| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon IP |
| Dynamic Range | >5 decades |
| Scan Area | 40 × 46 cm |
| Imaging Modes | Phosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD) |
| Detector Type | High-Sensitivity PMT-based Scanning System |
| Lens | Fujifilm Precision Optics |
| Compliance | Supports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 500 |
| Imaging Type | Chemiluminescence |
| CCD Resolution | 8.3 MP |
| Dynamic Range | 4.8 decades |
| Lens Aperture | f/0.14 (Fujifilm) |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 800 |
| Imaging Type | Chemiluminescence Gel Imager |
| CCD Resolution | 8.3 MP |
| Lens | Fujinon F0.74 |
| LED Channels | RGB, NIR-short, NIR-long, UV, Side-reflected white light, Transmitted white light |
| GxP Compliance Module | Optional FDA 21 CFR Part 11 / EU GMP Annex 11 Ready |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Model | Amersham DIGE Unit LF24 |
| Gel Dimensions | 255 × 186 × 1 mm |
| External Dimensions | 277 × 217 × 7 mm |
| Max. Simultaneous Gels (Electrophoresis) | 2 |
| Max. Simultaneous Gels (Transfer) | 2 |
| Max. Voltage | 800 V |
| Max. Current | 400 mA |
| Max. Power | 100 W |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon RGB |
| Imaging Modes | Multicolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD) |
| Pixel Resolution | Down to 10 µm |
| Scan Area | Up to 40 × 46 cm (Typhoon 5/RGB) |
| Dynamic Range | >5 orders of magnitude |
| Detection Sensitivity | As low as 3 pg protein (fluorescently labeled) |
| Laser Configuration | 5-laser platform (Typhoon 5) |
| Detector Type | High-gain Photomultiplier Tubes (PMTs) |
| Upgrade Path | Field-upgradable across models |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan IPGphor 3 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Format Compatibility | IPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm) |
| Sample Capacity | Up to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold |
| Voltage Range | 0–10,000 V (programmable ramping and stepwise control) |
| Current Limit | 0–100 µA–100 mA (auto-adjusting) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Dimensions (W×D×H) | 278 × 160 × 471 mm |
| On-device Method Storage | 10 methods (9 steps each) |
| PC Software Control | Ettan IPGphor 3 Control Software (supports up to 4 instruments simultaneously) |
| Data Logging | Real-time voltage, current, and kV·h monitoring with graphical export |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | TE22 |
| Instrument Type | Wet Protein Electrophoretic Transfer System |
| Gel Capacity | Up to 4 × 9 cm × 10 cm gels per run |
| Cooling System | Integrated aluminum heat exchanger with recirculating buffer cooling |
| Temperature Rise | ≤5°C during standard transfer |
| Buffer Volume Requirement | 1 L per full-load run (4 gels) |
| Cassette Design | Open-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying |
| Compliance | Designed for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan 2D DIGE |
| Instrument Type | Two-Dimensional Fluorescent Differential Gel Electrophoresis System |
| Core Components | Ettan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software |
| Sample Capacity | Up to 3 samples co-separated per 2D gel |
| Sensitivity | Quantitative detection of ≤10% protein abundance change with ≥95% statistical confidence |
| Minimum Sample Requirement | As low as 5 µg total protein per sample |
| Compliance | Designed for GLP-compliant proteomics workflows |