Chemical Analysis Instruments
Filter
Showing 1681–1710 of 4548 results
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Multiparameter Benchtop pH Meter |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −5.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Range | −2000.00 to +2000.00 mV |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | −20.0 to 135.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point auto-recognized NIST-traceable buffer sets (33 buffers across 7 international standards including NIST, DIN, JIS, USP, and ISO) |
| GLP Compliance | Full audit trail, user ID (10), sample ID (10), timestamped data logging (≥100,000 entries), RS232 interface with printer/PC export (Excel, Word, plain text), 24-hr clock & date stamp |
| Electrode Compatibility | Dedicated protein-, low-ionic-strength-, viscous-, micro-volume-, surface-, and extreme-pH electrodes (HF-resistant, alkaline-resistant, planar, semi-micro, and ultra-micro configurations) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHS-320 Soil pH Meter |
| Instrument Type | Multiparameter |
| Parameter Types | pH, mV, Rel.mV, ORP, ISE, Temperature |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| Temperature Compensation | Automatic (ATC) or Manual (−20.0 to 135.0 °C) |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point, auto-buffer recognition, 7 buffer groups (33 NIST-traceable standards) |
| Data Storage | ≥100,000 entries with GLP-compliant metadata (sample ID, operator ID, timestamp, calibration history) |
| Interface | RS232 with printer/PC bidirectional communication |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHS-320 Solid-Sample pH Meter |
| Instrument Type | Multiparameter |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Range | (−2000.00 to 2000.00) mV |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | (−20.0 to 135.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point, auto-buffer recognition (NIST-traceable standards supported) |
| GLP Compliance | Full audit trail, sample/personnel ID (10 each), timestamped data logging |
| Data Storage | ≥100,000 entries |
| Interface | RS232 with printer export, PC data transfer (Excel/Word/CSV), bidirectional control |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHS-320 Titanium Dioxide pH Meter |
| Instrument Type | Multi-Function pH Meter |
| Parameter Types | pH, mV, Rel.mV, ORP, ISE, Temperature (°C) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Range | (−2000.00 to 2000.00) mV |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | (−20.0 to 135.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point automatic buffer recognition (NIST, DIN, JIS, ASTM-compatible buffers |
| ATC | Automatic & Manual Temperature Compensation |
| GLP Compliance | Full GLP data logging with sample ID (10), operator ID (10), timestamp, calibration history, and electrode diagnostics |
| Data Storage | ≥100,000 measurements with internal non-volatile memory |
| Interface | RS232 serial port (printer output, PC data export to Excel/Word/Notepad, bidirectional control) |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | PHS-320 Ultra-Pure Water pH Meter |
| Price Range | USD 420–690 |
| Instrument Type | Multifunctional |
| Parameter Types | pH, mV, Rel.mV, ORP, ISE, Temperature |
| pH Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | (−20.0 to 135.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | 1–5 point auto-recognized calibration |
| Supported Buffers | 33 NIST-traceable standard solutions across 7 buffer groups (JJG119, DIN 19266/19267, JIS Z8802, USP, ASTM D1293) |
| GLP Compliance | Full audit trail, sample/personnel ID (10 each), timestamped data logging, export-ready formats |
| Data Storage | ≥100,000 records |
| Interface | RS232 with printer/PC bidirectional protocol (Excel/Word/Notepad compatible) |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHS-320 Viscous Sample pH Meter |
| Instrument Type | Multifunctional |
| Parameter Types | pH, mV, Rel.mV, ORP, ISE, Temperature |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| Calibration Standards | NIST-traceable buffers |
| Input Impedance | ≥3 × 10¹² Ω |
| Temperature Compensation | Automatic (ATC) or Manual (−20.0 to 135.0 °C) |
| Data Storage | ≥100,000 entries |
| GLP Compliance | Full audit trail, sample/analyst ID, timestamping, calibration history |
| Connectivity | RS232 with printer export, PC data transfer (Excel/Word/Notepad), bidirectional control |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHS-320 Wastewater pH Meter |
| Instrument Type | Multiparameter |
| Parameter Types | pH, mV, Rel.mV, ORP, ISE, Temperature (T) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−5.000 to 20.000) pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Range | (−2000.00 to 2000.00) mV |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | (−20.0 to 135.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point automatic buffer recognition (NIST, DIN, JIS, ASTM-compatible buffers |
| ATC | Automatic/Manual Temperature Compensation |
| GLP Compliance | Full GLP data logging with sample/personnel ID (10 each), audit trail, timestamping, and export capability |
| Data Storage | ≥100,000 records |
| Interface | RS232 with printer, PC export (Excel/Word/CSV), and bidirectional control |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-320TRIS |
| Instrument Type | Multi-parameter Benchtop Electrochemical Analyzer |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −5.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH (user-selectable) |
| mV Range | −2000.00 to +2000.00 mV |
| mV Resolution | 0.01 / 0.1 / 1 mV (user-selectable) |
| Temperature Range | −20.0 to 135.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | 1–5 point auto-recognized pH calibration |
| Supported Buffers | 33 NIST-traceable standards across 7 international groups (JJG119, ASTM, DIN, JIS, Merck, Mettler Toledo) |
| GLP Compliance | Full audit trail, user ID (10), sample ID (10), timestamped data logging, ISO/IEC 17025-aligned documentation |
| Data Storage | ≥100,000 measurements with metadata |
| Interface | RS232 (printer, PC export, bidirectional control) |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-3C (New Generation) |
| Instrument Type | Benchtop |
| Measurement Parameters | pH, mV, ORP, Temperature |
| pH Accuracy | ±0.01 pH |
| pH Range | −5.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Temperature Range | −5.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥1 × 10¹² Ω |
| Calibration Buffers | China, MT Europe, NIST, MERCK (4 groups, 12 standard solutions) |
| Calibration Points | 1-, 2-, or 3-point auto-recognized calibration |
| Electrode Diagnostics | slope display, stability indicator, equilibrium status |
| Interface | BNC electrode port, thermistor temperature input, RS232 serial output |
| Power | DC 9 V / 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-3C |
| Instrument Type | Benchtop |
| Measurement Parameters | pH, mV/ORP, Temperature |
| pH Accuracy | ±0.01 pH |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥1 × 10¹² Ω |
| Calibration | 1–3 point automatic buffer recognition (NIST-traceable standards) |
| Temperature Compensation | Automatic (ATC) or manual |
| Interface | BNC electrode port, thermistor temperature input, RS232 serial output |
| Power Supply | DC 9 V, 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-3C+ |
| Instrument Type | Benchtop pH Meter |
| Parameter Types | pH, mV, ORP, Temperature |
| Measurement Accuracy | ±0.01 pH |
| pH Range | (–5.00 to 20.00) pH |
| Resolution | 0.01 pH / 0.1 mV |
| Temperature Compensation | Automatic (ATC) and Manual |
| Calibration Standards | NIST-traceable buffers |
| Input Impedance | ≥1 × 10¹² Ω |
| Power Supply | DC 9 V, 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PHS-3C+ |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | −5.00 to 20.00 pH |
| Resolution | 0.01 pH / 0.1 mV |
| Calibration Standards | NIST-traceable buffers (USA) |
| Temperature Compensation | Automatic (ATC) and Manual |
| Input Impedance | ≥1 × 10¹² Ω |
| Interface | BNC electrode port, Pt1000/NTC temperature sensor port, RS232 serial output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-3C+ |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV, ORP, Temperature |
| Measurement Accuracy | ±0.01 pH |
| pH Range | (−5.00 to 20.00) pH |
| Resolution | 0.01 pH / 0.1 mV |
| Temperature Compensation | Automatic (ATC) and Manual |
| Calibration Standards | NIST-traceable buffers |
| Input Impedance | ≥1 × 10¹² Ω |
| Power Supply | DC 9 V, 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Instrument Type | Benchtop |
| Measurement Parameters | pH, mV, Rel.mV, ORP, ISE, Temperature (T) |
| pH Range | (−5.00 to 20.00) pH |
| pH Resolution | 0.01 pH / 0.1 pH (adjustable) |
| pH Accuracy | ±0.01 pH |
| pH Repeatability | 0.01 pH |
| Calibration Points | 1–5 point |
| Supported Buffer Standards | JJG 119 (China), METTLER TOLEDO (EU), Merck (Germany), DIN 19267 (Germany) — 4 groups, 20 total standard solutions |
| mV Range | (−2000.0 to +2000.0) mV |
| mV Resolution | 0.1 mV / 1 mV (adjustable) |
| mV Accuracy | ±0.1% FS or ±0.2 mV |
| Temperature Range | (−20.0 to 135.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Input Impedance | ≥1 × 10¹² Ω |
| Data Storage | 1000 measurement records |
| GLP Compliance | Full GLP support (sample ID, operator ID, calibration history, timestamped audit trail) |
| Interface | RS232 (dual-mode: printer output & PC data transfer) |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-430 |
| Instrument Type | Multiparameter Benchtop pH Meter |
| Measurement Accuracy | ±0.002 pH |
| pH Range | (−10.000 to 20.000) pH |
| Resolution | 0.001/0.01/0.1 pH (adjustable) |
| mV Range | (−2000.00 to +2000.00) mV |
| mV Resolution | 0.01/0.1/1 mV (adjustable) |
| Temperature Range | (−20.0 to 135.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | Up to 5-point pH, 9-point ISE, auto-buffer recognition (NIST, Merck, MT Europe, China standards) |
| Data Storage | 4096 GLP-compliant records |
| Connectivity | USB, RS-232, 0–20 mV analog output |
| Power | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-4C+ |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| pH Measurement Range | 0.000–14.000 pH |
| Resolution | 0.001/0.01/0.1 pH (adjustable) |
| Accuracy | ±0.002 pH ±1 digit |
| Repeatability | 0.001 pH |
| mV/ORP Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| mV Accuracy | ±0.02% FS ±1 digit |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | 1–3 point auto-identification with NIST-traceable standard buffers (pH 4.00, 6.86, 9.18 at 25 °C) |
| Temperature Compensation | Automatic (ATC) or manual, −5.0 to 105.0 °C |
| Interface | BNC electrode port, Pt1000 temperature sensor port, RS232 serial communication |
| Power Supply | DC 9 V / 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-4C+ |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | 0.000–14.000 pH |
| Resolution | 0.001/0.01/0.1 pH (adjustable) |
| mV/ORP Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| Temp Range | −5.0 to 105.0 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration | 1–3 point auto-recognized NIST-traceable buffers (e.g., pH 4.00, 6.86, 9.18 at 25 °C) |
| Temperature Compensation | Automatic (ATC) or manual, −5.0 to 105.0 °C |
| Interface | BNC electrode port, Pt1000 or thermistor temperature input, RS232 serial output |
| Power | DC 9 V, 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-4C+ |
| Instrument Type | Benchtop pH Meter |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | 0.000–14.000 |
| Resolution | 0.001/0.01/0.1 pH (adjustable) |
| mV/ORP Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥3×10¹² Ω |
| Calibration Points | 1–3 point auto-identification with NIST-traceable standard buffers |
| Temperature Compensation | Automatic (ATC) or manual |
| Interface | BNC electrode port, Pt1000/NTC temperature sensor port, RS232 communication port |
| Power Supply | DC 9 V, 300 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PHS-4C+ Titanium Dioxide pH Meter |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | 0.000–14.000 pH |
| Resolution | 0.001/0.01/0.1 pH (adjustable) |
| mV/ORP Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| Temp Range | −5.0 to 105.0 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.3 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Standards | NIST-traceable buffers |
| Temperature Compensation | Automatic (ATC) or Manual |
| Calibration Points | 1–3 point |
| Buffer Sets | Chinese standard set (pH 4.00, 6.86, 9.18 at 25 °C) |
| Interface | BNC electrode port, Pt1000/NTC temperature sensor port, RS232 serial output |
| Power Supply | DC 9 V, 300 mA (center-positive) |
| Brand | FEMA |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FEP 30 |
| Output | DC 0–100 V / 0–6 A (customizable) |
| Voltage Resolution | 0.01 V |
| Current Resolution | 0.001 A |
| Temperature Control Range | Ambient to 100 °C ±1 °C |
| Timer Range | 0–99 h |
| Electrolyte Volume Capacity | 800 mL |
| Cooling | External water-cooled coil |
| Stirring | Integrated magnetic stirrer |
| Sample Exposure Apertures | 15 mm, 20 mm, 30 mm |
| Power Input | AC 220 V, 50 Hz |
| Total Power | 900 W |
| Dimensions (Power Unit) | 292 × 380 × 120 mm |
| Dimensions (Stirrer/Heater Unit) | 240 × 190 × 130 mm |
| Weight | 15 kg |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 1000 Series Fire Detector Test Chamber |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 1100 (smoke-only), 1300 (heat-only), 1400 (combined smoke/heat), 1700 (heat-only with active cooling), 1800 (combined smoke/heat with active cooling) |
| Form Factor | Benchtop |
| Application Domain | Factory QC, R&D Lab, Certification Testing |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJA-1 |
| Price Range | USD 700 – 1,400 (est.) |
| Instrument Type | Multifunctional Electrochemical Analyzer |
| Voltage Input Range | ±1999.9 mV |
| Minimum Resolution | 0.1 mV |
| Accuracy | ±0.025% of reading + 2 digits |
| Input Impedance | >10¹² Ω |
| Sampling Rate | 3–10 Hz |
| Interface | RS-232 (USB adapter optional) |
| Software Platform | Windows-based (11 dedicated application modules) |
| Data Storage | ASCII text files with date-stamped naming convention (e.g., “pHr_YYYY_MM_DD.TXT”, “SPS_YYYY_MM_DD.TXT”) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FJA-6 |
| Price | Upon Request |
| Form Factor | Benchtop |
| Conductivity Range | 1 μS to 100 mS (5 auto-ranging spans) |
| Accuracy | ±1.5% of reading |
| Temperature Compensation Error | <±2% |
| Stability | ±0.1% FS ±1 digit/hour |
| Dimensions | 183 × 130 × 60 mm |
| Weight | <0.5 kg |
| Operating Temp | 0–45 °C |
| RH Limit | ≤85% |
| Power Supply | 5 V DC |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJA-8 |
| Price Range | USD 430–710 (FOB) |
| Measured Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Portability | Handheld |
| Application Environment | Field, Laboratory, Soil Monitoring |
| Conductivity Range | 1 µS/cm – 10 mS/cm (5 auto-ranging decades) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–0.3 mol/L |
| Temperature Range | 0–60 °C |
| Accuracy | ±2% of reading ± 0.01 µS/cm |
| Minimum Resolution | 0.001 µS/cm |
| Data Storage | 200 readings |
| Power Supply | Rechargeable 8.4 V Li-ion battery |
| Dimensions | 183 × 130 × 60 mm |
| Weight | < 0.5 kg |
| Operating Temp. | 0–45 °C |
| Relative Humidity | ≤85% RH |
| Interface | USB for PC data export |
| Software Support | FJA-6 Series PC Application Suite (data logging, calibration history, CSV export) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–120 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 145 psi (1.0 MPa) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU @ 254 nm |
| Fraction Collection | X-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes) |
| Detection Options | Dual-Wavelength UV Detector (D₂ + Tungsten lamp) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000Pro |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–200 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 200 psi (13.8 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Flow Path Configuration | Binary Solvent Delivery |
| Fraction Collection | X-Y Robotic Matrix (135-tube capacity, standard 15 × 150 mm tubes) |
| Detection Options | UV/Vis Detector (D₂ + Tungsten lamp), optional ELSD |
| Column Compatibility | Normal-phase (e.g., silica, 12 g & 25 g), reversed-phase (C18, 40 g), and empty loading columns (12 g) |
| Software Features | Method-based fraction triggering, peak integration & quantitation, audit trail, user management, lamp life monitoring, intensity calibration, TLC-guided method recommendation |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | FlashDoctor-1500 |
| Instrument Type | Medium-Pressure Flash Chromatography System |
| Application Scope | General-Purpose Preparative Purification |
| Flow Rate Range | 0–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Accuracy | ±1.5% |
| Injection Capacity | Manual or Optional Autosampler |
| Injection Volume Range | 0.1–50 mL (via syringe or loop) |
| Temperature Control | Ambient-only (no active column oven) |
| Wavelength Range (DAD) | 200–800 nm |
| Data Acquisition Rate | Up to 20 Hz |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-2000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | <1.5% |
| Maximum Pressure | 300 psi (2.07 MPa) |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Spectral Bandwidth | 8 nm |
| Flow Cell Path Length | 0.3 mm |
| Detection Modes | UV-Vis (DAD), optional ELSD |
| Fraction Collection | 2D X-Y robotic collector (135-tube capacity, standard 15 × 150 mm tubes) |
| Column Compatibility | Reversible normal-phase and reversed-phase (e.g., C18), flash columns up to 40 mm ID |
| Software Compliance | Audit trail, user management, electronic signature support per FDA 21 CFR Part 11 requirements |
| System Architecture | Integrated benchtop unit, ventilated cabinet compatible |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Flex-CLUE |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FLEXA |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–50/100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision | ±0.1% |
| Maximum Pressure | 30/20 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU |
| Data Acquisition Frequency | 3 Hz |