| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BD6-70E |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Manometric (Pressure-Difference) Method |
| Temperature Range | 0–65 °C |
| BOD Measurement Range | 0–4000 mg/L |
| Accuracy | ±8% |
| Incubation Temperature Setting | 20 °C ±1 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| BOD Resolution | 0.01 mg/L |
| Test Duration | 1–30 days |
| Sample Capacity | 6 independent channels |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 450×320×500 mm (chamber), 275×185×75 mm (analyzer unit) |
| Internal Chamber Material | Mirror-finish stainless steel |
| Door Seal | Magnetic gasket |
| Control System | Microprocessor-based 30-segment programmable controller |
| Communication Options | RS485 (optional), USB (optional), Bluetooth data export (standard on BD6-70E) |
| Compliance | Designed for ASTM D5210, ISO 5815-1, and EPA Method 405.1 workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BD6-70 |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Mercury-Free Pressure-Difference Method (Dissolved Oxygen Depletion) |
| Incubation Temperature Range | 0–65 °C |
| BOD Measurement Range | 0–4000 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±8% |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Max. Sample Channels | 6 |
| Incubation Chamber Dimensions (W×D×H) | 450 × 320 × 500 mm |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BOD-100CP-VI |
| Instrument Type | Laboratory BOD Analyzer & Incubator |
| Principle | Manometric Pressure-Difference Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±8% |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Incubation Temperature Setpoint | 20 °C ±1 °C |
| Sample Capacity (Incubator) | 450 × 380 × 590 mm (W×D×H) |
| Independent Test Channels | Up to 6 |
| Data Storage Duration | 10 years |
| RS485 Interface | Yes |
| Built-in Power Outlet & 25 mm Test Port | Yes |
| Auto Temperature Compensation | Yes |
| Real-time Curve Logging & Export | Yes |
| Data Upload Capability | Yes |
| Battery Backup | Yes |
| Programmable Stages | 30-segment microprocessor controller |