| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Models | BGZ-30 / BGZ-70 / BGZ-140 / BGZ-240 / BGZ-76 / BGZ-146 / BGZ-246 |
| Instrument Type | General-Purpose Forced-Air Oven |
| Temperature Range | Ambient +5°C to 250°C (up to 300°C for high-temp models) |
| Temperature Uniformity | ±1°C |
| Exterior Dimensions | 640×485×545 mm (varies by model) |
| Interior Chamber Dimensions | 350×350×350 mm (varies by model) |
| Interior Material | Mirror-Finish Stainless Steel |
| Heating Method | Forced-Air Convection with Adjustable Fan Speed |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | General-Purpose Forced-Air Drying Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±1°C (at 105°C) |
| Control Resolution | 0.1°C |
| Internal Chamber Dimensions (W×D×H) | 450×380×450 mm |
| External Dimensions (W×D×H) | 740×605×605 mm |
| Heating Method | Circulating Hot Air with 6-Stage Adjustable Fan Speed |
| Inner Chamber Material | Mirror-Finish Stainless Steel |
| Insulation | High-Density Mineral Wool |
| Power Supply | AC 220V ±10%, 50Hz ±2% |
| Input Power | 1350 W |
| Timer Range | 0–9999 min/h (switchable) |
| Programmable Control | 10 segments × 100 cycles |
| Data Interface | RS-485 |
| Compliance | GB/T 30435-2013 |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-30 |
| Temperature Range | RT+5°C to 250°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±1°C at 105°C |
| Control Resolution | 0.1°C |
| Internal Chamber Dimensions (L×W×H) | 350×330×350 mm |
| External Dimensions (L×W×H) | 640×555×505 mm |
| Heating Method | Forced-air convection with adjustable fan speed (6-step) |
| Insulation | High-efficiency mineral fiber |
| Inner Chamber Material | Mirror-finish stainless steel (AISI 304) |
| Power Supply | AC 220V±10%, 50Hz±2% (BGZ-30–BGZ-240) |
| Input Power | 950 W (BGZ-30) to 3100 W (BGZ-420) |
| Timer Range | 0–9999 min/h (selectable) |
| Programmable Control | 10 segments × 100 cycles |
| Communication Interface | RS-485 |
| Compliance | GB/T 30435–2013 |
| Key | Brand: Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-76 |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±0.8°C at 105°C |
| Temperature Resolution | 0.1°C |
| Interior Dimensions (L×W×H) | 410×350×450 mm |
| Exterior Dimensions (L×W×H) | 555×566×722 mm |
| Heating Method | Forced-air convection with adjustable fan speed (6-speed) |
| Interior Material | Mirror-finish stainless steel |
| Insulation | High-efficiency mineral fiber |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 1550 W |
| Timer Range | 0–9999 min/h (switchable) |
| Programmable Control | 10 segments × 100 cycles |
| RS-485 Interface | Standard |
| Compliance | GB/T 30435–2013 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-140 |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±1°C (at 105°C) |
| Temperature Resolution | 0.1°C |
| Internal Chamber Dimensions (W×D×H) | 550×470×550 mm |
| External Dimensions (W×D×H) | 840×695×705 mm |
| Heating Method | Forced-air convection with adjustable fan speed (6-speed) |
| Inner Chamber Material | Mirror-finish stainless steel (SUS304) |
| Insulation | High-density mineral fiber |
| Control System | PMMA II touchscreen interface with color LCD |
| Programmable Stages | Up to 10 segments × 100 cycles |
| Timer Range | 0–9999 min/h (selectable) |
| Delayed Start | Yes |
| Power Input | AC 220V ±10%, 50Hz ±2% |
| Rated Power | 1750 W |
| Standard Compliance | GB/T 30435–2013 |
| Interface | RS-485 for PC connectivity |
| Data Integrity Features | Power-loss recovery, audit-ready operation log |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-140 |
| Price Range | USD 280–700 (FOB) |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% (at setpoint) |
| External Dimensions (W×D×H) | 840 × 695 × 705 mm |
| Internal Chamber Dimensions (W×D×H) | 550 × 470 × 550 mm |
| Interior Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-146 / BGZ-246 |
| Display Type | LCD Upgrade Version |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Temperature Range | Ambient +5 °C to 300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Input Power | 2000 W |
| Interior Dimensions (W×D×H) | 550 × 500 × 550 mm |
| Exterior Dimensions (W×D×H) | 840 × 625 × 780 mm |
| Shelving | 3 adjustable stainless-steel shelves |
| Timer Range | 0–99 h 60 min |
| Interface | RS-485 for PC/data logger connectivity |
| Construction | Cold-rolled steel exterior with eco-friendly metallic paint |
| Air Circulation | Precision-engineered forced-air system with imported motor and impeller |
| Safety Features | Power-loss parameter retention and auto-recovery, over-temperature alarm, real-time monitoring capability |
| Key | Brand: BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-146 |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±0.8°C at 105°C |
| Temperature Resolution | 0.1°C |
| Internal Chamber Dimensions (W×D×H) | 570×400×570 mm |
| External Dimensions (W×D×H) | 715×616×842 mm |
| Heating Method | Forced-air convection with adjustable fan speed (6-speed) |
| Chamber Material | Mirror-finish stainless steel (AISI 304) |
| Insulation | High-density mineral fiber |
| Control System | PMMA II touchscreen interface with programmable logic |
| Programming Capacity | 10 segments × 100 cycles |
| Timer Range | 0–9999 min/h (configurable) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 2150 W |
| Operating Ambient | 5–40°C |
| Compliance | GB/T 30435–2013 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| External Dimensions (W×D×H) | 715 × 616 × 842 mm |
| Internal Chamber Dimensions (W×D×H) | 570 × 400 × 570 mm |
| Temperature Resolution | 0.1°C |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Control System | PMMA II Touchscreen Interface with Programmable Logic |
| Programming Capacity | 10 segments × 100 cycles |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 2150 W |
| Chamber Volume | 129 L |
| Standard Shelves | 2 pcs (max. 7 pcs), Load Capacity per Shelf: 15 kg |
| Communication Interface | RS-485 (standard) |
| Safety Features | Over-Temperature Alarm, Auto-Recovery after Power Interruption, Dual-Stage Door Locking Mechanism |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-240 |
| Instrument Type | General-Purpose Forced-Air Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±1°C (at 105°C) |
| Temperature Resolution | 0.1°C |
| Internal Chamber Dimensions (L×W×H) | 600 × 520 × 750 mm |
| External Dimensions (L×W×H) | 890 × 745 × 905 mm |
| Heating Method | Forced Convection with Adjustable Airflow |
| Inner Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 2150 W |
| Timer Range | 0–9999 min/h (selectable units) |
| Programmable Control | 10 segments × 100 cycles |
| Fan Speed Control | 6-step adjustable |
| Communication Interface | RS-485 |
| Compliance | GB/T 30435–2013 |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-240 |
| Price Range | USD 700–1,150 (FOB) |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% (at setpoint) |
| External Dimensions (W×D×H) | 890 × 745 × 905 mm |
| Internal Chamber Dimensions (W×D×H) | 600 × 520 × 750 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Control Resolution | 0.1°C |
| Temperature Stability | ±1°C at 100°C |
| Rated Power | 2150 W |
| Chamber Volume | 234 L |
| Standard Shelves | 3 pcs (max. 10 pcs) |
| Shelf Load Capacity | 15 kg per shelf |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Stages | 10 segments × 100 cycles |
| Interface | RS-485 for PC connectivity |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Recovery Function | Auto-restart with parameter retention after power interruption |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-246 |
| Type | High-Temperature Forced-Air Oven |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| Temperature Fluctuation | ±0.8°C at 105°C |
| Temperature Resolution | 0.1°C |
| Internal Chamber Dimensions (L×W×H) | 630×530×630 mm |
| External Dimensions (L×W×H) | 775×746×902 mm |
| Heating Method | Forced-air convection with adjustable fan speed (6-speed) |
| Chamber Material | Mirror-finish stainless steel (SUS304) |
| Insulation | High-density mineral fiber |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 2750 W |
| Programming Capacity | 10 segments × 100 cycles |
| Timer Range | 0–9999 min/h (switchable) |
| 预约 Function | Yes (up to 9999 min) |
| Communication Interface | RS-485 (standard) |
| Compliance | GB/T 30435–2013 |
| Operating Ambient | 0–40°C |
| Shelf Load Capacity | 15 kg per shelf |
| Standard Shelves | 3 (max. 8) |
| Preheating Air Chamber | Integrated |
| Door Seal | Dual-stage rotary locking with high-compression silicone gasket |
| Safety Features | Over-temperature alarm, auto-restart after power recovery, audit-ready event logging |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-246 |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| External Dimensions (W×D×H) | 775 × 764 × 902 mm |
| Internal Chamber Dimensions (W×D×H) | 630 × 530 × 630 mm |
| Interior Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.8°C at 105°C |
| Rated Power | 2750 W |
| Chamber Volume | 210 L |
| Standard Shelves | 3 pcs (max. 8 pcs) |
| Shelf Load Capacity | 15 kg per shelf |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Control | 10 segments × 100 cycles |
| Interface | RS-485 standard port |
| Power Recovery Function | Yes |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BGZ-30 |
| Instrument Type | General-Purpose Forced-Air Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±1°C (at setpoint) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.5°C (at 100°C) |
| External Dimensions | 640 × 485 × 525 mm |
| Internal Chamber Dimensions | 350 × 350 × 350 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Convection with Adjustable Fan Speed |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 550 W |
| Shelf Capacity | 2 Adjustable Stainless Steel Shelves |
| Timer Range | 0–99 h 60 min |
| Programmable Profile | 10 segments × 100 cycles |
| Communication Interface | RS-485 (Modbus RTU protocol) |
| Data Retention | Power-Fail Recovery with Non-Volatile Parameter Memory |
| Optional Accessories | Thermal Printer (curve logging), GPRS Remote Alert Module, PC-Based Supervisory Software |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-306 |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| External Dimensions | 865 × 764 × 1017 mm |
| Internal Chamber Dimensions | 720 × 530 × 745 mm |
| Interior Material | Mirror-Finish Stainless Steel |
| Heating Method | Forced-Air Circulation (PMMA II Control System) |
| Temperature Resolution | 0.1°C |
| Temperature Stability | ±0.8°C at 105°C |
| Rated Power | 2750 W |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Stages | 10 segments × 100 cycles |
| Chamber Volume | 284 L |
| Standard Shelves | 3 (max. 10) |
| Shelf Load Capacity | 15 kg per shelf |
| Interface | RS-485 |
| Power Recovery Function | Yes |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-420 |
| Instrument Type | High-Temperature Forced-Air Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% (at setpoint) |
| External Dimensions | 780 × 710 × 1745 mm |
| Internal Chamber Dimensions | 600 × 585 × 1300 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Convection with Adjustable Fan Speed |
| Control Resolution | 0.1°C |
| Temperature Fluctuation | ±1°C (at 100°C) |
| Rated Power | 3100 W |
| Volume | 456 L |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Stages | 10 segments × 100 cycles |
| Standard Shelves | 3 (up to 6 configurable) |
| Shelf Load Capacity | 15 kg per shelf |
| Interface | RS-485 |
| Power Supply | AC 380 V / 50 Hz |
| Data Retention | Power-Fail Memory with Auto-Restore Function |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-456 |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient + 5°C to 300°C |
| Temperature Uniformity | ±2% |
| External Dimensions (W×D×H) | 774 × 845 × 1704 mm |
| Internal Chamber Dimensions (W×D×H) | 600 × 580 × 1300 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.8°C at 105°C |
| Rated Power | 3500 W |
| Chamber Volume | 452 L |
| Standard Shelves | 4 pcs (max. 18 pcs) |
| Shelf Load Capacity | 15 kg per shelf |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Control | 10 segments × 100 cycles |
| Interface | RS-485 (standard) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Recovery Function | Power-Failure Resume & System Auto-Restart |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-70 |
| Instrument Type | High-Temperature Forced-Air Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% (at setpoint) |
| External Dimensions (W×D×H) | 740 × 605 × 605 mm |
| Internal Chamber Dimensions (W×D×H) | 450 × 380 × 450 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Control Resolution | 0.1°C |
| Temperature Fluctuation | ±1°C at 105°C |
| Chamber Volume | 76 L |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 1350 W |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Stages | 10 segments × 100 cycles |
| Standard Shelving | 2 stainless steel shelves (max. 5), load capacity 15 kg per shelf |
| Interface | RS-485 for PC connectivity |
| Compliance Features | Power-loss recovery, over-temperature alarm, door-seal integrity verification via dual-stage rotary latch |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-76 |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Uniformity | ±2% |
| External Dimensions (W×D×H) | 555×566×722 mm |
| Internal Chamber Dimensions (W×D×H) | 410×350×450 mm |
| Interior Material | Mirror-Finish Stainless Steel |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-1CD / BJ-2CD |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Adjustable Air Velocity Range | 0.1–0.6 m/s |
| Noise Level | ≤62 dB(A) |
| Illuminance | ≥300 lx |
| Vibration Half-Peak Amplitude | ≤3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.2 kW (BJ-1CD) / 0.37 kW (BJ-2CD) |
| Net Weight | 115 kg (BJ-1CD) / 205 kg (BJ-2CD) |
| Work Area Dimensions | 830 × 700 × 520 mm (BJ-1CD) / 1300 × 700 × 520 mm (BJ-2CD) |
| External Dimensions | 891 × 725 × 1577 mm (BJ-1CD) / 1460 × 725 × 1577 mm (BJ-2CD) |
| HEPA Filter Specifications | 765 × 548 × 50 mm × 1 (BJ-1CD) / 1236 × 549 × 50 mm × 1 (BJ-2CD), Unibody Pleated HEPA, ≥99.995% @ 0.3 µm |
| Pre-filter | Synthetic Fiber Medium-Efficiency Panel Filter |
| Lighting | 30 W Fluorescent Lamp × 1 + 20 W UV Lamp × 1 (BJ-1CD) / 40 W Fluorescent Lamp × 1 + 30 W UV Lamp × 1 (BJ-2CD) |
| Safety Interlock | UV Lamp & Main Light Interlocked |
| Control Interface | LCD Display with Real-Time Parameters (Air Velocity, Differential Pressure, Cumulative Operating Time, Clock, HEPA Status) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-1CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 830 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 990 × 744 × 1680 mm |
| HEPA Filter Specification | 800 × 604 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Fan Type | High-efficiency centrifugal blower |
| Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Illumination | ≥300 lx (30 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.2 kW |
| Net Weight | 115 kg |
| Work Surface Material | SUS304 brushed stainless steel |
| Cabinet Material | Cold-rolled steel with epoxy-powder coating |
| Control Interface | LCD display with multi-parameter monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-1CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 830 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 990 × 744 × 1680 mm |
| HEPA Filter Specification | 800 × 604 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Illumination | ≥300 lux (30 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.2 kW |
| Net Weight | 115 kg |
| Control Interface | LCD display with multi-parameter readout (air velocity, cumulative operating time, filter pressure differential, clock, HEPA status) |
| Safety Features | Interlocked UV and lighting circuits, audible/visual HEPA failure alarm, sash position sensing, splash-proof internal power sockets, integrated gas/water ports |
| Construction | Cold-rolled steel outer casing, SUS304 brushed stainless steel work surface |
| Ergonomics | 5° forward-sloping front panel, counterbalanced vertical sliding sash, casters with leveling feet |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-2CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Working Surface Dimensions | 1300 × 700 × 495 mm (W × D × H) |
| Overall Dimensions | 1460 × 744 × 1680 mm (W × D × H) |
| HEPA Filter Specification | 1270 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 40 W) |
| UV Lamp | 30 W, germicidal |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Adjustable Air Velocity Range | 0.3–0.6 m/s (6-step digital setpoint with real-time display) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.37 kW |
| Net Weight | 205 kg |
| Control Interface | LCD panel with multi-parameter real-time monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-2CD |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Work Surface Dimensions (W×D×H) | 1300 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1460 × 744 × 1680 mm |
| HEPA Filter Specification | 1270 × 604 × 50 mm (1 unit) |
| Illumination | ≥300 lx (40 W fluorescent lamp) |
| UV Sterilization Lamp | 30 W |
| Operating Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Amplitude (Peak-to-Peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.37 kW |
| Net Weight | 205 kg |
| Display | LCD with multi-parameter readout (air velocity, cumulative operating time, filter differential pressure, clock, HEPA status) |
| Safety Features | Interlocked UV and lighting circuits, HEPA integrity alarm (audible + visual), pre-filter + HEPA dual-stage filtration, counterbalanced sash, 5° ergonomic front tilt, integrated splash-proof power sockets and utility ports (gas/water) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-3CD |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| Airflow Pattern | Vertical Downflow |
| Rated User Capacity | Three-person, single-sided operation |
| Working Surface Dimensions (W×D×H) | 1800 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1960 × 744 × 1680 mm |
| HEPA Filter Specification | 1770 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 30 W × 2) |
| UV Lamp | 30 W × 1 |
| Average Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.55 kW |
| Net Weight | 280 kg |
| Construction Materials | Cold-rolled steel housing |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-3CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Three-person single-sided operation |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 1800 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1960 × 744 × 1680 mm |
| HEPA Filter Specification | 1770 × 604 × 50 mm (1 unit) |
| Illumination | ≥300 lux (30 W fluorescent ×2) |
| UV Lamp | 30 W ×1 |
| Operating Wind Speed Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.55 kW |
| Net Weight | 280 kg |
| Control Interface | LCD panel with multi-parameter real-time monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-130 |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±1.9°C |
| Temperature Fluctuation (at 150°C) | ±0.3°C |
| Recovery Time (30°C deviation at 150°C) | 8 min |
| Heating Method | Forced-air Circulation |
| Interior Dimensions (L×W×H, mm) | 570×400×570 |
| Exterior Dimensions (L×W×H, mm) | 715×616×842 |
| Interior Material | Stainless Steel (SUS304) |
| Rated Power | 1.8 kW |
| Standard Shelving | 2 adjustable stainless steel shelves (max. 7) |
| Control System | PID-based digital temperature controller with LCD display |
| Programmability | 10 segments × 100 cycles |
| Timer Range | 0–99 h 59 min |
| Fan Speed Control | 5-step adjustable |
| Communication Interface | Standard RS-485 port |
| Optional Accessories | Thermal printer (domestic or Epson OEM), FDA/GMP-compliant monitoring software, GPRS SMS alarm module, wireless temperature data logger (validated up to 130°C, with calibration certificate at 0°C, 60°C, and 121°C) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-130G |
| Instrument Type | Precision Drying Oven |
| Temperature Range | Ambient + 2°C to 300°C |
| Temperature Uniformity | ±1.9°C at 150°C |
| Temperature Fluctuation | ±0.3°C at 150°C |
| External Dimensions (W×D×H) | 715 × 616 × 842 mm |
| Internal Chamber Dimensions (W×D×H) | 570 × 400 × 570 mm |
| Chamber Volume | 129 L |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Forced-air Circulation with Adjustable Fan Speed (6-step) and Motorized Air Damper |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 2150 W |
| Temperature Resolution | 0.1°C |
| Ramp Time | ≤20 min to 150°C |
| Timer Range | 0–9999 min/h |
| Programmable Cycle | 10 segments × 100 cycles |
| Standard Accessories | RS-485 interface, 2 stainless steel shelves (max. 7), shelf load capacity: 25 kg per shelf |
| Optional Accessories | Additional shelves, thermal printer (domestic or Epson imported), FDA-compliant monitoring software, GMP-compliant monitoring software, GPRS SMS alarm module |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXH-130S |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±1.9°C |
| Temperature Fluctuation (at 150°C) | ±0.3°C |
| Recovery Time (30 s, at 150°C) | 8 min |
| Heating Method | Forced Air Circulation |
| Inner Chamber Dimensions (L×W×H) | 570 × 400 × 570 mm |
| External Dimensions (L×W×H) | 735 × 665 × 755 mm |
| Inner Chamber Material | Stainless Steel (AISI 304) |
| Rated Power | 1.8 kW |
| Standard Shelving | 2 adjustable stainless steel shelves (up to 7 optional) |
| Programmability | 30 segments × 99 cycles |
| Ramp/Soak Control | Yes, with programmable heating/cooling rates |
| Data Logging Capacity | 4 million records |
| Interface | Dual RS-485 ports + 1 USB port |
| Cooling Mode | Post-cycle forced-air rapid cooling |
| Safety | Dual independent overtemperature protection (PID-controlled sensor + mechanical thermal cutoff) |
| Fan Speed Control | 5-step adjustable |
| Exhaust Damper Control | 10-position adjustable air exhaust valve |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-210 |
| Price Range | USD 1,150 – 2,150 (FOB) |
| Instrument Type | Precision Forced-Air Oven |
| Temperature Range | RT + 5°C to 300°C |
| Temperature Uniformity | ±1.5°C at 150°C |
| Temperature Fluctuation | ±0.5°C at 150°C |
| Resolution | 0.1°C |
| Chamber Volume | 210 L |
| Interior Dimensions | 630 × 530 × 630 mm |
| Exterior Dimensions | 775 × 746 × 902 mm |
| Interior Material | Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-stage) |
| Power Rating | 2750 W |
| Timer Range | 0–9999 min/h |
| Programmable Stages | 10 segments × 100 cycles |
| Fan Motor | EC-type, brushless, speed-controllable |
| Door Seal | Dual-stage rotary locking mechanism with high-compression silicone gasket |
| Standard Interface | RS-485 |
| Standard Shelves | 3 (max. 7), load capacity 25 kg per shelf |
| Preheating Chamber | Integrated for rapid thermal equilibration and improved temperature homogeneity |