Empowering Scientific Discovery

Cytiva (Cytiva China)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham Typhoon IP
Dynamic Range>5 decades
Scan Area40 × 46 cm
Imaging ModesPhosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD)
Detector TypeHigh-Sensitivity PMT-based Scanning System
LensFujifilm Precision Optics
ComplianceSupports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham Typhoon NIR / NIR+
Instrument TypeMulticolor Fluorescent Gel Imaging System
Detection PrincipleConfocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering
Laser Wavelengths685 nm, 785 nm
Emission FiltersIRshort 720BP20, IRlong 825BP30
Scan ModesAutomatic, Semi-Automatic, Manual
Sample FormatsSDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections
DetectorEnhanced Photomultiplier Tube (PMT) optimized for NIR spectral range
Dynamic Range>4 orders of magnitude (log-linear response)
Spatial Resolution≤50 µm (pixel size adjustable)
Software PlatformImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham ImageQuant 500
Imaging TypeChemiluminescence
CCD Resolution8.3 MP
Dynamic Range4.8 decades
Lens Aperturef/0.14 (Fujifilm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham ImageQuant 800
Imaging TypeChemiluminescence Gel Imager
CCD Resolution8.3 MP
LensFujinon F0.74
LED ChannelsRGB, NIR-short, NIR-long, UV, Side-reflected white light, Transmitted white light
GxP Compliance ModuleOptional FDA 21 CFR Part 11 / EU GMP Annex 11 Ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUnited Kingdom
ModelAmersham DIGE Unit LF24
Gel Dimensions255 × 186 × 1 mm
External Dimensions277 × 217 × 7 mm
Max. Simultaneous Gels (Electrophoresis)2
Max. Simultaneous Gels (Transfer)2
Max. Voltage800 V
Max. Current400 mA
Max. Power100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham Typhoon RGB
Imaging ModesMulticolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD)
Pixel ResolutionDown to 10 µm
Scan AreaUp to 40 × 46 cm (Typhoon 5/RGB)
Dynamic Range>5 orders of magnitude
Detection SensitivityAs low as 3 pg protein (fluorescently labeled)
Laser Configuration5-laser platform (Typhoon 5)
Detector TypeHigh-gain Photomultiplier Tubes (PMTs)
Upgrade PathField-upgradable across models
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelEttan IPGphor 3
Instrument TypeIsoelectric Focusing (IEF) Electrophoresis System
Gel Format CompatibilityIPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm)
Sample CapacityUp to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold
Voltage Range0–10,000 V (programmable ramping and stepwise control)
Current Limit0–100 µA–100 mA (auto-adjusting)
Temperature Control Range15–30 °C (±0.1 °C stability)
Dimensions (W×D×H)278 × 160 × 471 mm
On-device Method Storage10 methods (9 steps each)
PC Software ControlEttan IPGphor 3 Control Software (supports up to 4 instruments simultaneously)
Data LoggingReal-time voltage, current, and kV·h monitoring with graphical export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelTE22
Instrument TypeWet Protein Electrophoretic Transfer System
Gel CapacityUp to 4 × 9 cm × 10 cm gels per run
Cooling SystemIntegrated aluminum heat exchanger with recirculating buffer cooling
Temperature Rise≤5°C during standard transfer
Buffer Volume Requirement1 L per full-load run (4 gels)
Cassette DesignOpen-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying
ComplianceDesigned for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelEttan 2D DIGE
Instrument TypeTwo-Dimensional Fluorescent Differential Gel Electrophoresis System
Core ComponentsEttan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software
Sample CapacityUp to 3 samples co-separated per 2D gel
SensitivityQuantitative detection of ≤10% protein abundance change with ≥95% statistical confidence
Minimum Sample RequirementAs low as 5 µg total protein per sample
ComplianceDesigned for GLP-compliant proteomics workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare