Chemical Analysis Instruments
Filter
Showing 241–270 of 4194 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Analytical LC System |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | up to 5 mL/min (with G7120A and G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Column ID Reader | Optional |
| Solvent Reservoir Capacity | 4 standard, up to 15 with optional Solvent Selection Valve |
| Injection Volume Range | 0.1–100 µL (standard), 0.1–1500 µL (with Multi-Draw Kit) |
| Fraction Capacity | up to 384 fractions (4 × 96-well plates or 216 glass tubes) |
| Delay Volume Sensor | Integrated, auto-calibrating |
| Temperature Zones | 2 (with G7116B column compartment), 1 (with vial sampler-integrated column oven) |
| Pump Type | Binary Gradient Pump |
| System Dimensions (W × D) | 980 × 468 mm |
| Power Supply | 100–240 VAC |
| Software Platform | Agilent OpenLab CDS ChemStation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 1290 Infinity III Bio LC |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal for biopharmaceutical and biomolecular analysis |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | 1300 bar |
| Sample Capacity | Up to 6144 positions (microplate drawer) |
| Injection Volume Range | 0.001–500 µL (0.1–1500 µL with Multi-Draw Kit) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Temperature Control Range (optional integrated chiller/heater) | 4–40 °C |
| Sample Tray Flexibility | Three-height drawer configuration supporting vials and microplates (including shallow-format plates) |
| Carryover | <9 ppm with optional multi-wash and needle seat backflush |
| Sample Path Material | Biocompatible (low-binding, inert surfaces) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Online Sample Manager |
| Instrument Type | HPLC Autosampler for Biopharmaceutical Applications |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Maximum System Pressure | 1300 bar |
| Temperature Control Range (Optional Integrated Thermostat) | 4–40 °C |
| Dilution Ratio | Up to 1:1000 |
| Sample Handling Modes | Flow-through injection, FEED (Fast Exchange and Dilution) injection, Retention mode with quenching and pre-processing capability |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 1290 Infinity III Bio-Online |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose with PAT-focused bioprocess monitoring |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.001–500 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Diode Array Detector |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | < ±3 µAU (10 mm flow cell, 1 s response time) |
| Signal Channels | Up to 8 simultaneous wavelength channels |
| Spectral Acquisition Rate | Up to 240 Hz |
| Optical Path Length Options | 10 mm (standard), 60 mm (high-sensitivity flow cell) |
| Baseline Drift | < ±0.6 µAU/cm (60 mm flow cell) |
| Linear Dynamic Range | Up to 2.5 AU (standard) |
| Slit Width Programmability | 1–8 nm |
| Temperature Control | Electronic Temperature Control (ETC) with RFID-tracked flow cell and lamp modules |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Diode Array Detector FS |
| Detection Principle | UV-Vis Absorbance Spectroscopy via Photodiode Array |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | ±0.6 µAU/cm (with 60 mm pathlength flow cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific signals |
| Sampling Rate | Up to 240 Hz |
| Flow Cell Options | MaxLight™ cartridge flow cells (10 mm and 60 mm pathlengths) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatibility | Integrated with Agilent 1290 Infinity III LC Systems and Third-Party HPLC Platforms |
| Sensitivity | Sub-nanogram detection capability for non-UV-absorbing analytes |
| Temperature Control Range | Peltier-cooled evaporator, 10–80 °C |
| Dynamic Range | Four decades (10⁴) |
| Reproducibility | RSD < 2% (n ≥ 6 injections, standard test conditions) |
| Response Time | < 0.1 s |
| Data Acquisition Rate | Up to 100 Hz |
| Gas Flow Control | Programmable, real-time nitrogen or air flow (0–3.0 L/min) |
| Solvent Compatibility | Fully compatible with gradient elution using volatile and semi-volatile mobile phases including acetonitrile, methanol, THF, and aqueous buffers — DMSO-free operation enabled |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III HDR-DAD |
| Instrument Type | Conventional Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose impurity profiling and trace-level quantitation |
| Flow Rate Range | Up to 5 mL/min (G7120A pump module) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Product Origin | Imported |
| Model | 1290 Infinity III MCT |
| Temperature Control | Peltier-based cooling and heating |
| Temperature Range | −20 °C below ambient to 110 °C |
| Maximum Column Capacity | 8 × 10 cm or 4 × 30 cm columns |
| Pressure Rating | 1300 bar |
| Column Identification | RFID-based tracking for up to 8 columns |
| Door Orientation | 90° or 180° configurable, removable for full access |
| Quick Connect Compatibility | InfinityLab Quick Connect fittings and thermal exchangers |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III High-Throughput |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) / Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Instrumentation |
| Flow Rate Range | Up to 5 mL/min (with G7120A & G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Temperature Control Zones | Dual-zone (G7116A/B) |
| Solvent Selection Capacity | 4 standard, up to 15 with optional Solvent Selection Valve |
| Column ID Reader | Optional |
| Column Capacity | 8 |
| System Dimensions (W × D) | 435 mm × 568 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 1290 Infinity III LC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) / Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical chromatography |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | up to 1300 bar |
| Injection Volume Range | 0.1–100 µL (expandable to 0.1–1500 µL with Multi-Draw Kit) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Method Development System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal Method Development Platform |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (0.1–1500 µL with multi-draw kit) |
| Temperature Control Zones | 2 standard (up to 8 when clustering up to four MCTs) |
| Solvent Selection Capacity | up to 26 solvents (with two external solvent selection valves) |
| Column Capacity | 8 columns per MCT (up to 32 columns with clustered MCT configuration) |
| Column ID Reader | Optional |
| BlendAssist Functionality | Enabled with G7104A pump |
| Power Supply | 100–240 VAC |
| Width | 435 mm |
| Depth | 468 mm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Method Transfer |
| Instrument Type | Conventional and Ultra-High-Performance Liquid Chromatograph (HPLC/UHPLC) |
| Application Scope | General-purpose chromatographic analysis |
| Flow Rate Range | Up to 5 mL/min (with G7120A and G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (expandable to 0.1–900 µL with optional extended range kit |
| Temperature Control | Dual-zone capability (G7116A/B thermostatted compartments) |
| Solvent Selection | Up to 4 solvents standard |
| Column ID Reader | Optional |
| Column Capacity | 8 positions |
| Dimensions (W × D) | 435 mm × 468 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multimethod |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical laboratory |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Solvent Capacity | up to 26 solvents (with two external solvent selection valves) |
| Column Capacity | 8 columns (expandable to 32 via Multi-Column Thermostat clustering) |
| Temperature Zones | 2 standard (up to 8 with clustered MCT configuration) |
| Column ID Reader | Optional |
| BlendAssist Functionality | Enabled with G7104A pump |
| Power Supply | 100–240 VAC |
| Environmental Certification | My Green Lab ACT Label (Audited for Accountability, Consistency, Transparency across lifecycle) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Carryover | < 9 ppm |
| Temperature Control Range (Optional Integrated Chiller/Heater) | 4–40 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Online SPE |
| Instrument Type | UHPLC–Online Solid-Phase Extraction Coupled System |
| Application Scope | General-Purpose Analytical Platform |
| Maximum Operating Pressure | 1300 bar |
| Temperature Control | Dual-Zone Capability (G7116A/B Modules) |
| Solvent Channels | 4 standard, up to 15 with optional Solvent Selection Valve |
| Column ID Reader | Optional |
| Column Internal Diameter Support | 8 mm max |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1290 Infinity III RID |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | Ultra-High Performance Liquid Chromatography (UHPLC) |
| Flow Cell Design | Ultra-Low Dispersion Micro-Flow Cell |
| Data Acquisition Rate | 148 Hz |
| Detection Principle | Differential Refractometry |
| Compliance | Designed for GLP/GMP environments with support for FDA 21 CFR Part 11–compliant software workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Sample Bottle Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 1300 bar |
| Injection Volume Range | Up to 1500 µL |
| Needle Wash Port | External surface rinse capability |
| Optional Integrated Column Oven | Temperature range 5–80 °C above ambient, accommodates two columns up to 30 cm length |
| Optional Integrated Sample Thermostat | Temperature control from 4–40 °C |
| Internal System Volume | Minimized design with bypass mode available |
| Overlapped Run/Injection Cycle | Enabled for throughput optimization |
| Programmable Sequence Logic | Supports pre-injection sample conditioning and advanced scheduling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III 2D-LC |
| Instrument Type | Multidimensional Liquid Chromatograph |
| Maximum Operating Pressure | 1300 bar |
| Application Scope | General-Purpose Analytical Platform |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 240 Hz |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Dynamic Range | > 2.5 AU |
| Wavelength Range | 190–950 nm |
| Wavelength Accuracy | ±0.1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with ±0.05 °C stability |
| Flow Cell Identification | RFID-enabled stainless steel or fused silica flow cells |
| Lamp Life Monitoring | Real-time EMF tracking with user-defined thresholds |
| Software Integration | Fully compatible with OpenLab CDS, MassHunter, and compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Wide Dynamic Range DAD |
| Instrument Type | Diode Array Detector (DAD) |
| Compatible System | Agilent InfinityLab LC Systems |
| Data Acquisition Rate | Up to 120 Hz (DAD FS variant) |
| Linear UV Dynamic Range Extension | 30× vs. conventional DAD |
| Temperature Control | Second-Generation Electronic Temperature Control (ETC) |
| Cell & Lamp Identification | RFID-enabled for audit-trail compliance |
| Flow Cell Pathlengths | Dual-path, optimized for high- and low-concentration analytes |
| Regulatory Support | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 218 |
| Instrument Type | UHPLC–Online SPE Coupled Purification System |
| Flow Rate Range | Up to 200 mL/min (configurable via interchangeable pump heads: 25, 100, or 200 mL/min) |
| Maximum Pressure Rating | 400 bar |
| Sample Injection Volume | 0.1–10 mL (manual or via Agilent 410 Autosampler) |
| Column Compatibility | Analytical to semi-preparative (up to 50 mm ID, including 1" and 2" i.d. columns) |
| Temperature Control | Ambient to 60 °C (optional column heater module) |
| Wavelength Range | 190–800 nm (dual-wavelength UV-Vis detection) |
| Data Acquisition Rate | Up to 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 240-MS |
| Instrument Type | Ion Trap Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Coupling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 240FS AA |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Sensitivity | Mark 7 Atomization System — Cu 5 mg/L typically yields >0.9 Abs |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 240Z AA |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | ≤0.2 nm |
| Repeatability (RSD) | <2% |
| Detection Limit (Cd) | ≤0.006 µg/L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 280FS AA |
| Instrument Type | Flame AAS |
| Monochromator Type | Fixed-grating with high-resolution etched grating |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Lamp Capacity | 8-lamp turret with automatic selection |
| Atomization System | Mark 7 Flame Burner Assembly |
| Sensitivity | >0.9 Abs for 5 mg/L Cu |
| Sample Volume per Analysis | 10 mL |
| Multi-element Throughput | Up to 10 elements per sample in <2 minutes |
| Calibration Automation | SIPS 10/20 Integrated Sample Introduction and Dilution System |
| Software Platform | SpectrAA Method Development Suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 280Z GFAA |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-Beam |
| Background Correction | Zeeman Effect |
| Atomizer | GTA 120 Zeeman Graphite Furnace |
| Light Source Configuration | Up to 8 Fixed-Lamp Positions |
| Detector | Photomultiplier Tube (PMT) |
| Calibration Method | Polynomial Interpolation |
| Software Platform | Windows-Based Worksheet Interface |
| Optional Hydride Generation Compatibility | VGA Adapter Available |
| Temperature Control Architecture | Isothermal Zone Graphite Furnace Design |
| Lamp Technology | UltrAA Hollow Cathode Lamps (AC-Modulated) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 3D CE |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Application | Organic Analysis |
| Detection | Diode Array Detector (DAD) |
| Capillary Temperature Control | Peltier + High-Velocity Air Cooling (10 m/s) |
| Injection | Self-Calibrating Pressure-Based Injection |
| Buffer Management | Offline Buffer Replenishment System |
| Optical Path Enhancement | Extended-Path Capillary Technology |
| Detector Compatibility | DAD, LIF, MS |
| CE-MS Coupling | Single-Supplier Integrated Interface |
| Fraction Collection | Yes |
| CE-CGC Compatibility | Yes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 4210 |
| Pricing | Available upon Request |
