Empowering Scientific Discovery

Cytiva (Cytiva China)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelÄKTA ready™
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelOligoProcess™
Synthesis Scale10–1800 mmol per run
Regulatory ComplianceFDA 21 CFR Part 11, GMP-ready architecture
Software PlatformUNICORN 7.x or later
Column TechnologyFlow-through synthesis columns (compatible with ÄKTA oligopilot plus and OligoPilot 400)
ConstructionIndustrial-grade, explosion-proof certified components
Application ScopeClinical-phase development through commercial-scale cGMP manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham Typhoon IP
Dynamic Range>5 decades
Scan Area40 × 46 cm
Imaging ModesPhosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD)
Detector TypeHigh-Sensitivity PMT-based Scanning System
LensFujifilm Precision Optics
ComplianceSupports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelWAVE 20/50
Maximum Working Volume25 L
Tray Sizes5 L / 10 L / 25 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA readyflux
TypeSingle-Use Tangential Flow Filtration (TFF) System
Application ScopeLab-Scale to Pilot-Scale Bioprocessing
Control SoftwareUNICORN 7.x or later
CompatibilityDeltaV™ DCS, ReadyToProcess Hollow-Fiber Cartridges, Xcellerex XDUO Single-Use Mixers, Third-Party Bag Mixers
Regulatory AlignmentDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelXcellerex™ X-50
PricingUpon Request
Application DomainBiopharmaceutical Cell Culture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Model29-0182-24
Purification PrincipleAffinity Chromatography (AC)
Detector TypeXenon Lamp UV-Vis Detector
Absorbance Range±6 AU
Weight48 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelOmics Bundle
Separation MethodAutomated
Cell Viability (%)≥90%
CompatibilityRequires Integration with VIA Freeze™ Uno Controlled-Rate Freezer
Intended UseResearch Use Only (RUO), Not for Diagnostic Purposes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ start
Purification PrincipleAffinity Chromatography (AC)
Gradient TypeLinear Gradient
Flow Rate Range0.5–5 mL/min
Flow Accuracy±15% at ≤1 mL/min
Flow Precision±15% at ≤1 mL/min
DetectionUV Monitor (280 nm single-wavelength), Conductivity Monitor
Pressure Range0–0.5 MPa
Conductivity Range0–300 mS/cm
Solvent CompatibilityCompatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelAKTA avant
Purification PrincipleAffinity Chromatography (AC)
Detector TypeXenon Lamp UV-Vis Detector
Detection RangeUV 190–700 nm
System Pressure RatingUp to 20 MPa
Flow Rate Range0.001–20 mL/min (AKTA avant 25)
Conductivity Accuracy±0.01 mS/cm or ±2%
UV Absorbance Range–6 to +6 AU
pH Measurement Range0–14 pH units (±0.1 pH accuracy, pH 2–12)
Temperature Control Range4–35 °C
Column Pressure Differential MonitoringDual integrated pressure sensors (pre- and post-column)
Buffer PreparationIntegrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display
Software PlatformUNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control
Dimensions (L×W×H)860 × 710 × 660 mm
Weight116 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelBiacore 1K SPR System
ConfigurationSingle-injection needle, six-flow-cell platform
Regulatory ReadinessOptional GxP-compliant software package (21 CFR Part 11 audit trail enabled)
SoftwareBiacore Insight™ v3.x
Service SupportOptiRun™ lifecycle service program
Upgrade PathCompatible with Biacore 1K+ expansion module for enhanced ligand multiplexing and sample throughput
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham Typhoon NIR / NIR+
Instrument TypeMulticolor Fluorescent Gel Imaging System
Detection PrincipleConfocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering
Laser Wavelengths685 nm, 785 nm
Emission FiltersIRshort 720BP20, IRlong 825BP30
Scan ModesAutomatic, Semi-Automatic, Manual
Sample FormatsSDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections
DetectorEnhanced Photomultiplier Tube (PMT) optimized for NIR spectral range
Dynamic Range>4 orders of magnitude (log-linear response)
Spatial Resolution≤50 µm (pixel size adjustable)
Software PlatformImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSwitzerland
Instrument ModelSefia S-2000
TypeFully Automated
Regulatory DesignationImport (CE-marked for IVDR/MDR-compliant use in cell therapy manufacturing)
Single-Use Kit CompatibilityCT-300.1, CT-400.1 + PB-100.1, CT-200.1, CT-800.1, CT-350.1S
Software IntegrationChronicle™ v3.2+ with eSOP/eBMR and 21 CFR Part 11 / EU Annex 11 compliance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ pure micro
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
Flow Rate Range0.001–25 mL/min
Flow Accuracy±1.2% (absolute), RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP)
UV Detection Range190–700 nm (multi-wavelength)
Conductivity Range0.01–999.99 mS/cm
Optional pH Sensor0–14 pH, ±0.1 pH (pH 2–12)
Pressure Range0–20 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning
Internal System VolumeAs low as 18 µL (with micro kit)
Microfluidic Components0.8 µL injection valve, 2.6 µL UV flow cell, 5.4 µL conductivity cell, 0.7 µL outlet valve, 0.6 mL mixer, tubing ID: 0.13 mm or 0.25 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelUniFlux Tangential Flow Filtration System
Flow Rate Options10, 60, 120 L/min (400 L/min available on custom basis)
Vessel Capacity Range5–600 L (stainless steel or single-use mixing systems supported)
Automation PlatformUNICORN Software (21 CFR Part 11 compliant)
Application ScopeMicrofiltration (e.g., cell harvest) and Ultrafiltration (e.g., protein concentration & diafiltration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUSA
ModelReadyToProcess WAVE 25
Maximum Working Volume25 L
Drive MechanismMotorized Rocking Platform with Adjustable Speed, Angle, and Motion Profile
Temperature ControlIntegrated Heated Tray with Dual Independent PID Loops (Dual-Mode Operation)
Weight MeasurementBuilt-in Load Cells with Auto-Calibration Capability
Gas TransferPassive O₂/CO₂ Exchange via Sterile Vent Filters (Heated Exhaust Filter Included)
Data StorageDual Mirrored SSDs + UNICORN Database Integration
Communication ProtocolOPC UA Compliant
ComplianceDesigned for GMP Environment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSwitzerland
ModelNanoAssemblr™ Spark™ Instrument
Sample Volume Range25–250 µL
Mixing TechnologyNxGen™ Microfluidic Vortex Mixing
Sterility DesignBSC-Compatible, Aseptic Operation Ready
Chip TypeSingle-Use, Gamma-Irradiated Cartridge
Scalability PathwaySeamless Transition to NanoAssemblr™ Ignite™ and NxGen™ Production Platforms
Regulatory ContextDesigned for GLP-compliant early-stage development, supports 21 CFR Part 11–ready software integration (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelAKTAcrossflow
Application ScopeLab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening
Max Total Membrane Area150 cm² (3 × 50 cm² cassettes)
Minimum Working Volume25 mL
Control SoftwareUNICORN v7.x or later
ComplianceDesigned for GLP/GMP-aligned workflows
Fluid Path MaterialsUSP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBiacore 1S+ SPR System
Instrument TypeSurface Plasmon Resonance (SPR)
Flow Cell ConfigurationSix parallel flow cells
Detection RangefM to mM
Sample CapacityUp to two 96-well or 384-well microplates plus 21–43 additional sample positions
Analysis Time per Cycle2–15 minutes
Temperature Control Range4–37°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSwitzerland
TypeFully Automated
ModelSefia™ Automated Cell Expansion System
ComplianceCE-marked (2006/42/EC), IEC 61010, IEC 61326, ICES-001 Class A, China RoHS SJ/T11364-2014
Software ComplianceChronicle™ Viewer validated per GAMP™5 and FDA 21 CFR Part 11
Operating Environment15–25°C, 20–80% RH (non-condensing), 840–1060 mbar, indoor use only, max. altitude 2000 m
ConsumablesSingle-use FEP or silicone-based disposable kits (e.g., Cat. No. 29716713, 29739346)
IntegrationCompatible with Chronicle™ Viewer for audit-trail-enabled data management and real-time process monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginJapan
ModelAmersham ImageQuant 500
Imaging TypeChemiluminescence
CCD Resolution8.3 MP
Dynamic Range4.8 decades
Lens Aperturef/0.14 (Fujifilm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelWave Cellbag
Sterilization MethodGamma Irradiation
Material ComplianceUSP Class VI
Regulatory DocumentationFDA-registered DMF on file
Intended UseResearch, Process Development, cGMP Manufacturing, Cell Therapy Production
Bag ConfigurationSingle-use, pre-sterilized, disposable bioprocess bag
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSwitzerland
ModeliCELLis™ Nano Bioreactor System
Temperature RangeDouble-jacketed with TCU – 20–40 °C
Surface Area Range (iCELLis™ 500+)60–500 m²
Surface Area Range (iCELLis™ Nano)0.53–4 m²
ConfigurationSingle-use, integrated fixed-bed bioreactor
Operating ModesBatch and perfusion
ComplianceDesigned to support GMP-compliant manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelÄKTA™ go
Purification PrincipleGel Filtration Chromatography (GFC)
Gradient TypeLinear Gradient
Flow Rate Range0.01–25 mL/min
Flow Accuracy±2% (at 0.25–25 mL/min, 0.7–3 cP)
Detection OptionsUV monitor (280 nm fixed wavelength), Conductivity monitor (0.01–999.99 mS/cm), pH monitor (range 0–14, accuracy ±0.1 pH units within pH 2–12, ±3°C from calibration temperature)
Pressure Range0–5 MPa
Solvent CompatibilityCompatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning per day
External Detector SupportFluorescence detector, refractive index detector, and other third-party detectors
Show next