible with major GC vendors) |
| Operating Temperature | –20 °C to 50 °C |
| Storage Temperature | –40 °C to 70 °C |
| Relative Humidity (operating) | 10–90% RH non-condensing |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3016B |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 160 positions |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volumes | 0.5, 1, 5, 10, 25, 50, and 500 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion System | XYZ three-axis robotic arm |
| Needle Wash Cycles | up to 99 |
| Re-injection Repetitions | up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016C |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 24–160 positions (standard 24, expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume Range | 0.5–500 µL (user-selectable) |
| Positioning Accuracy | ±0.1 mm |
| Motion Architecture | Vertical Tower (Z-axis linear actuation) |
| Needle Wash | Internal & External Wall Rinse, Unlimited Cycles |
| Repeat Injection Capability | Unlimited (user-configurable) |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Per-Vial Injection Count | 1–99 |
| Maximum Time Interval Between Injections | 999 min |
| Viscosity Delay | 0–60 s |
| Pre-/Post-Insertion Dwell Time | 0–120 s |
| Needle Penetration Speed | Fast / Slow / Custom |
| Aspiration/Dispense Speed | Fast / Slow / Custom |
| Injection Modes | Conventional, Continuous, Sample+L1, Sample+L1+L2, PTV-compatible |
| Control Interface | TTL-triggered interval control, GC signal reverse-triggering, USB 2.0, Modbus RTU over RS-485 |
| Dual-Tower Injection Time Reproducibility | < 1 ms |
| Barcode Scanning Support | Yes |
| Sample Temperature Control | Optional integrated cooling/heating module |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Storage Humidity | 5–90% RH |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3117 |
| Sample Capacity | 156-position 2 mL vial tray + 15-position auxiliary tray |
| Minimum Injection Volume | 0.01 µL |
| Quantitative Loop Volume | 10 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion Mechanism | Turret-based |
| Needle Wash | Internal Wall Rinse |
| Repeat Injection Cycles | Up to 99 |
| Operating Temperature Range | −20 °C to 50 °C (operational), −40 °C to 70 °C (storage) |
| Relative Humidity Range | 10–90% RH (operational), 5–90% RH (storage) |
| Communication Protocol | Modbus RTU |
| I/O Interface | Configurable digital I/O for GC synchronization |
| Control Modes | Interval-triggered, signal-triggered (TTL/relay), and full PC-based remote control |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3117B |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 20 positions (expandable to 156) |
| Minimum Injection Volume | 0.1 µL |
| Positioning Accuracy | < 0.1 mm |
| Motion Mechanism | Turret-based |
| Needle Wash Mode | Selectable (pre- and/or post-injection) |
| Repeat Injection Count | Up to 99 cycles per sample |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 88 positions |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volumes | 1 mL / 2 mL / 3 mL |
| Positioning Accuracy | <0.1 mm |
| Sampling Mechanism | Quantitative Loop Injection |
| Needle/Line Cleaning | Fully Automated |
| Repeat Injection Cycles per Sample | Up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519-XS |
| Instrument Type | Gas Chromatography (GC) Gas Bag Autosampler |
| Maximum Sample Volume | 5 mL |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volume Range | 0.05–5 mL |
| Positioning Accuracy | RSD < 0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Method | PC-based host software control |
| Needle/Line Cleaning | Integrated pneumatic line purge with inert gas |
| Repeat Injection Count | 1–99 times per sample |
| Sample Tray Capacity | 11 / 28 / 40 positions (expandable to 88) |
| Quantitative Loop & Line Heating Range | Ambient to 150 °C |
| Sample & Standard Dilution Ratio | Up to 1:200 (customizable) |
| Sampling Pump | Max flow 6 L/min |
| Sampling Time Parameters | Max draw time 99 s, max equilibration time 99 s, max purge time 600 s |
| Tubing Material | PTFE |
| Valve Actuator | PEEK body with PI (polyimide) rotor |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |