Chemical Analysis Instruments
Filter
Showing 1981–2010 of 10669 results
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | AMD 2 |
| Instrument Type | Thin-Layer Chromatography (TLC) Multiple Development System |
| Compliance | GLP/GMP-Compliant |
| Control | Programmable, CCD-Monitored |
| Solvent Capacity | Up to 5 solvents |
| Development Stages | Multi-step, Gradient Elution Capable |
| Max. Separation Density | ~40 components within 80 mm |
| Automation Level | Fully Automated Pre-saturation, Development, Drying |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ATS 4 |
| Instrument Type | Automatic Thin-Layer Chromatography Sampler |
| Sampling Modes | Contact (spot) and Non-contact Pneumatic Spray (band/square) |
| Sample Volume Range | 100 nL – 1 mL |
| Precision | ±1 nL / ±2 nL / ±10 nL (for 10 µL / 25 µL / 100 µL syringes) |
| Plate Capacity | Up to 20 × 20 cm, thickness up to 4 mm |
| X-axis Resolution | 0.1 mm/step (80 steps/mm), travel 5–195 mm |
| Y-axis Resolution | 0.1 mm/step (40 steps/mm), travel 5.0–195.0 mm |
| Sample Carrier | 66 × 2 mL vials (12 × 32 mm) or optional 96-well microtiter plate |
| Operating Pressure | 4–6 bar (65–87 psi), compressed air or nitrogen |
| Gas Flow Rate | 0.2–0.3 L/min (spot mode) |
| Integrated Heating Function | Yes |
| Syringe Options | 10 µL, 25 µL, 100 µL |
| Onboard Microprocessor Control | Yes |
| Software Interface | winCATS v1.4.12 or higher |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | BioLuminizer® 2 |
| Instrument Type | TLC Imaging System |
| Detector Technology | Cooled CCD with 65% Quantum Efficiency |
| Data Depth | 16-bit |
| Pixel Resolution | High Spatial Resolution (Optimized for TLC Plate Detail Capture) |
| Application Focus | Bioluminescent Bioautography Coupled with Planar Chromatography |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Derivatizer |
| Operation Mode | Automatic |
| Instrument Type | Preparative Thin-Layer Chromatography System |
| Compliance | Designed for GLP-compliant laboratories |
| Solvent Compatibility | All conventional organic and aqueous solvents |
| Reagent Consumption | ~3 mL for 20 × 10 cm plates, ~4 mL for 20 × 20 cm plates |
| Enclosure | Sealed, fume-controlled chamber |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | HPTLC PRO |
| Instrument Type | Preparative TLC System |
| Operation Mode | Fully Automatic |
| Sample Capacity | Up to 75 samples per run |
| Plate Capacity | Up to 5 TLC plates simultaneously |
| Solvent Systems | Up to 3 different developing solvents in one sequence |
| Software Compliance | FDA 21 CFR Part 11 compliant |
| Module Dimensions | 384 × 550 × 510 mm (W × D × H) |
| Brand | CAMAG (distributed by JHT / Yichenghengda) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | CAMAG TLC Systems (e.g., ATS 4, Linomat 5, Nanomat 4, ADC 2, AMD 2, TLC Visualizer 2, TLC Scanner 4, TLC-MS Interface 2, visionCATS 5) |
| Pricing | Upon Request |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Linomat 5 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Regulatory Compliance | IQ/OQ Qualified |
| Software Integration | visionCATS v3.x or later |
| Application Environment | GLP/GMP-Compliant Laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Kit Type | Standard TLC Basic Toolset |
| Application | Preparative and Analytical TLC |
| Compliance | Designed to Support ASTM D7925, ISO 17025–Compliant Workflows |
| Software Integration | Compatible with CAMAG VisionCats (Optional) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Scanner 4 |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp (automatically switchable) |
| Wavelength Reproducibility | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Sample Stage Dimensions | 200 × 200 mm |
| Scanning Speed | 1–100 mm/s |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Visualizer 3 |
| Light Sources | 254 nm short-wave UV (epi-illumination), 366 nm long-wave UV (epi-illumination), white light (epi-illumination and trans-illumination) |
| Camera Sensor | High-resolution industrial CMOS |
| Software Platform | visionCATS v3.x or later |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC-MS Interface 2 |
| Instrument Type | TLC–MS Coupling Interface |
| Compatibility | Universal LC-MS Systems (ESI, APCI, MALDI sources) |
| Operation Mode | Online and Offline Elution |
| Solvent Consumption | Low (≤ 200 µL per band) |
| Positioning Accuracy | ≤ ±50 µm |
| Washout Function | Integrated reverse-flow purge to prevent channel clogging |
| Sample Recovery | Direct collection into vials (1.5 mL or 2 mL) for downstream analysis (NMR, FTIR, ESI-MS, MALDI-MS) |
| Brand | Cambridge Sensotec |
|---|---|
| Origin | United Kingdom |
| Model | Rapidox 6100 |
| Gas Measurement Range | SF₆ 0–100% (±0.5% FS), H₂O −60 to +20 °C dew point (±2 °C), SO₂ 0–100 ppm (±2%), HF 0–25 ppm (±1 ppm), CF₄ 0–80% (±1%), O₂ 0–100% (±1%) |
| Analysis Time | 3–5 minutes per sample |
| Enclosure | IP66-rated Peli™ carry case |
| Weight | 17 kg |
| Internal Compressor Output | 10 bar |
| Battery Life | Up to 8 hours (Li-ion) |
| Display | 7-inch full-color touchscreen |
| Data Export | USB flash drive (Excel-compatible .csv format) |
| Onboard Thermal Printer | Yes |
| Language Options | Multi-language UI with password-protected access |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | AKONIS |
| Instrument Type | Magnetic Sector SIMS |
| Certification | SEMI S2/S8, E4, E5, E39, E84 Compliant |
| Automation Level | Full In-Line Integration |
| Minimum Measurement Spot Size | 20 µm |
| Positioning Accuracy | < 2 µm |
| Primary Ion Energy Range | < 150 eV (EXLIE Column) |
| Wafer Handling | Full-Size Patterned & Blank Wafer Compatible |
| Cost of Ownership | Optimized for High-Volume Semiconductor Fab Deployment |
| Regulatory Alignment | Designed for GLP/GMP-aligned process control environments |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | IMS 1300-HR3 |
| Primary Beam Energy | 2–15 keV |
| Mass Range | 1–600 amu |
| Mass Resolution | 40,000 |
| Mass Analyzer Type | Magnetic Sector |
| Detector System | 10¹² Ω Faraday Cup + Multi-Collector Array |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | IMS 7f-Auto |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Primary Ion Beam Energy Range | 1–15 keV |
| Mass Range | 1–360 Da |
| Mass Resolution (M/ΔM) | >20,000 |
| Ion Sources | O₂⁺ and Cs⁺ reactive primary ion sources |
| Depth Profiling Capability | High depth resolution & high dynamic range (>10⁶) |
| Automation | Fully motorized sample storage chamber with auto-load/unload, coaxial primary ion gun, remote operation support |
| Detection Limit | Sub-ppq (parts-per-quadrillion) for selected elements in matrix-matched standards |
| Reproducibility | RSD < 0.5% for repeated analyses under standardized conditions |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | IMS 7f-GEO |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Primary Beam Energy | 1–23 keV |
| Mass Range | 1–360 Da |
| Mass Resolution (M/ΔM) | <20,000 |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | IMS Wf / SC Ultra |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Primary Beam Energy Range | 150 eV – 13 keV |
| Mass Range | 1–360 Da |
| Mass Resolution (M/ΔM) | 20,000 |
| Sample Stage Capacity | Up to 300 mm wafer (IMS Wf) |
| Automation | Fully motorized sample transfer between load lock and analysis chamber |
| Compliance | Designed for GLP/GMP-aligned semiconductor process control environments |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | NanoSIMS 50L |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Primary Ion Beam Spot Size | ≥0.5 µm with ion current density ≥100 mA/cm² |
| Mass Range | >238 |
| Mass Resolution (M/ΔM) | >6000 |
| Brand | Cameca |
|---|---|
| Origin | France |
| Model | QUAD4550 |
| Instrument Type | Quadrupole SIMS |
| Primary Ion Beam Energy Range | 250 eV – 5 keV |
| Mass Range | 1–350 Da |
| Mass Resolution | Not Available |
| Base Pressure | ≤1×10⁻¹⁰ mbar (≤1×10⁻⁸ Pa) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Capel-205 |
| Pricing | Upon Request |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cathodeon |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | CCD Interface Flange |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CD-10 |
| Price Range | USD 280–420 |
| Instrument Type | Multifunctional pH Controller |
| Measurement Range | 0–14 pH |
| Resolution | 0.01 pH |
| Input Impedance | >10¹² Ω |
| Output Signals | 4–20 mA analog output |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | CD-12 |
| Price | Upon Request |
| Brand | CDP |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Type | Authorized Distributor |
| Model | ExciPro |
| Multichannel Visible Probe Range | 350–1000 nm |
| Multichannel IR Probe Range | 900–1600 nm |
| Single-Channel Probe Range | 250–2500 nm |
| Max Pump–Probe Delay | 2.0 ns (4.0 ns optional double-pass) |
| Optical Delay Step Resolution | 1.56 fs |
| Max Repetition Rate (Multichannel) | 1 kHz |
| Temporal Resolution | < 100 fs |
| Detection Modes | Multichannel & Single-Channel ΔOD |
| Excitation Source | Integrated SHG + All-Reflective White-Light Continuum Generator |
| Software | ExciPro 2.5 (acquisition, transient spectral analysis, chirp correction) |
| Compliance | Designed for GLP-compliant ultrafast spectroscopy workflows |
| Brand | CDP |
|---|---|
| Origin | Russia |
| Model | FOG100 |
| Spectral Range | 320–1600 nm (excitation-dependent) |
| Repetition Rate | 1 kHz–10 kHz (DA), 100 kHz–100 MHz (DX) |
| Max Gate-Excitation Delay | 2.0 ns (optional up to 6.0 ns) |
| Minimum Delay Step | 1.56 fs |
| Temporal Resolution | < 100 fs |
| Dynamic Range | > 10⁵ |
| Monochromator | Computer-Controlled Dual Grating |
| Capabilities | Fluorescence Anisotropy, Time-Resolved Kinetics (solutions, solids, thin films) |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6150 |
| Pyrolyzer Type | Filament-Heated Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Time | <18 s (from 650 °C to <50 °C, gas-free) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| GC Trigger Support | Per-step synchronized GC start signal |
| Sample Tube | Reusable fused-silica quartz tube |
| Optional Autosampler | 48-position |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6200 |
| Pyrolyzer Type | Filament (Wire) Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Rate | From 650 °C to <50 °C in ≤18 s (no cryogenic gas required) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| Sample Capacity | 48-position auto-sampler (optional) |
| Operating Interface | Integrated touchscreen with one-touch start |
| Heating System | Platinum RTD-integrated resistive filament |
| Atmosphere Control | Switchable carrier/reactive gases (e.g., He, air) |
| Modes | Direct-to-GC and Cold Trap (cryo-trap optional) |
| Software-Controlled Mode Switching | Yes |
| Optional Functions | Thermal Desorption, Dynamic Headspace, Electronic Flow Control, Spectral Library Integration |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 7350 |
| Instrument Type | Aqueous VOC Analyzer |
| Sample Capacity | 72-position tray |
| Trap Temperature | Ambient (Room-Temperature Capture) |
| Purge Heater Temperature | Adjustable up to 100 °C |
| Chiller Temperature | Not applicable (no sample refrigeration) |
| Internal Standard Delivery | 2 µL quantitative loop |
| Moisture Removal | Integrated, flow-path-isolated online water trap |
| System Inertness | Ultra-inert fused-silica and SilcoNert®-treated stainless-steel tubing throughout |
| Foam Detection | Real-time optical foam sensor for overfoaming prevention |
| GC/GC–MS Compatibility | Universal interface (standard 1/16″ OD SS transfer line, pressure-tight fittings) |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 7450 |
| Instrument Type | Water & Soil VOC Analyzer |
| Sample Capacity | 72-position |
| Trap Temperature | Ambient (Room-Temperature Capture) |
| Purge Heater Temperature | Up to 100 °C |
| Sample Chilling Temperature | 4 °C |
| Internal Standard Delivery | 2 µL Quantitative Loop |
| Moisture Removal | Integrated On-line Dual-Path Dehumidification |
| System Inertness | Entire Fluid Path Constructed of SilcoNert®-Treated Stainless Steel and Fused Silica |
| Foam Detection | Real-time Optical Foam Sensor |
| Sample Compatibility | Aqueous Matrices, Soil/Sediment Slurries (via Methanol Extraction), and Solid Samples with Spiking Protocol |