Chemical Analysis Instruments
Filter
Showing 1951–1980 of 10669 results
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Sample Handler (KjelSampler) |
| Model | K-376 / K-377 |
| Instrument Category | Kjeldahl Nitrogen Analyzer Accessory |
| Nitrogen Determination Range | 0.02 – 200 mg N |
| Distillation Time per Sample | ≤240 s |
| Repeatability | RSD < 1 % |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 200 mL |
| Nitrogen Recovery Rate | >99.5 % (for 1–200 mg N) |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 505 × 750 × 655 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | K-446 / K-449 |
| Power | 2300 W |
| Heating Positions | 20 |
| Temperature Range | 30–450 °C |
| Temperature Accuracy | ±1 °C |
| Display | LCD |
| Automation Level | Semi-Automatic (K-446) / Fully Automatic (K-449) |
| Acid Vapor Containment | Integrated Sealed Block Design |
| Sample Tube Material | High-Purity Borosilicate Glass (BUCHI Certified) |
| Safety Features | Dual Temperature Limiting per Stage |
| User Interface | Programmable Multi-Stage Temperature Profiles with Countdown Timer and Real-Time Temperature Feedback |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Product Category | Imported Instrument |
| Compliance Standards | AOAC, EPA, ISO, DIN |
| Automation Options | Manual to Fully Automated |
| Safety Features | Integrated Steam Trap, Overpressure Protection, Acid Fume Containment |
| Service Support | Global Technical Assistance, Method Validation Guidance, GLP-Compliant Documentation |
| Brand | BUCHI |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | X-One (One-Six) |
| Instrument Type | In-line |
| Operating Principle | Real-time in-process spectroscopy with fiber-optic coupling |
| Wavelength Range | 900–1700 nm (standard advanced configuration) |
| optional dual-range | 350–920 nm (VIS) and 950–1750 nm (NIR) |
| Scan Rate | 100 spectra per second |
| Spectral Sampling Interval | 3.2 nm |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | SX-Plus |
| Detector | Diode Array |
| Optical Spot Diameter | 30–40 mm |
| Imaging System | Integrated HD CCD camera, 80 µm spatial resolution in visible range |
| Light Source | Dual tungsten-halogen lamps, MTBF 18,000 h (2 × 9,000 h) |
| Environmental Rating | IP65/IP67 |
| Explosion-Proof Option | ATEX/IECEx certified (Ex II 1/2D ta tb IIIC T80°C |
| Dimensions (W×D×H) | 220 × 220 × 135 mm |
| Weight | 6–7 kg |
| Operating Temperature | −10°C to +70°C |
| Ambient Temperature Range | −10°C to +40°C |
| Relative Humidity | <90% RH, non-condensing |
| Vibration Resistance | 0.2 g (0.1–150 Hz) |
| Process Interface Pressure Rating | 30 bar at flange mounting point |
| Power Supply | 110/220 V AC ±20%, 50/60 Hz, 30 W |
| Housing Material | Nickel-plated stainless steel, aluminum heat sink, NBR sealing |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | NIRFlex N-500 |
| Instrument Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 10000–4000 cm⁻¹ (1000–2500 nm) |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | NIRCal |
| Interferometer Type | TeO₂ Wedge Polarization Interferometer |
| Spectral Resolution | 8 cm⁻¹ |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (at 16 scans) |
| Detector | Temperature-Controlled InGaAs |
| A/D Converter | 24-bit |
| Light Source Lifetime | 12,000 h (dual tungsten halogen lamps) |
| Dimensions | 450 × 550 × 250 mm |
| Weight | 25 kg |
| Operating Environment | 5–35 °C, RH < 80% at ≤31 °C (derating to 67% at 35 °C), altitude ≤2500 m |
| Power Supply | 100–230 V ±10%, 50/60 Hz, <350 W |
| Communication Interface | Ethernet (TCP/IP), 100 Mbit/s |
| IP Rating | IP20 |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Benchtop FT-NIR Spectrometer |
| Model | NIRMaster |
| Spectral Range | 10000–4000 cm⁻¹ |
| Resolution | 8 cm⁻¹ |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Interferometer Type | Polarization Interferometer |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (peak-to-peak, baseline-corrected, 5600–6000 cm⁻¹) |
| Detector | Thermoelectrically Cooled Extended-Range InGaAs |
| Light Source | Dual Halogen Lamp Module (MTBF: 12,000 h) |
| Laser | HeNe, 632.992 nm |
| Operating Temperature | 5–35 °C |
| Relative Humidity | <80% at ≤31 °C (linearly decreasing to 67% at 35 °C) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 150 W |
| Enclosure Material | Food-Grade PMMA or Stainless Steel |
| IP Rating | IP54 (optional IP65) |
| Dimensions (W×H×D) | 360 × 420 × 540 mm |
| Weight | ~43 kg (NIRMaster), ~49 kg (NIRMaster Pro) |
| Chemometrics Software | NIRCal |
| Sample Handling | Easy-Spin magnetic rotation stage for heterogeneous samples |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiMate |
| Instrument Type | Laboratory |
| Measurement Principle | Grating-based non-scanning spectrometer with diode array detector |
| Wavelength Range | 400–1700 nm |
| Scan Speed | 10 ms |
| Data Sampling Interval | 10 nm (visible), 7 nm (NIR) |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Autocal |
| IP Rating | IP69 |
| Weight | 23 kg |
| Dimensions (W × D × H) | 260 × 435 × 500 mm |
| Power Consumption | 60 W |
| Operating Frequency | 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % (at ≤31 °C) |
| Storage Temperature | ≤45 °C |
| Altitude Limit | ≤2000 m |
| Measurement Time | Configurable, default 15 s |
| Optical Configuration Options | Standard NIR only |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiScout |
| Instrument Type | Portable |
| Operating Principle | MEMS-based Micro-Electro-Mechanical Systems NIR Spectroscopy |
| Wavelength Range | 1350–2550 nm |
| Scan Speed | 2 seconds per scan |
| Measurement Mode | Reflectance |
| Chemometrics Software | EigenVector |
| Weight | 1 kg |
| Ingress Protection Rating | IP65 |
| Battery | Dual user-replaceable 18650 rechargeable cells |
| Battery Life | ~800 scans (2 s/scan) |
| Wireless Connectivity | Bluetooth v4.2 BLE |
| Optical Spot Diameter | ~10 mm |
| Charging Port | USB-C |
| Typical Signal-to-Noise Ratio | 2000:1 |
| Spectral Resolution | 16 nm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-815 / Pure C-810 |
| Application Level | Laboratory Grade |
| Instrument Category | Low-to-Medium Pressure Preparative LC |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Operating Pressure | 50 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-835 / Pure C-830 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Pressure | 300 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-850 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative LC System |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | RSD < 3% |
| Flow Precision | RSD < 0.5% |
| Maximum Pressure | 300 bar |
| Wavelength Range | ±2 nm (200–800 nm) |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Pure Essential System |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ±1% at 5–250 mL/min |
| Maximum Pressure | 50 bar |
| UV Wavelength Options | Fixed wavelengths at 254, 275, 325, and 365 nm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | Sepacore |
| Pressure Range | Up to 50 bar (725 psi) |
| Flow Rate | 2.5–250 mL/min |
| Column ID Range | 15–100 mm |
| Max Sample Load | 100 g (glass columns) |
| Detector Wavelength | 190–745 nm |
| Gradient Capability | Binary to Quaternary, 0–100% B, linearity ±2% |
| Software | SepacoreControl (PC-based, optional 21 CFR Part 11 compliance) |
| Pump Type | Tri-piston, pulse-free, solvent-compatible with acids/bases/organics |
| Column Options | Glass (coated), polypropylene flash columns, cartridge-based packing systems |
| Fraction Collection Modes | Time-, volume-, or UV peak-triggered |
| Safety Features | Grounded metal fraction collector arm, transparent pressure-rated glass columns, integrated pressure sensors and level monitoring |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Preparative SFC System |
| Model | SFC-250 |
| Flow Rate Range | 0–250 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar (CO₂ and modifier pumps) |
| Detector Options | Diode Array Detector (DAD), Mass Spectrometer (MS), Evaporative Light Scattering Detector (ELSD) |
| Modifier Channels | 4 |
| Injection Loop Volume | 2.5 mL |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 15–30 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| Gradient Capability | Isocratic, binary linear, or step gradients |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Preparative SFC System |
| Model | SFC-50 |
| Flow Rate Range | 1–50 mL/min (including up to 40% modifier) |
| Maximum Pressure | 400 bar |
| Detector Options | DAD, ELSD, Mass Spectrometer (MS) |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 4–16 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| UV Wavelength Range (DAD) | 190–720 nm |
| Power Supply | 230 V ±10%, 50/60 Hz |
| Operating Environment | 15–25 °C, 45–75% RH |
| Dimensions (W×D×H) | 560 × 600 × 880 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SFC-660 |
| Instrument Type | Preparative |
| Flow Rate Range | 0–660 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar |
| Detector Options | Diode Array Detector (DAD), Electrospray Light Scattering Detector (ELSD), Mass Spectrometer (MS) |
| Brand | BUCK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Flame–Graphite Furnace AAS |
| Optical System | Single-beam |
| Monochromator | Ebert-type with selectable slit widths (0.2, 0.7, and 2.0 nm) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) with pulsed self-reversal mode |
| Spectral Resolution | ≤0.3 nm |
| Detection Limit (Cu) | <0.006 mg/L |
| Sensitivity (Cu) | 5 ppm at 1% absorption |
| Precision (RSD) | <0.3% |
| Wavelength Range | 190–900 nm |
| Slit Width Options | 0.2 nm, 0.7 nm, 2.0 nm |
| Lamp Holders | Triple independent lamp turret with preheat and standby control |
| Flame Burner | High-efficiency slot burner with adjustable gas flows (air/acetylene, N₂O/acetylene) |
| Graphite Furnace | Model 220 GF, integrated design with rapid heating (0–3000 °C in <1 s), programmable multi-step temperature ramping, integrated gas purge (Ar/N₂), and optional integrated graphite furnace autosampler (220AS) |
| Sample Introduction | Pneumatic nebulizer with high-efficiency spray chamber and corrosion-resistant glass bead impactor |
| Software Interface | Onboard microcomputer controller with preloaded method library for >60 elements |
| Dimensions (W×D×H) | 1016 × 305 × 305 mm |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | BUCK |
|---|---|
| Origin | USA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Wavelength | 253.7 nm |
| Detection Limit | 10 pg/L (ppt) under controlled clean-lab conditions |
| Sample Cell Path Length | 400 mm fused silica window |
| Background Correction | Online Deuterium Lamp (D₂) |
| Output Interfaces | RS-232 serial port, analog output (0–1 V or 4–20 mA) |
| Sample Introduction | Air-driven purge-and-trap with integrated desiccant and charcoal filtration |
| Dimensions (W×D×H) | 991 × 279 × 305 mm |
| Weight | 21 kg |
| Power Requirement | 220 V, 50 Hz, 80 W |
| Compliance | Fully compliant with U.S. EPA Method 245.1 |
| Calibration | Up to 8-point linear or quadratic calibration curves |
| Operational Features | Quick-Purge button for flow-cell cleaning, Peak-Picker peak-area integration, GLP-ready data handling |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PFP-7 |
| Price Range | USD 6,800 – 13,600 |
| Power Supply | 90–125 V or 190–250 V, 50/60 Hz |
| Air Requirement | Oil-free, 6 L/min at 1 kg/cm² (14 psi) |
| Fuel Compatibility | Propane, Butane, Natural Gas, or LPG |
| Measurement Range | 0–199.9 mmol/L (Na/K), 0–199.9 ppm (Li) |
| Repeatability | ≤1% CV for 20 consecutive 50.0 mmol/L Na readings |
| Linearity | <2% deviation at 3 ppm Na/K + 5 ppm Li set to 100% |
| Interference | <0.5% cross-sensitivity among Na, K, Li |
| Recorder Output | 1.00 V at 100.0 reading |
| Dimensions | 420 × 360 × 300 mm |
| Weight | 8 kg |
| Brand | Bunkoukeiki |
|---|---|
| Origin | Japan |
| Model | KV-202 |
| Instrument Architecture | Dual-wavelength |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 120–400 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light (S.L.) | ≤0.001% T |
| Light Source | 30 W Deuterium Lamp |
| Sample Format | Rectangular, 3×3 mm to 12×12 mm (min–max), Thickness: 0.1–0.3 mm |
| Measurement Repeatability | ±0.3% T |
| Optical Configuration | Dual-beam with Reference Channel Compensation |
| Monochromator | KV-200 Purgeable/High-Stability Vacuum UV Monochromator |
| Brand | BWB |
|---|---|
| Origin | United Kingdom |
| Model | FL |
| Detection Range | Na: 0.1–1000 ppm |
| K | 0.05–1000 ppm |
| Li | 0.1–1000 ppm |
| Ca | 2.5–1000 ppm |
| Detection Limit | Na/K: 0.02 ppm |
| Li | 0.05 ppm |
| Ca | 1.0 ppm |
| Response Time | <15 s |
| Repeatability | <1% RSD (at ≤100 ppm, n=20 over 10 min) |
| Sample Uptake Rate | 3.0–5.5 mL/min |
| Air Supply | Integrated silent air compressor (switchable to external source) |
| Compliance | CE-marked |
| Data Interfaces | RS232 and USB |
| Calibration Modes | Two-point, multi-point, and multi-ion calibration |
| Display Units | ppm, mg/L, mmol/L, meq/L |
| Safety Features | Flame-out detection, auto-shutdown, power-on self-diagnosis |
| Brand | BWB |
|---|---|
| Origin | United Kingdom |
| Model | BWB FL |
| Detection Range | Na: 0.05–1000 ppm, K: 0.05–1000 ppm, Li: 0.1–1000 ppm, Ca: 2.5–1000 ppm, Ba: 5–1000 ppm |
| Detection Limit | Na/K: 0.02 ppm, Li: 0.05 ppm, Ca: 1.0 ppm, Ba: 2.0 ppm |
| Response Time | <15 s |
| Repeatability | CV <1% at 100 ppm (n=20, >10 min post-stabilization) |
| Sample Uptake Rate | 3.0–5.5 mL/min |
| Air Supply | Integrated silent air compressor (switchable to external source) |
| Compliance | CE-marked, GLP-compliant architecture, FDA 21 CFR Part 11-ready software support |
| Brand | BWB |
|---|---|
| Origin | United Kingdom |
| Model | BWB-XP |
| Detection Elements | Na, K, Li, Ca, Ba |
| Calibration Modes | Two-point, Multi-point, Multi-ion |
| Output Options | 0–1 V analog, RS232, USB |
| Air Supply | Integrated silent air compressor (switchable to external source) |
| Sample Uptake Rate | 3.0–5.5 mL/min |
| Repeatability | CV <1% at ≤100 ppm over 20 injections (≥10 min post-stabilization) |
| Detection Limits | Na/K: 0.02 ppm |
| Li | 0.05 ppm |
| Ca | 1.0 ppm |
| Ba | 10 ppm |
| Linear Range (multi-point) | Na/K: 0.05–1000 ppm |
| Li | 0.1–1000 ppm |
| Ca | 2.5–1000 ppm |
| Ba | 30–3000 ppm |
| Response Time | <15 s (from sample introduction to stable signal) |
| Drift | ≤1% after 30 min stabilization |
| Interference (Na/K/Li at <100 ppm) | <0.5% |
| Display Mode | Real-time simultaneous readout of all five elements (ranked high-to-low) |
| Software | FP-PC v3.x with GLP-compliant reporting, audit trail, data export (up to 10-sample reports), operator/sample metadata tagging, network archiving |
| Compliance | CE-marked |
| Brand | Byonoy |
|---|---|
| Origin | Germany |
| Model | Absorbance One |
| Wavelength Range | 340–1000 nm |
| Optical Density Range | Up to 5.0 OD |
| Measurement Speed | <1 s per reading |
| Sample Volume Compatibility | 50 µL (cuvette), 400 µL (semi-micro), 1000 µL (micro) |
| Detection Principle | Fixed-grating UV-Vis absorption spectroscopy |
| Interface | USB-C & Bluetooth 5.0 |
| Software | Absorbance One Desktop & Mobile App (Windows/macOS/iOS/Android) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation environment |
| Power | Rechargeable Li-ion battery (up to 8 h continuous use) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.1–200 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% RSD |
| Sample Mass | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Linear Range | 0.1–200 mg N |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Kjeldahl Nitrogen Determinator |
| Model | VAPODEST® 200 |
| Automation Level | Semi-Automatic |
| Nitrogen Range | 0.1–200 mg |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% |
| Sample Weight (solid) | ≤5 g |
| Recovery Rate | 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Compatible Acid Titration Range | Universal (any standard acid concentration) |
| Key | Brand: Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CKJF-4G |
| Price Range | USD 2,650 – 2,950 |
| Compliance | GB/T 4334–2020, ASTM A262–2015 |
| Heating Capacity | 2000 W total (4 × 500 W independent stations) |
| Max Operating Temperature | 400 °C |
| Simultaneous Samples | 4 |
| Control System | PLC + PID with touchscreen HMI |
| Cooling | Integrated reflux condensation system (no external water source required) |
| Safety Features | Dry-run alarm, overtemperature cutoff, power-interruption resume function |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Calorsito |
| Price Range | USD 70,000–140,000 |
| Instrument Type | Portable |
| Application Domain | Academic & Research Laboratories (Universities, Institutes) |
| Operating Principle | Photothermal Infrared Imaging Spectroscopy |
| Wavelength Range | 400–950 nm (7 discrete LED wavelengths: 400, 460, 525, 660, 730, 840, 950 nm) |
| Scan Speed | 1 sample per minute |
| Data Sampling Interval | Not applicable (single-shot thermal transient acquisition) |
| Sample Mode | Contactless, non-contact reflective/transmissive mode |
| Chemometrics Software | Integrated Calorsito Analyze Suite (PCA, PLS regression, spectral unmixing) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-grade NIR Spectrometer |
| Model | CA-HM |
| Optical Design | Grating Scanning System |
| Wavelength Range | 780–2526 nm |
| Scan Speed | 100 scans per minute |
| Data Sampling Interval | 1 s |
| Measurement Modes | Reflectance & Transmission |
| Chemometric Algorithm | Peak Cross-Correlation Method |
| Application Scope | Academic Research, Food Quality Control, Nutrition Labeling, R&D Laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ADC 3 |
| Instrument Type | Automatic Thin-Layer Chromatography (TLC) Development System |
| Operation Mode | Fully Automated |
| Sample Format | HPTLC plates up to 20 × 10 cm |
| Chamber Configuration | Dual-saturation chambers with integrated RH control |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11 compliant |
| Software Control | visionCATS v3.x or later |