Common Laboratory Equipment
Filter
Showing 1831–1860 of 17607 results
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-210G |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity | ±1.5°C at 150°C |
| Temperature Fluctuation | ±0.5°C at 150°C |
| Resolution | 0.1°C |
| Chamber Volume | 210 L |
| Interior Dimensions | 630 × 530 × 630 mm (W×D×H) |
| Exterior Dimensions | 775 × 746 × 902 mm (W×D×H) |
| Interior Material | Stainless Steel (SUS304) |
| Heating Method | Forced-air Circulation with Preheated Air Inlet |
| Power Rating | 2750 W |
| Timer Range | 0–9999 min/h |
| Programmable Stages | 10 segments × 100 cycles |
| Fan Speed Control | 6-step Adjustable |
| Motorized Air Damper | Yes |
| Dual Over-Temperature Protection | Independent Sensor + Mechanical Safety Thermostat |
| Standard Accessories | RS-485 Interface, 3 Adjustable Shelves (25 kg load capacity per shelf), Inlet/Exhaust Filters |
| Optional Accessories | Additional Shelves, Thermal Printer (Domestic or Epson OEM), FDA/GMP-Compliant Monitoring Software, GPRS SMS Alarm Module |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-280 |
| Price Range | USD 2,100 – 4,200 (FOB) |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±2.2°C |
| Temperature Fluctuation (at 150°C) | ±0.5°C |
| Recovery Time (30 s after 150°C disturbance) | 8 min |
| Heating Method | Forced-air Circulation |
| Chamber Material | Stainless Steel (SUS304) |
| External Dimensions (L×W×H, mm) | 865×746×1019 |
| Internal Dimensions (L×W×H, mm) | 720×530×745 |
| Standard Shelving | 3 stainless steel trays (max. 9) |
| Rated Power | 2.7 kW |
| Ramp-up Time to 150°C | 20 min |
| Control System | PID Analog Regulation |
| Display | LCD with Real-time Setpoint/Actual Temperature, Operating Status, Fan Speed Stage, and Cycle Progress |
| Programmable Stages | 10 segments × 100 cycles |
| Timer Function | Up to 99 h 59 min |
| Fan Speed Control | 5-step Adjustable |
| Communication Interface | Standard RS-485 port |
| Optional Accessories | Thermal Printer (domestic or Epson OEM), FDA/GMP Compliance Monitoring Software, GPRS SMS Alert Module, Wireless Temperature Data Logger (validated up to 130°C, includes calibration certificate at 0°C, 60°C, 121°C), Additional Stainless Steel Trays |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-280G |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity | ±2.2°C (at 150°C) |
| Temperature Fluctuation | ±0.5°C (at 150°C) |
| Resolution | 0.1°C |
| Chamber Volume | 284 L |
| Interior Dimensions | 720 × 530 × 745 mm |
| Exterior Dimensions | 865 × 746 × 1019 mm |
| Interior Material | Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Preheated Air Inlet |
| Power Rating | 2750 W |
| Ramp Time | ≤20 min (to 150°C) |
| Standard Shelving | 3 adjustable shelves (max 9) |
| Shelf Load Capacity | 25 kg per shelf |
| Standard Interface | RS-485 |
| Optional Accessories | Additional Shelves, Thermal Printer (Domestic/Imported), FDA-Compliant Monitoring Software, GMP-Compliant Monitoring Software, GPRS SMS Alarm Module |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-280S |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±2.2°C |
| Temperature Fluctuation (at 150°C) | ±0.5°C |
| Recovery Time (30 s, at 150°C) | 8 min |
| External Dimensions (L×W×H, mm) | 885×930×795 |
| Internal Chamber Dimensions (L×W×H, mm) | 720×745×530 |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Circulation with Rear-Mounted Heater |
| Ramp/Soak Programming | 30 segments × 99 cycles |
| Data Storage Capacity | 4 million records |
| Interface | Dual RS-485 ports + 1 USB port |
| Cooling Mode | Post-cycle rapid cooling fan activation |
| Safety | Dual independent overtemperature protection (PID-controlled sensor + mechanical cut-off switch) |
| Airflow Control | 5-step fan speed + 10-step adjustable exhaust damper |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-450G |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT + 5°C to 300°C |
| Temperature Uniformity | ±2.5°C at 150°C |
| Temperature Fluctuation | ±0.5°C at 150°C |
| Resolution | 0.1°C |
| Chamber Volume | 452 L |
| Interior Dimensions | 600 × 630 × 1300 mm |
| Exterior Dimensions | 774 × 845 × 1704 mm |
| Interior Material | Stainless Steel (SUS304) |
| Heating Method | Forced-air Circulation with Preheated Air Inlet |
| Power Rating | 3500 W |
| Ramp Time | ≤22 min to 150°C |
| Standard Shelving | 3 adjustable shelves (max 9) |
| Shelf Load Capacity | 25 kg per shelf |
| Standard Interface | RS-485 |
| Filtration | Integrated Inlet/Exhaust Filters |
| Programmability | 10-segment, 100-cycle profile control |
| Fan Speed Control | 6-step adjustable |
| Motorized Air Damper | Yes |
| Dual Independent Over-Temperature Protection | Sensor-based + Mechanical Safety Cut-off |
| Timer & Delay Start | 0–9999 min/h |
| Optional Software | FDA 21 CFR Part 11–compliant Monitoring Software (GMP/FDA Edition), GPRS SMS Alert Module, Thermal Printer (Domestic or Epson OEM) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-530S |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±2.5°C |
| Temperature Fluctuation (at 150°C) | ±0.5°C |
| Recovery Time (30 s, at 150°C) | 9 min |
| External Dimensions (L×W×H, mm) | 1235×850×1080 |
| Internal Chamber Dimensions (L×W×H, mm) | 1070×595×835 |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Rear-Mounted Heater |
| Ramp/Soak Programming | 30 segments × 99 cycles |
| Data Storage Capacity | 4 million records |
| Interface Standard | Dual RS-485 ports + 1 USB port |
| Power Rating | 3.5 kW |
| Standard Shelf Configuration | 3 shelves (max. 12) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-65 |
| Price Range | USD 1,100 – 2,100 |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±2°C |
| Temperature Fluctuation (at 150°C) | ±0.3°C |
| Recovery Time (30 s, at 150°C) | 7 min |
| External Dimensions (L×W×H, mm) | 550×566×722 |
| Internal Chamber Dimensions (L×W×H, mm) | 410×450×450 |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Rear-Mounted Heater |
| Power Rating | 1.5 kW |
| Standard Shelving | 2 stainless steel trays (max. 5) |
| Programmability | 10 segments × 100 cycles |
| Timer Range | 0–99 h 59 min |
| Control System | PID Analog Regulation |
| Fan Speed Control | 5-step adjustable |
| Communication Interface | Standard RS-485 port |
| Optional Accessories | FDA/GMP-compliant monitoring software, thermal printer (domestic or Epson OEM), GPRS SMS alarm module, wireless temperature data logger (≤130°C, with calibration certificate at 0°C, 60°C, 121°C), validation-ready data analysis software |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXH-65G |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity | ±2°C (at 150°C) |
| Temperature Fluctuation | ±0.3°C (at 150°C) |
| Resolution | 0.1°C |
| Chamber Volume | 64 L |
| Interior Dimensions | 410 × 350 × 450 mm |
| Exterior Dimensions | 555 × 566 × 722 mm |
| Interior Material | Stainless Steel (SUS304) |
| Heating Method | Forced-air Circulation with Preheated Air Inlet |
| Power Rating | 1550 W |
| Ramp Time | ≤17 min (to 150°C) |
| Timer Range | 0–9999 min/h |
| Programmable Stages | 10 segments × 100 cycles |
| Fan Speed Control | 6-step Adjustable |
| Motorized Air Damper | Yes |
| Dual Over-Temperature Protection | Independent Sensor + Mechanical Thermal Cut-off |
| Standard Interfaces | RS-485 |
| Standard Shelves | 2 (max. 5), Load Capacity per Shelf: 25 kg |
| Optional Accessories | Additional Shelves, Thermal Printer (Domestic/Imported), FDA/GMP-Compliant Monitoring Software, GPRS SMS Alarm Module |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | BXH-65S |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity (at 150°C) | ±2°C |
| Temperature Fluctuation (at 150°C) | ±0.3°C |
| Recovery Time (30 s, at 150°C) | 7 min |
| Heating Rate (to 150°C) | 17 min |
| External Dimensions (L×W×H, mm) | 575×635×615 |
| Internal Chamber Dimensions (L×W×H, mm) | 410×450×350 |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Forced-Air Circulation with Rear-Mounted Heater |
| Control System | PID Analog Regulation |
| Programmability | 30 segments × 99 cycles |
| Data Storage Capacity | 4 million records |
| Interface Ports | 2 × RS-485, 1 × USB |
| Fan Speed Control | 5-step adjustable |
| Exhaust Damper Control | 10-step adjustable |
| Cooling Mode | Post-cycle rapid cooling |
| Safety | Dual independent overtemperature protection (sensor-based + mechanical thermostat) |
| Optional Accessories | FDA/GMP-compliant monitoring software, thermal printer (Epson or domestic thermal), GPRS SMS alarm module, wireless temperature validation probes (≤130°C, NIST-traceable calibration certificate for 0°C/60°C/121°C), HEPA-filtered air inlet (Class 100 clean air) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-100 |
| Price Range | USD 2,100 – 4,200 (est.) |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions (W×D×H) | 620 × 640 × 1165 mm |
| Internal Chamber Dimensions (W×D×H) | 450 × 500 × 450 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Heated Shelf System with Independent Zone Control |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 100 L |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 1400 W |
| Timer Range | 0–9999 min |
| Shelving | 2 adjustable heated shelves with individual temperature monitoring and control |
| Noise Reduction | Integrated acoustic enclosure for vacuum pump (−40 dB(A) vs. external pump setup) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BXK-100S |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| Internal Chamber Dimensions (mm) | 450 × 500 × 450 |
| External Dimensions (mm) | 620 × 640 × 1165 |
| Chamber Volume | 100 L |
| Chamber Material | Stainless Steel (304) |
| Heating Method | Heated Shelf (Uniformly Distributed Under-Shelf Heating Elements) |
| Vacuum Degree | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 1400 W |
| Timer Range | 0–9999 min |
| Shelving | 2 Adjustable Stainless Steel Shelves with Independent Temperature Control |
| Door | Double-Layer Tempered Glass with Silicone Gasket |
| Control System | Microprocessor-Based Digital Controller with LCD Display, Over-Temperature Alarm, Power Failure Recovery, and Vacuum Monitoring & Auto-Compensation |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-250 |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions | 770 × 780 × 1515 mm |
| Internal Chamber Dimensions | 600 × 600 × 700 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Bottom-mounted Heated Shelving with Forced Convection |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 250 L |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 2200 W |
| Timer Range | 0–9999 min |
| Shelving | 3 pcs, independently temperature-controlled |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-250S |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.3°C |
| External Dimensions (W×D×H) | 770×780×1515 mm |
| Internal Chamber Dimensions (W×D×H) | 600×600×700 mm |
| Chamber Material | Stainless Steel |
| Heating Method | Shelf-Mounted Heaters with Forced Convection |
| Vacuum Level | 133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 250 L |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 2200 W |
| Timer Range | 0–9999 min |
| Number of Adjustable Shelves | 3 (Individually Temperature-Controlled) |
| Display | LCD Microprocessor Controller |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | BOXUN (OEM/ODM Capable) |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| Chamber Volume | 30 L |
| Internal Dimensions | 320 × 320 × 300 mm |
| External Dimensions | 480 × 530 × 1015 mm |
| Inner Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Bottom-mounted Heated Shelving with Independent Shelf Temperature Control |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 450 W |
| Timer Range | 0–9999 min |
| Shelf Configuration | 1 Adjustable Heated Shelf (Individually Controlled) |
| Door | Dual-layer Tempered Glass with Silicone Gasket Seal |
| Control System | Microprocessor-based PID Controller with LCD Display, Over-Temperature Alarm, Auto-Restart After Power Failure |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BXK-30S |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| Chamber Dimensions (W×D×H) | 320 × 320 × 300 mm |
| External Dimensions (W×D×H) | 480 × 530 × 1015 mm |
| Chamber Volume | 30 L |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Heated Shelf (Uniform Bottom-Mounted Heating Elements) |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 450 W |
| Timer Range | 0–9999 minutes |
| Shelf Configuration | 1 independently temperature-controlled shelf |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-50 |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions | 575 × 550 × 1060 mm |
| Internal Chamber Dimensions | 415 × 370 × 345 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Bottom-Mounted Heated Shelving with Independent Shelf Temperature Control |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 53 L |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 900 W |
| Timer Range | 0–9999 minutes |
| Shelving | 2 pcs, independently temperature-controlled |
| Door | Double-layer tempered glass with silicone gasket seal |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-500 |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions (W×D×H) | 800×990×1660 mm |
| Internal Chamber Dimensions (W×D×H) | 630×810×845 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Heated Shelf System with Independent Zone Control |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 500 L |
| Power Supply | 380 V ±10%, 50/60 Hz |
| Rated Power | 3900 W |
| Timer Range | 0–9999 min |
| Standard Shelves | 4 pcs (individually temperature-controlled) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Boxun Scientific Instrument Co., Ltd. |
| Type | Vacuum Drying Oven |
| Model | BXK-500S |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| Chamber Dimensions (W×D×H) | 630 × 810 × 845 mm |
| External Dimensions (W×D×H) | 800 × 990 × 1660 mm |
| Chamber Volume | 500 L |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Heated Shelf System (Multi-zone Independent Control) |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Power Supply | 380 V ±10%, 50/60 Hz |
| Rated Power | 3900 W |
| Timer Range | 0–9999 min |
| Shelf Quantity | 4 pcs (individually temperature-controlled) |
| Display | LCD with Microprocessor-based Controller |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXK-50S |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions (W×D×H) | 575 × 550 × 1060 mm |
| Internal Chamber Dimensions (W×D×H) | 415 × 370 × 345 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Bottom-mounted Heated Shelf with Independent Temperature Control |
| Vacuum Performance | Ultimate Vacuum ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 53 L |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 900 W |
| Timer Range | 0–9999 minutes |
| Shelf Configuration | 2 adjustable stainless steel shelves, each with independent temperature control and real-time digital display |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-100M |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-100M |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying) | 0–999 min |
| Time Range (Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Cooling Method | Integrated Axial Fan (Forced Air) |
| Air Intake Filtration | Built-in HEPA-grade Filter |
| Water Supply | Dual-channel (Deionized/Pure Water & Tap Water) |
| Standard Probe | Single-channel Sample Temperature Sensor |
| C.W.S. Condensate Reuse System | Yes |
| W.P.S. Waste Gas & Effluent Purification System | Yes |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Time | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Operating Ambient | 5–40 °C, 20–80 % RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature cutoff, dry-run protection, overpressure mechanical & electronic relief, anti-scald insulation, overload, short-circuit, and leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Programmability | 8 pre-set + 6 user-defined cycles |
| Air Removal | 6-stage positive-pressure pulse with adjustable vacuum-assisted preheating |
| Exhaust Control | 6-level programmable depressurization rate |
| Optional Accessories | 0.2 µm high-temp/pressure exhaust filter, thermal printer with F₀ logging capability (requires optional sample probe), validation port adapter, wired temperature validation interface |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Drying Duration | 10–6000 min |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Interface | Capacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-120M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 740 mm |
| External Dimensions | 850 × 910 × 1080 mm |
| Chamber Volume | 120 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Efficiency | <1% residual moisture |
| Heating Power | 9.9 kW |
| Power Supply | ~380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air cooling with built-in fan |
| Air Intake Filtration | Integrated HEPA-grade air filter |
| Dual Water Inlet System | Selectable pure water or tap water supply |
| Standard Sample Temperature Probe | Real-time monitoring of load temperature |
| C.W.S. Condensate Water Reuse System | Recirculates sterilization condensate |
| W.P.S. Waste Processing System | Filters and purifies exhaust steam and condensate prior to discharge |
| Safety Features | Mechanical self-locking + electronic interlock door mechanism, overtemperature cutoff, independent safety limiter, overpressure auto-relief, fault self-diagnosis, water-level auto-refill |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-120M |
| Instrument Type | Vertical Sterilizer |
| Max Operating Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 740 mm |
| External Dimensions | 850 × 910 × 1080 mm |
| Chamber Volume | 120 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Heating/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 9.9 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-150M |
| Instrument Type | Vertical Steam Sterilizer |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp Range | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 0–999 min |
| Melting/Holding Time Range | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-150M |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Warming/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-30R |
| Instrument Type | Vertical |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temp. | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BXM-30R |
| Instrument Type | Vertical Sterilizer |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temperature | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |