Chemical Analysis Instruments
Filter
Showing 2011–2040 of 4548 results
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NanoLog® |
| Dispersion Element | Grating |
| Slit (Spectral Bandpass) | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Customizable Spectrometer |
| Price | Upon Request |
| Spectral Range | 190–2100 nm |
| Optical Resolution | 10–1 nm (FWHM, configurable per design) |
| Focal Length | 20–140 mm |
| Detector Options | Single-channel PMT, Linear/2D CCD, CMOS, InGaAs, NMOS, PDA arrays |
| Optical Design | Monolithic Czerny–Turner or Crossed-beam configuration with Aberration-Corrected (Type-4) holographic grating |
| Compliance | Designed for integration into ISO/IEC 17025-accredited analytical systems, compatible with FDA 21 CFR Part 11–ready software environments |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QuantaMaster 8000 |
| Wavelength Range | UV–NIR (up to 5500 nm) |
| Monochromator Type | Triple-grating Czerny-Turner with 300 mm focal length |
| Slit Resolution (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Up to 4 integrated sources including PowerArc™ Xe lamp and pulsed lasers (210–2200 nm) |
| Detection Channels | 6 configurable PMT/InGaAs/MCT channels |
| Lifetime Techniques | TCSPC, Strobe, SSTD (Single-Shot Time-Domain), up to 5500 nm |
| Automation | Fully motorized gratings, slits, mirrors, filter wheels, and accessory control via FelixGX software |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | Tunable PowerArc / Tunable KiloArc |
| Output Power (Tunable PowerArc) | Up to 20 mW (wavelength-, grating-, and bandwidth-dependent) |
| Output Power (Tunable KiloArc) | >300 mW (wavelength-, grating-, and bandwidth-dependent) |
| Beam Divergence | 14.5° (PowerArc) / 14.4° (KiloArc) |
| Numerical Aperture (N.A.) | 0.12 |
| Optical Noise | 0.07% RMS |
| Power Stability | ±0.2% (over 8 hours, temperature-controlled environment) |
| Spectral Range | 180–2200 nm |
| Bandwidth Tunability | 0–25 nm (continuously adjustable) |
| Lamp Options | 75 W to 1000 W Xenon arc lamps |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | ≤1% |
| Long-Term Stability (RSD) | ≤2% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm at 200 nm (Constant Resolution Across Full Range) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | VS20 |
| Resolution | ≤6.5 nm (with 50 µm slit) |
| Stray Light | <0.25% @ 260 nm, <0.1% @ 400 nm, <0.2% @ 600 nm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1700 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Scanning |
| X-ray Tube Power | Not Applicable (Rh anode, max 50 kV / 1 mA) |
| Elemental Range | Na to U |
| Detection Limits | Cd ≤ 2 ppm, Pb ≤ 5 ppm, Cl ≤ 50 ppm |
| Sample Chamber Max Size | 460 × 360 × 150 mm |
| X-ray Beam Diameters | Φ1.2 mm and Φ3.0 mm (motorized switching) |
| Detector | High-Purity Silicon XEROPHY Detector |
| Liquid Nitrogen Capacity | 3 L |
| LN₂ Consumption | <1 L/day (only during operation) |
| Optical Magnification | 50× (coaxial with X-ray beam) |
| Software | Automated qualitative/quantitative analysis (fundamental parameters method, calibration curve method, single-point correction) |
| PC Requirements | Pentium IV ≥1.8 GHz, ≥1 GB RAM, ≥120 GB HDD, Windows XP, 17″ monitor, color inkjet printer |
| Ambient Temp | 10–35 °C (optimal), 5–40 °C (operational) |
| Humidity | ≤80% RH at 5–31 °C |
| Power Supply | AC 100/120/220/240 V ±10%, 50/60 Hz |
| Power Consumption | ≤1.3 kVA (system-wide) |
| Weight | ~265 kg (analysis unit only) |
| Dimensions | Analyzer Unit: 610(W) × 750(D) × 500(H) mm |
| Signal Processing Unit | 220(W) × 500(D) × 480(H) mm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-5200WR |
| Sample Environment | Air (Atmospheric) |
| Elemental Range | Na to U |
| Quantification Range | 1 ppm – 99.99% |
| Operating Conditions | 50 kV / 1 mA |
| Repeatability | ±0.1% RSD |
| Spot Size | Standard 400 µm, Optional 10 µm |
| Detector | Silicon Drift Detector (SDD), LN2-free |
| Geometry | Coaxial Optical Microscope Integration |
| Analysis Mode | Non-destructive, No Vacuum Required, No Sample Preparation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-7000V |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Source | Rh anode, 50 kV / 1 mA |
| Spatial Resolution | Down to 10 µm |
| Measurement Range | Na (11) to U (92) |
| Vacuum Modes | Full vacuum & local vacuum (switchable in <5 s) |
| Optical Imaging | Co-axial CCD with macro/micro view |
| Sample Chamber | 300 mm × 300 mm × 80 mm (full vacuum), XY stage: 100 mm × 100 mm |
| Software | SmartMap™ for hyperspectral mapping, INCA™ pulse processor, GLP-compliant data handling |
| Quantification Methods | Fundamental Parameters (FP), single-standard FP, calibration curve, multilayer thin-film analysis (nm–µm scale) |
| Elemental Mapping | Pixel-resolved full-spectrum acquisition, offline reprocessing, RGB overlay, line scan, ROI masking |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-7200WR |
| Detection Principle | Energy Dispersive X-Ray Fluorescence (ED-XRF) |
| Spot Size Range | 10 µm to 1.2 mm |
| Detector Type | Silicon Drift Detector (SDD), Liquid-Nitrogen-Free |
| Maximum Scan Area | 10 cm × 10 cm |
| Optical-Element Image Co-Registration | Yes |
| Elemental Mapping Resolution | ≤10 µm |
| Compliance | ASTM E1621, ISO 8256, IEC 62321-5 (RoHS), USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XGT-9000 |
| Excitation Mode | Single-Wavelength Excitation |
| X-ray Tube Power | 50 W |
| Voltage Range | Up to 50 kV |
| Current Range | Up to 1000 µA |
| Elemental Coverage | Na (11) to U (92) |
| Minimum Spot Size | ≥10 µm |
| Optional Capillary Probes | 15 µm and 100 µm |
| Detector Configuration | Dual-mode — Energy-Dispersive XRF + Transmission X-ray Imaging |
| Sample Chamber Flexibility | Up to 4 configurable measurement atmospheres (air, He, vacuum, N₂) |
| Software Platform | HORIBA X-RAY LAB |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA Nano |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution (TERS mode) | <10 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <0.1 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA PLUS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Brand | HP Spectroscopy |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | hiXAS |
| X-ray Energy Range | 5–12 keV |
| Minimum Detectable Element Concentration | Low to several wt% |
| XAFS Acquisition Time | 3–8 min (depending on sample concentration and normalization requirements) |
| Spectral Resolution (E/ΔE) | Constant 4000 across full energy range |
| Detector | Photon-counting pixelated X-ray detector |
| Monochromator | HAPG-based von Hamos geometry spectrometer |
| Footprint | 2.0 m × 1.0 m |
| Sample Handling | Motorized sample wheel with multi-position mounting |
| Brand | Csi-lab |
|---|---|
| Model | HR-ARPES200 |
| Energy Resolution | ≤1.8 meV |
| Base Temperature | ≤6.0 K |
| Photon Flux | ≥6×10¹¹ ph/s |
| Origin | Jiangsu, China |
| Distribution Type | Authorized Distributor |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | HS-P5 |
| Instrument Type | Portable |
| Power Supply | Internal Rechargeable Battery or External DC Input |
| Sample Position Capacity | 5 Heated Vials |
| Compatibility | Designed for Coupling with BCT ER Series and P8800 Portable GC-MS Systems |
| Cleaning Function | Integrated Tubing Purge Cycle |
| Operational Mode | Headspace Equilibration with Pre-concentration Estimation Algorithm |
| User Interface | Embedded Control Software with Voice Guidance |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-HT |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8°C to 399°C |
| Maximum Ramp Rate | 40°C/min |
| Cooling Rate | 350°C → 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9760B |
| Price Range | USD 42,000 – 70,000 |
| Analysis Cycle | <20 min |
| Measurement Error | <3% |
| Thermal Stabilization Time | <30 min |
| Operating Ambient Temperature | −10 °C to +50 °C |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Oven Temperature Accuracy | ±0.1 °C |
| Detector Temperature Range | 8 °C above ambient to 399 °C |
| Detector Temperature Accuracy | ±0.1 °C |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | 220 V ± 22 V, 50 Hz |
| Max. Power Consumption | ≤2 kW |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | APK1200 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 200 mL/min |
| Tube Capacity | 20 tubes |
| Compliance | HJ 644–2013, HJ 734–2014, HJ 583–2010 |
| Brand | HUANKONG |
|---|---|
| Model | PB-350 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Limit | <1 ppb (for target VOCs) |
| Repeatability | Compliant with ISO 8573-1 and ASTM D6420 standard requirements |
| Weight | ≤3.5 kg |
| Dimensions | 305 × 160 × 127 mm |
| Interface | USB 2.0, Ethernet, Bluetooth 5.0 |
| Power Supply | Internal Li-ion battery (≥8 h continuous operation), 12 V DC input |
| Brand | Huapaikeyi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS10A |
| Temperature Range | +5–150 °C |
| Derivatization Reagent Flow Rate | 0–5 mL/min |
| Reaction Capillary | Stainless Steel, 10 m × 0.2 mm ID |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-100 |
| Sample Capacity | 100-position carousel |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Heating Temperature | Ambient to 250 °C |
| Sample Chilling Temperature | 4–10 °C |
| Cold Trap Temperature | Ambient to −40 °C |
| Water Removal Trap Temperature | Ambient to −30 °C |
| Desorption Ramp Rate | >2000 °C/min (low-voltage controlled) |
| Purge Flow Control | 0–100 mL/min, adjustable with digital readout |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Programmable External Events | 15 independent time-controlled functions (0.1–99 min, timing accuracy <0.1%) |
| Sample Vial Format | Standard 40 mL vials |
| System Dimensions | 580 × 640 × 850 mm (H×W×D) |
| Weight | ~50 kg |
| Power Consumption | <1000 VA |
| Interlock Signal Latency | <2 s |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | TDS-3410 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 10–250 mL/min |
| Tube Capacity | 12 tubes |
| Temperature Control Resolution | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Timer Range | 0–655 min |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HVE |
| Price | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | HyperFlux™ PRO Plus (HFPP) |
| Laser Wavelength | 785 nm |
| Safety | Integrated laser interlocks |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Spectral Resolution | High (maintained under high-throughput conditions) |
| Deployment | Benchtop & In-line Process Monitoring |
| Compliance | FDA 21 CFR Part 11, ATEX/IECEx for hazardous areas |
| Software | SpectralSoft™ v5.x |
| Brand | Elite |
|---|---|
| Particle Size | 5 µm |
| Dimensions | 4.6 mm × 250 mm |
| Stationary Phase | Hypersil GOLD C18 |
| Carbon Load | 10% |
| Pore Size | 175 Å |
| Silica Type | High-Purity Deactivated Silica |
| Endcapped | Yes |
| pH Stability Range (tested) | 1.8–10.6 |
| Aqueous Mobile Phase Compatibility | Stable in 100% aqueous conditions |
| Brand | I-CHEQ |
|---|---|
| Origin | USA |
| Model | F2-9000 |
| Application | Handheld/Field-Portable |
| Element Range | Mg–Pu |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | 120–140 eV |
| Repeatability | 0.1% |
| Detector | High-Resolution Silicon Drift Detector (SDD) |
| Excitation Source | Variable-Voltage (up to 50 kV) Microfocus X-ray Tube with Selectable Anode Materials (Au, Ag, W, Ta, Pd) |
| Cooling | Peltier Semiconductor |
| Operating System | Windows CE |
| Display | Industrial-Grade TFT Color Touchscreen |
| Dimensions (L×W×H) | 233 × 84 × 261 mm |
| Weight (with battery) | 1.46 kg |
| Compliance | Meets IEC 61000-6-3 (EMC), IEC 61000-6-2, ANSI N43.3, and FDA 21 CFR Part 1020.40 for X-ray safety |