| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT20-DZF / BAT50-DZF / BAT90-DZF / BAT210-DZF |
| Instrument Type | Vacuum Oven |
| Temperature Range | RT+10°C to 250°C |
| Temperature Fluctuation | ±1°C |
| Temperature Uniformity | ±3% (of setpoint) |
| Vacuum Degree | 133 Pa |
| External Dimensions (W×D×H mm) | 790×570×635 (BAT90-DZF) |
| Internal Chamber Dimensions (W×D×H mm) | 450×450×450 (BAT90-DZF) |
| Chamber Material | Mirror-Finish Stainless Steel |
| Controller | LCD Blue Backlit Microprocessor PID Controller with Real-Time Display |
| Timer Range | 0–9999 min or 0–999 h |
| Safety Features | Over-Temperature Alarm with Audible & Visual Alert |
| Optional Accessories | 5-inch Touchscreen Programmable Controller, USB Data Logging, RS485 Interface for PC Integration, Remote Monitoring via WeChat Mini-Program |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT50/100/150/250-JGF |
| Temperature Range | RT+10°C to 250°C |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Fluctuation | ±1°C |
| External Dimensions (W×D×H) | 555×495×820 mm (BAT50-JGF) |
| Internal Dimensions (W×D×H) | 350×370×395 mm (BAT50-JGF) |
| Interior Material | Mirror-Finish Stainless Steel |
| Control System | LCD Color Touch Controller with PID Algorithm |
| Sensor | PT100 Platinum Resistance Thermometer |
| Air Circulation | Horizontal Forced-Air Convection with Three-Speed Adjustable Centrifugal Blower |
| Safety Features | Independent Over-Temperature Cut-Off, Audible/Visual Alarm |
| Optional Accessories | USB Data Logging, RS485 PC Interface, 5-inch Programmable Touch Controller, Remote Monitoring via WeChat Mini Program |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-AR / BAT800-AR / BAT1000-AR / BAT1250-AR / BAT1700-AR / BAT2000-AR |
| Temperature Range | 5–45°C (dark), 10–45°C (with lighting) |
| Humidity Range | 40–80% RH (light on), 50–90% RH (light off) @ 15–45°C |
| Temp. Uniformity | ±0.5°C (per shelf level) |
| Temp. Control Accuracy | ±0.1°C |
| Humidity Control Accuracy | ±1% RH |
| Humidity Fluctuation | ±3% RH |
| Photosynthetic Photon Flux Density (PPFD) | 0–400 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp) |
| Air Exchange Rate | up to 0.57 m³/min |
| Programmable Stages | 24-segment time-based scheduling with real-time Beijing time sync |
| Control System | BAT200PG OS, 7-inch color touchscreen interface |
| Cooling Method | Hot-gas bypass refrigeration |
| Defrost Mode | Solenoid-valve controlled automatic defrost |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |
| Data Logging | Internal storage for ≥5 years of operational records |
| User Access Levels | Four-tier password management (Factory Admin, User Admin, Operator Template, Engineer Template) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-PG / BAT800-PG / BAT1000-PG / BAT1250-PG / BAT1700-PG / BAT2000-PG |
| Temperature Range | 5–45°C (dark), 10–45°C (with lighting) |
| Humidity Range | 40–80% RH (light on), 50–90% RH (light off) @ 15–45°C |
| Temp Uniformity | ±0.5°C (per shelf) |
| Temp Accuracy | ±0.1°C |
| Humidity Accuracy | ±1% RH |
| Humidity Fluctuation | ±3% RH (per shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–600 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp) |
| Optional Upgrades | CO₂ control module, multi-spectral LED lighting (up to 800 µmol/m²/s), closed-loop dimming system, remote monitoring interface |
| Brand | Boante |
|---|---|
| Model Series | BAT700-FS, BAT800-FS, BAT1000-FS, BAT1100-FS, BAT1200-FS |
| Construction Material | 0.6–1.0 mm stainless steel (AISI 304 equivalent) |
| Layer Count | 7–12 |
| Dimensions (W×D×H) | 140 × 145 × 400 mm to 140 × 145 × 700 mm |
| Compatible Storage Box Size | 133 × 133 × 54 mm (standard) |
| Capacity per Layer | 7–12 boxes (81-well paper or 100-well plastic cryoboxes) |
| Surface Finish | Smooth deburred edges, electropolished weld zones |
| Compliance | Designed for long-term operation at –80 °C and –196 °C (liquid nitrogen vapor phase) |
| Warranty | 12-month limited warranty covering material and workmanship defects under normal cryogenic use |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-1G |
| Instrument Type | Planetary Ball Mill |
| Maximum Feed Size | ≤10 mm (soil), ≤3 mm (other materials) |
| Final Particle Size | down to 0.1 µm |
| Minimum Sample Volume | 100 mL per jar |
| Maximum Capacity | 4 × 1000 mL |
| Main Disc Speed | 5–400 rpm |
| Grinding Jar Speed | 10–800 rpm |
| Display | 5-inch OLED touchscreen |
| Programmable Cycles | 30-segment multi-step programs |
| Drive Motor | Imported German 300 W energy-efficient servo motor |
| Lid Operation | Electric actuation |
| Bidirectional Rotation (clockwise/counter-clockwise) | Yes |
| Emergency Stop | Yes |
| Continuous Operation Time | 1–9999 min |
| Pause Duration | 1–999 min |
| Compatible Jar Volumes | 100–1500 mL (standard: 100–1000 mL) |
| Jar Materials | Stainless steel, agate, zirconia, alumina, tungsten carbide, polyurethane |
| Grinding Media Materials | Stainless steel, agate, zirconia, alumina, nylon, PTFE |
| Media Diameter | 3 / 5 / 10 / 15 / 20 mm |
| Media Mass per Jar | 200–1000 g |
| Grinding Modes | Dry grinding and wet grinding |
| Cryogenic Grinding Support | Optional (with external cooling system) |
| Inert Atmosphere Processing | Yes (via gas inlet port) |
| Dimensions (W×D×H) | 600 × 430 × 430 mm |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-48GLS |
| Instrument Type | Cryogenic Ball Mill |
| Sample Capacity | 48 × 2 mL tubes (standard) |
| Display | Touchscreen interface |
| Programmable Segments | Optional |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s – 99 min |
| Final Particle Size | ≤5 µm |
| Grinding Media Diameter | 0.1–30 mm |
| Grinding Media Materials | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Acceleration | Reaches maximum speed within 2 s |
| Noise Level | <55 dB(A) |
| Grinding Method | Vertical high-energy bead milling (dry, wet, or cryogenic) |
| Cryogenic Temperature Range | 0 °C to –50 °C (adjustable) |
| Dimensions (W×D×H) | 700 × 400 × 500 mm |
| Weight | 50 kg |
| Safety Features | Interlocked chamber door, automatic centering clamping system, fully enclosed sample tubes during operation |
| Construction | Full-metal frame |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-48LS |
| Instrument Type | Bead Mill Grinder |
| Sample Capacity | 24 × 2 mL (standard), optional: 12 × 5 mL, 4 × 10 mL, 2 × 25 mL |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s–99 min (programmable) |
| Final Particle Size | ≤5 µm |
| Grinding Media Diameter | 0.1–30 mm |
| Grinding Media Materials | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Acceleration | Reaches max speed in ≤2 s |
| Noise Level | <55 dB(A) |
| Grinding Method | Vertical high-energy bead milling |
| Operation Modes | Dry grinding, wet grinding, cryogenic grinding (with liquid nitrogen adapters) |
| Display | Touchscreen interface with multi-step program control |
| Dimensions (W×D×H) | 260 × 380 × 500 mm |
| Weight | 25 kg |
| Safety Features | Interlocked safety lid, auto-centering clamping system, fully enclosed sample tubes during operation |
| Construction | All-metal housing, PTFE- and zirconia-compatible grinding kits |
| Brand | Boante |
|---|---|
| Model | Grind-48P |
| Origin | Hubei, China |
| Instrument Type | Bead Mill Grinder |
| Sample Capacity | Up to 48 × 2 mL tubes (configurable with 12/24/48-position cryo-adapters) |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s – 99 min (programmable) |
| Final Particle Size | ≤5 µm |
| Grinding Media Diameter | 0.1–30 mm |
| Grinding Media Materials | Stainless steel, chromium steel, zirconia, tungsten carbide, quartz |
| Acceleration | Reaches maximum speed within 2 s |
| Noise Level | <55 dB(A) |
| Dimensions (W×D×H) | 260 × 380 × 500 mm |
| Weight | 25 kg |
| Drive Mechanism | Vertical dual-platform eccentric oscillation with 3D motion trajectory |
| Safety Features | Interlocked chamber lid, auto-centering clamping system, fully enclosed sample tubes |
| Display | Touchscreen interface with multi-step program storage |
| Grinding Modes | Dry grinding, wet grinding, cryogenic grinding (LN₂-compatible) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-4GLD |
| Instrument Type | Planetary Ball Mill |
| Maximum Sample Volume | 4 × 1000 mL |
| Minimum Final Particle Size | 0.1 µm |
| Feed Size | ≤10 mm (soil), ≤3 mm (other materials) |
| Main Disc Speed | 50–400 rpm |
| Grinding Jar Speed | 100–800 rpm |
| Transmission Ratio (Main Disc | Jar): 1 : −2 |
| Direction Control | Forward/Reverse |
| Emergency Stop | Yes |
| Continuous Operation Time Range | 1–9999 min |
| Pause Duration Range | 1–9999 min |
| Programmable Steps | 30-segment bidirectional sequence |
| Grinding Modes | Dry, Wet, Cryogenic (optional liquid nitrogen jacket or chiller integration) |
| Inert Atmosphere Compatibility | Yes (via sealed jar with gas inlet/outlet) |
| Compliance | CE |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-64YS |
| Instrument Type | High-Throughput Ball Mill |
| Sample Capacity | 48 × 2 mL tubes (standard) |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s–99 min (programmable) |
| Final Particle Size | ≤5 µm |
| Grinding Media Diameter | 0.1–30 mm |
| Grinding Media Materials | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Acceleration | Achieves maximum speed within 2 s |
| Noise Level | <55 dB(A) |
| Drive Principle | 3D orbital motion (vertical + horizontal bidirectional oscillation) with patented anti-vibration engineering |
| Cooling Compatibility | Liquid nitrogen adapters (12-position and 24-position) included |
| Safety Features | Interlocked safety lid, automatic centering clamping system, fully enclosed sample tubes during operation |
| Construction | All-metal housing (stainless steel frame + reinforced aluminum alloy chassis) |
| Dimensions (W×D×H) | 400 × 400 × 480 mm |
| Weight | 25 kg |
| Display | Capacitive touchscreen interface with multi-step program storage |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | Grind-6P |
| Instrument Type | Bead Mill Grinder |
| Sample Capacity | Standard 6 × 5 mL alloy adapter |
| Display | Touchscreen interface |
| Programmable Stages | Multi-segment programming available |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s – 99 min (adjustable) |
| Feed Size | Adjustable per adapter |
| Final Particle Size | ≤ 5 µm |
| Number of Grinding Platforms | ≥ 2 |
| Grinding Ball Diameter | 0.1–30 mm |
| Grinding Ball Materials | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Acceleration | Reaches maximum speed within 2 s |
| Noise Level | < 55 dB(A) |
| Grinding Method | Vertical bead-milling |
| Dimensions (W×D×H) | 220 × 300 × 400 mm |
| Weight | 14 kg |
| Safety Features | Interlocked safety lid, auto-centering clamping mechanism, fully enclosed sample tubes, all-metal housing |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Cryogenic Ball Mill |
| Model | Grind-96P |
| Sample Capacity | 96 × 2 mL PE or alloy rack (optional: 24×2 mL, 48×2 mL, 12×5 mL, 4×10 mL, 4×25 mL, 2×50 mL) |
| Display | 5-inch OLED touchscreen |
| Programmable Methods | ≥20 preset protocols (e.g., heart, spleen, lung, kidney, bone, hair) |
| Multi-Step Grinding | Yes, cyclic execution across up to 5 parameter sets |
| Frequency Range | 0–70 Hz |
| Grinding Time | 0 s–99 min |
| Cryogenic Range | +20 °C to –50 °C |
| Cooling Rate | ~40 min from +20 °C to –50 °C |
| Grinding Media Diameter | 0.1–30 mm |
| Vertical Stroke | 34 mm |
| Acceleration | ≤2 s to max speed |
| Final Particle Size | ≤5 µm |
| Noise Level | <55 dB(A) |
| Grinding Mechanism | Vertical bead-based impact and shear |
| Cooling Method | Integrated cryo-cooling system with programmable temperature control |
| Construction | Full metal housing with electromagnetic safety lock, acoustic insulation, and auto-centering clamping system |
| Dimensions (W×D×H) | 450×450×720 mm |
| Weight | 55 kg |
| Brand | Boante |
|---|---|
| Model | Grind-96S |
| Instrument Type | Ball Mill Grinder |
| Sample Capacity | Up to 96 × 2 mL tubes (with interchangeable adapters) |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s–99 min (programmable) |
| Final Particle Size | ≤5 µm |
| Grinding Media Diameter | 0.1–30 mm |
| Grinding Media Materials | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Acceleration | Achieves target frequency within 2 s |
| Noise Level | <55 dB(A) |
| Dimensions | 340 × 380 × 600 mm |
| Weight | 35 kg |
| Safety Features | Interlocked chamber door, automatic centering clamping, fully enclosed tube system |
| Grinding Modes | Dry grinding, wet grinding, cryogenic grinding (with liquid nitrogen adapters) |
| Display | Touchscreen interface with multi-step program control |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Boante |
|---|---|
| Model | Grind-LT48P |
| Type | Cryogenic Ball Mill Grinder |
| Sample Capacity | 48 × 2 mL tubes (standard) |
| Cooling Range | −50 °C to 20 °C |
| Grinding Frequency | 0–70 Hz |
| Grinding Time | 0 s–99 min |
| Final Particle Size | ≤5 µm |
| Noise Level | <55 dB(A) |
| Dimensions | 450 × 450 × 720 mm |
| Weight | 55 kg |
| Display | 5-inch OLED touchscreen |
| Pre-stored Protocols | ≥20 |
| Multi-step Programming | Yes |
| Grinding Motion | Vertical reciprocating + 3D orbital motion |
| Grinding Media Diameter | 0.1–30 mm |
| Stroke Length | 34 mm (vertical) |
| Refrigeration Rate | 20 °C → −50 °C in ~40 min |
| Safety | Electromagnetic lid lock, auto-centering clamping, fully enclosed sample tubes |
| Compliance | Designed for GLP-compliant labs |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | Upon Request |
| Photosynthetic Photon Flux Density (PPFD) at 150 cm | 500 μmol/m²/s |
| Spectral Range | 400–780 nm (continuous) |
| LED Channel Ratio (Red | Blue:White:Far-Red): 4:2:2:2 |
| Spectral Stability | ≤ ±5% fluctuation per channel |
| Rated LED Lifetime | ≥ 50,000 hours |
| Thermal Management | Automatic active cooling system |
| Brand | Boante |
|---|---|
| Model | Mini-4plus |
| Instrument Type | Benchtop Bead Mill Grinder |
| Construction | All-Metal Housing |
| Sample Capacity | 4 or 6 Tubes Simultaneously |
| Grinding Motion | 3D “Figure-8” Orbital Motion (Vortexing + Oscillation + Suction) |
| Max Speed | 6000 rpm |
| Acceleration Time | ≤2 s to Max Speed |
| Grinding Time Range | 0–9999 s (Programmable) |
| Final Particle Size | ≤5 µm |
| Noise Level | <55 dB(A) |
| Display | LCD Interface |
| Dimensions (W×D×H) | 210 × 185 × 220 mm |
| Weight | 4.8 kg |
| Power Consumption | 35 W |
| Safety | Interlocked Lid Sensor, Sealed Tube Processing, Zero Cross-Contamination Design |
| Compliance | Designed for GLP-compliant sample prep workflows |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| CO₂ Control Range (M-type) | Ambient +100 ppm to 2000 ppm |
| CO₂ Control Range (MD-type) | 180 ppm to 2000 ppm (customizable) |
| CO₂ Detection Accuracy | ±1 ppm |
| CO₂ Control Accuracy | ±3% of setpoint |
| CO₂ Sensor Technology | NDIR with Vaisala CARBOCAP® module |
| Response Time (0→2000 ppm) | ≤5 s |
| Concentration Step Response Time (100 ppm step) | 15 s |
| CO₂ Output Channels | 2 or 3 |
| Air Output Channels | 2 or 3 |
| Gas Flow Range (CO₂) | 0.16–1.6 L/min (optional high-flow: 0.4–6 L/min) |
| Pump Type | Oil-free DC diaphragm pump |
| Flow Stability | ±0.3% FS |
| Noise Level | ≤42 dB(A) |
| Chamber Material | Stainless steel with corrosion-resistant coating |
| Calibration Interval | 12 months |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 10–30 °C |
| Compatible Media | Freshwater, synthetic seawater, low-salinity and high-salinity seawater (≤45‰) |
| Control Interface | 7-inch capacitive touchscreen |
| Control Algorithm | Adaptive PID + fuzzy logic |
| Data Logging | Real-time timestamped gradient tracking with power-loss recovery |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| CO₂ Control Range | Ambient +100 ppm to 2000 ppm |
| O₂ Control Range (MGAR-G) | 0–21% vol |
| (MGAR-D) | 21–100% vol |
| CO₂ Detection Accuracy | ±1 ppm |
| O₂ Detection Accuracy | ±0.1% vol |
| CO₂ Control Precision | ±3% of setpoint |
| O₂ Control Precision | ±5% of setpoint |
| CO₂ Sensor | NDIR with Vaisala CARBOCAP® module |
| O₂ Sensor | Electrochemical cell (RAE Systems) |
| N₂ Input Max Flow | 1.6 L/min |
| CO₂ Output Flow Range | 0.16–1.6 L/min (customizable up to 6 L/min) |
| O₂/Air Output Flow | Adjustable via calibrated rotameter |
| Mixing Chamber Pressure Range | −10 to +10 kPa |
| CO₂ Response Time (0→2000 ppm) | ≤5 s |
| O₂ Response Time (0→21%) | ≤15 s |
| CO₂ Regulation Response Time (100 ppm step) | 15 s |
| O₂ Regulation Response Time (1% step) | 15 s |
| Display | 7-inch capacitive touchscreen |
| Control Algorithm | PID + adaptive fuzzy logic |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 200 W |
| Operating Temperature | 10–30 °C |
| Humidity Range | 30–80% RH (non-condensing) |
| Enclosure Material | Stainless steel with corrosion-resistant white epoxy coating |
| Calibration Interval | 12 months |
| Compatible Media | Freshwater, synthetic seawater, low-salinity and high-salinity seawater (≤45‰) |
| Brand | Boante |
|---|---|
| Model Range | SC801M, SC802M, SC803M, SC804M, SC806M, SC801MD, SC802MD, SC803MD, SC804MD, SC806MD |
| Control Interface | 7-inch TFT touch screen |
| CO₂ Concentration Range (M) | Ambient +100 ppm to 2000 ppm |
| CO₂ Concentration Range (MD) | 180 ppm to 2000 ppm (customizable) |
| Detection Accuracy | ±1 ppm |
| Control Accuracy | ±3% of setpoint |
| Sensor Type | NDIR infrared with Vaisala CARBOCAP® module |
| Response Time (Detection) | ≤5 s (0→2000 ppm step) |
| Concentration Adjustment Response Time | 15 s (100 ppm step) |
| CO₂ Flow Rate Range | 0.16–1.6 L/min (standard) |
| optional high-flow | 0.4–6 L/min |
| Air Flow Regulation | Yes |
| Number of CO₂ Output Channels | 1, 2, 3, 4, or 6 |
| Air Output Channels | 1 |
| Pump Type | Oil-free DC diaphragm pump |
| Flow Stability | ±0.3% FS |
| Noise Level | ≤42 dB(A) |
| Enclosure Material | Stainless steel with corrosion-resistant white coating |
| Operating Temperature | 10–30 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 100–220 W (model-dependent) |
| Calibration Interval | 12 months |
| Water Compatibility | Freshwater, synthetic media, low-salinity seawater, high-salinity seawater (≤45‰) |
| Control Algorithm | Adaptive PID + fuzzy logic |
| Compliance | Designed for GLP-aligned environmental simulation workflows |
| Brand | Bode |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | BLC-12 |
| Pricing | Available Upon Request |
| Brand | BEQ |
|---|---|
| Origin | Anhui, China |
| Model | BOF-4-300-11-GB |
| Max Temperature | 600°C |
| Temperature Control Accuracy | ±1°C |
| Max Power | 15 kW |
| Heating Rate to Max Temp | ≤10°C/min |
| Heating Method | Resistance Wire Heating |
| Control System | Fuzzy PID + Auto-Tuning, 30-Stage Programmable Logic Controller with Over-Temperature and Thermocouple Failure Alarms |
| Tube Dimensions | Φ300 mm × 3000 mm |
| Glovebox Integration | Dual Front/Back Integrated Inert Atmosphere Enclosures (O₂ < 1 ppm, H₂O < 1 ppm) |
| Sample Loading Ports | 8 Access Ports (4 per glovebox) |
| Brand | BOLA |
|---|---|
| Origin | Germany |
| Construction Materials | PP, PTFE, Hastelloy C-276 |
| Operating Temperature Range | +5 °C to +60 °C |
| Chemical Resistance Rating | Excellent (++) |
| Power Source | Two 1.5 V AA batteries |
| Tubing ID | 25 mm |
| Tubing Length Options | 400 mm and 600 mm |
| Maximum Flow Rate | 6 L/min |
| Compatible Vessel Neck Sizes | NS 29 and GL 45 |
| Application Scope | Low-viscosity corrosive liquids (e.g., dilute acids, caustic solutions, solvents) |
| Brand | BOLA |
|---|---|
| Origin | Germany |
| Vessel Material | PTFE / PFA Liner |
| Operating Temperature Range | –200 °C to +250 °C |
| Maximum Working Pressure | Low-Pressure (≤ 1 bar gauge) |
| Vacuum Capability | ≤ 10 mbar (absolute) |
| Nominal Capacity | 600 mL |
| Flange Standard | NW100 / NW150 |
| Compliance | Designed for GLP-compliant synthesis and distillation workflows under ISO 9001-manufactured conditions |
| Brand | BOLA |
|---|---|
| Origin | Germany |
| Construction Materials | Polypropylene (PP) and Polytetrafluoroethylene (PTFE) |
| Operating Temperature Range | −10 °C to +90 °C |
| Chemical Resistance | Excellent |
| Maximum Suction Height | 4.5 m |
| Sample Volume per Stroke | 50 mL |
| Bottle Thread Standard | GL18 (pump head), GL45 (bottle interface) |
| Compatible Bottle Capacity | 100–2000 mL |
| Suitability | Low-volatility, high-viscosity, and highly corrosive liquids |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BORA Series (N2-BORA-500 / N2-BORA-1300) |
| Purity | 99.999%+ (N2-BORA-500) or 99.995% (N2-BORA-1300) |
| Residual O₂ | <10 ppm (N2-BORA-500) or <50 ppm (N2-BORA-1300) |
| Flow Rate | 500 mL/min or 1300 mL/min |
| Integrated Oil-Free Compressor | Yes |
| Compliance | ISO 9001 certified |
| Maintenance Interval | Filter & Silencer replacement every 4,000 operating hours |
| Operating Pressure | Low-pressure ambient system (no high-pressure cylinders or cryogenic storage) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGG-79 |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | RT+20°C to 500°C |
| Temperature Uniformity | ±2°C |
| External Dimensions (W×D×H) | 770 × 580 × 800 mm |
| Internal Chamber Dimensions (W×D×H) | 400 × 400 × 450 mm |
| Chamber Volume | 70 L |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Dual-Stage Air Mixing |
| Control System | Microprocessor-Based PID Controller with LCD Display, Timer, Power Limiting & Auto-Tuning |
| Temperature Resolution | 0.1°C |
| Input Voltage | 220 V AC |
| Rated Power | 3400 W |
| Standard Shelves | 2 Adjustable Stainless Steel Trays |
| Door Seal | Dual-Layer Ceramic Fiber Gasket |
| Door Mechanism | Dual Cam-Lock Hinges |
| Chamber Corner Design | Radius-Rounded Internal Corners |
| Safety Features | Power Recovery Function, Over-Temperature Protection, Thermal Cut-Out |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGH-130S |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5 to 300 °C |
| Temperature Fluctuation | ±0.3 °C |
| External Dimensions (L×W×H, mm) | 735×658×757 |
| Internal Dimensions (L×W×H, mm) | 570×400×570 |
| Temperature Resolution | 0.1 °C |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Circulation |
| Temperature Uniformity | ±1.9 °C |
| Chamber Volume | 129 L |
| Power Rating | 1.8 kW |
| Standard Shelves | 2 (max. 7) |
| Shelf Load Capacity | 25 kg per shelf |
| Stacking Support | Yes (up to 2 units) |
| Ramp/Soak Programming | 30 segments × 99 cycles |
| Ventilation Control | Motorized 10-step adjustable exhaust damper |
| Fan Speed Control | 6-step variable-speed blower |
| Data Storage Capacity | 4 million records |
| Interface Ports | Dual RS-485, 1×USB |
| Optional | Inlet/Exhaust HEPA Filters |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +10°C to 250°C |
| Temperature Uniformity | ±1°C |
| Chamber Dimensions (W×D×H) | 450 × 500 × 450 mm |
| External Dimensions (W×D×H) | 620 × 640 × 1165 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Bottom-mounted Heated Shelf System |
| Ultimate Vacuum | 133 Pa |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 1400 W |
| Shelf Quantity | 2 (Independently Controlled) |
| Timer Range | 0–9999 min |
| Surface Temperature (at max operating temp) | ≤65°C |
| Vacuum Pump Speed | 2 L/s |
| Compliance | GB/T 29251–2012 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGM-90FE |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.24 MPa |
| Chamber Dimensions | Ø380 mm × 735 mm |
| External Dimensions | 605 mm × 513 mm × 1040 mm |
| Chamber Volume | 90 L |
| Design Pressure | 0.39 MPa |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤1 °C |
| Temperature Fluctuation | ±1 °C |
| Sterilization Time Range | 0–240 min |
| Melting/Insulation Time Range | 0–6000 min |
| Power Input | 3.6 kW |
| Operating Ambient | 5–40 °C, 20–80% RH |