Cytiva (Cytiva China)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelÄKTA ready™
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Model29-0182-24
Purification PrincipleAffinity Chromatography (AC)
Detector TypeXenon Lamp UV-Vis Detector
Absorbance Range±6 AU
Weight48 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ start
Purification PrincipleAffinity Chromatography (AC)
Gradient TypeLinear Gradient
Flow Rate Range0.5–5 mL/min
Flow Accuracy±15% at ≤1 mL/min
Flow Precision±15% at ≤1 mL/min
DetectionUV Monitor (280 nm single-wavelength), Conductivity Monitor
Pressure Range0–0.5 MPa
Conductivity Range0–300 mS/cm
Solvent CompatibilityCompatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelAKTA avant
Purification PrincipleAffinity Chromatography (AC)
Detector TypeXenon Lamp UV-Vis Detector
Detection RangeUV 190–700 nm
System Pressure RatingUp to 20 MPa
Flow Rate Range0.001–20 mL/min (AKTA avant 25)
Conductivity Accuracy±0.01 mS/cm or ±2%
UV Absorbance Range–6 to +6 AU
pH Measurement Range0–14 pH units (±0.1 pH accuracy, pH 2–12)
Temperature Control Range4–35 °C
Column Pressure Differential MonitoringDual integrated pressure sensors (pre- and post-column)
Buffer PreparationIntegrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display
Software PlatformUNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control
Dimensions (L×W×H)860 × 710 × 660 mm
Weight116 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ pure micro
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
Flow Rate Range0.001–25 mL/min
Flow Accuracy±1.2% (absolute), RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP)
UV Detection Range190–700 nm (multi-wavelength)
Conductivity Range0.01–999.99 mS/cm
Optional pH Sensor0–14 pH, ±0.1 pH (pH 2–12)
Pressure Range0–20 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning
Internal System VolumeAs low as 18 µL (with micro kit)
Microfluidic Components0.8 µL injection valve, 2.6 µL UV flow cell, 5.4 µL conductivity cell, 0.7 µL outlet valve, 0.6 mL mixer, tubing ID: 0.13 mm or 0.25 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelAKTAcrossflow
Application ScopeLab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening
Max Total Membrane Area150 cm² (3 × 50 cm² cassettes)
Minimum Working Volume25 mL
Control SoftwareUNICORN v7.x or later
ComplianceDesigned for GLP/GMP-aligned workflows
Fluid Path MaterialsUSP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ go
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
Flow Rate Range0.01–25 mL/min
Flow Accuracy±2% (at 0.25–25 mL/min, 0.7–3 cP)
Detection OptionsUV monitor (280 nm fixed wavelength), Conductivity monitor (0.01–999.99 mS/cm), pH monitor (range 0–14, accuracy ±0.1 pH units within pH 2–12, ±3°C from calibration temperature)
Pressure Range0–5 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning per day
External Detector SupportFluorescence detector, refractive index detector, and other third-party detectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ pure 25M
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
Flow Rate Range0.001–25 mL/min (up to 50 mL/min in column packing mode)
Flow Rate Accuracy±1.2% (accuracy), RSD <0.5% (precision
conditions0.25–25 mL/min, <3 MPa, 0.8–2 cP)
Detection RangeUV detector (190–700 nm multi-wavelength for M-series), conductivity detector (0.01–999.99 mS/cm), pH detector (0–14 range, ±0.1 pH unit accuracy within pH 2–12), optional external detectors (fluorescence, refractive index)
Pressure Range0–20 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours CIP per day
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelBioProcess pcc 1/2"
Control SoftwareUNICORN™ or DeltaV™
Column Configuration3-column (3C) or 4-column (4C)
ApplicationContinuous downstream purification of therapeutic proteins
Compliance FrameworkSupports FDA 21 CFR Part 11, GMP, and GLP audit trails via software configuration
Service SupportOptiRun™ lifecycle service packages available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA ready XL
Flow Rate Range45–3500 L/h
Compatible Column IDup to 1200 mm
Primary ApplicationGMP-compliant large-scale bioprocess purification
Software PlatformUNICORN 7+ with OPC UA connectivity
Regulatory SupportFDA 21 CFR Part 11 compliant audit trail, GMP documentation package available
Sensor TypeSingle-use, calibrated-in-place (CIP) pressure, UV, conductivity, and temperature sensors
FootprintCompact industrial design optimized for multi-product facility integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA pure™ T Chromatography System
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
DetectorsDual-wavelength UV monitor (260 & 280 nm), Conductivity monitor, pH monitor
Flow Rate RangeÄKTA pure™ 25T: 0.001–25 mL/min (up to 50 mL/min in column packing mode)
ÄKTA pure™ 150T0.01–150 mL/min (up to 300 mL/min in column packing mode)
Flow AccuracyÄKTA pure™ 25T: ±1.2% accuracy, RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP)
ÄKTA pure™ 150T±1.5% accuracy, RSD <0.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP)
Pressure RangeÄKTA pure™ 25T: 0–20 MPa
ÄKTA pure™ 150T0–5 MPa
Conductivity Range0.01–999.99 mS/cm
pH Measurement0–14 pH units, ±0.1 pH accuracy (pH 2–12)
Solvent CompatibilityCompatible with ≥1 mol/L NaOH and ≥2 mol/L NaCl for >3 hours of in-place cleaning per day
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelAKTA pcc
Purification PrincipleAffinity Chromatography (AC)
Detector TypeXenon Lamp UV-Vis Detector
Detection CapabilitiesUV Absorbance (280 nm, 254 nm), Conductivity, pH, Temperature, Pressure
Column Positions3 or 4
Post-Loading Wash (PLW) FunctionalityYes
Regulatory Compliance SupportFDA 21 CFR Part 11, EU Annex 11, GLP/GMP-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelÄKTA™ start
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA pcc
ApplicationPeriodic Counter-Current Chromatography (PCC) for Protein Purification
SoftwareUNICORN™ Control Software
Configuration Options3-Column (3C) or 4-Column (4C) Setup
Regulatory SupportChange Control Notification (CCN) Service
Service OfferingOptiRun™ Lifecycle Support Program
Compliance ContextDesigned for GMP-aligned process development and scale-up per ICH Q5, Q8, and Q9 principles
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelReadyToProcess Column
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA ready™ 450
System TypeSingle-Use Preparative Chromatography Platform
Flow Rate Range0.01–45 mL/min
Hold-Up Volume< 1.2 mL (system dead volume)
Pressure LimitUp to 20 bar
ComplianceDesigned for GMP-compliant small-scale bioprocessing
Sensor IntegrationIntegrated single-use conductivity, pH, UV, and temperature sensors
Fluidic PathPre-sterilized, gamma-irradiated disposable flow path kits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA go Protein Purification System
Flow Rate0.01–25 mL/min
Max Operating Pressure5 MPa
UV Wavelength280 nm
Conductivity Range0.01–999.99 mS/cm
pH Range (optional)0–14
Path Length (flow cell)2 mm (optional 5 mm)
Dimensions (W×D×H)335 × 464 × 482 mm
Weight27 kg
Power Consumption (typical)100 W
Safety Certifications2006/42/EC (MD), 2004/108/EC (EMC), 1999/5/EC (R&TTE)
IP RatingIP21
Tubing ID0.5 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA pure™ 150T
Maximum Flow Rate150 mL/min
UV Detection WavelengthsFixed at 260 nm and 280 nm
Software PlatformUNICORN 7
Column Switching CapacityUp to 10 columns via optional column selection valve
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Model28-9308-42
ApplicationPreparative Chromatography for Protein Purification
Flow Rate RangeUp to 25 mL/min
Max System Pressure20 MPa (200 bar)
UV Detection Range–6 to +6 AU
Conductivity Accuracy±0.01 mS/cm or ±2%
pH Measurement Range0–14, Accuracy ±0.1 pH (pH 2–12)
Temperature Monitoring Range0–99 °C, Accuracy ±1.5 °C (4–45 °C)
Fraction Collection Volume0.1–50 mL
Dimensions (L×W×H)860 × 710 × 660 mm
Weight116 kg
Operating Temperature4–35 °C
Relative Humidity20–95%, non-condensing
Power Consumption1100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelUniFlux™
System VariantsUniFlux™ 10, 30, 120, 400
Membrane Area Range0.11–52 m²
Feed Volume Capacity1–10,000+ L
Construction Materials316L Stainless Steel, USP Class VI Polymers
Control SoftwareUNICORN™ v7.x or later
Regulatory ComplianceFDA 21 CFR Part 11, GMP/GLP-Ready, cGMP-Compatible Design
Pressure Monitoring4 Real-Time Channels
Sensor IntegrationTemperature, UV Absorbance, pH, Conductivity, Air Flow, Transmembrane Pressure (TMP), Differential Pressure (ΔP), Crossflow & Permeate Flow Rates
Pump TypesSanitary Diaphragm & Rotary Lobe Pumps
Integrity TestIntegrated Air Flow-Based Filter Integrity Testing
CleaningFully Automated CIP Method Development & Water Flux Validation
Data ManagementAudit Trail, Electronic Signatures, 10-Tier User Access Control, Logbook Generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA pilot 600S
Application ScopeNon-GMP Process Development & Scale-up
Column ID Range26–200 mm
Flow Rate Range0.01–600 mL/min
Max Pressure20 MPa (200 bar)
System ArchitectureModular Benchtop Platform
Software PlatformUNICORN 7.x or later
Regulatory SupportAudit Trail, Electronic Signatures, User Access Levels (GMP-compliant configuration available in ÄKTA pilot 600R variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ avant 150
Purification PrincipleIon Exchange Chromatography (IEX)
Gradient TypeLinear Gradient
Flow Rate Range0.01–150 mL/min (up to 300 mL/min in column packing mode)
Flow Accuracy±1.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP)
PrecisionRSD <0.5%
Detection RangeUV-Vis detector (190–700 nm, multi-wavelength monitoring), Conductivity detector (0.01–999.99 mS/cm), pH detector (0–14, accuracy ±0.1 pH units within pH 2–12)
Pressure Range0–5 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours of in-place cleaning per day
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Model28-9062-61
ConfigurationPre-sterilized, disposable flow path system
Flow Rate Range50 mL/min to 510 L/hr
Column Diameter Compatibility70 mm – 450 mm
Regulatory ComplianceUSP Class VI biocompatible materials
Manufacturing EnvironmentISO 8 cleanroom packaging
DocumentationFull traceability, batch-specific validation dossiers, GMP-aligned support files