| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Model | Amersham DIGE Unit LF24 |
| Gel Dimensions | 255 × 186 × 1 mm |
| External Dimensions | 277 × 217 × 7 mm |
| Max. Simultaneous Gels (Electrophoresis) | 2 |
| Max. Simultaneous Gels (Transfer) | 2 |
| Max. Voltage | 800 V |
| Max. Current | 400 mA |
| Max. Power | 100 W |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan IPGphor 3 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Format Compatibility | IPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm) |
| Sample Capacity | Up to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold |
| Voltage Range | 0–10,000 V (programmable ramping and stepwise control) |
| Current Limit | 0–100 µA–100 mA (auto-adjusting) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Dimensions (W×D×H) | 278 × 160 × 471 mm |
| On-device Method Storage | 10 methods (9 steps each) |
| PC Software Control | Ettan IPGphor 3 Control Software (supports up to 4 instruments simultaneously) |
| Data Logging | Real-time voltage, current, and kV·h monitoring with graphical export |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | TE22 |
| Instrument Type | Wet Protein Electrophoretic Transfer System |
| Gel Capacity | Up to 4 × 9 cm × 10 cm gels per run |
| Cooling System | Integrated aluminum heat exchanger with recirculating buffer cooling |
| Temperature Rise | ≤5°C during standard transfer |
| Buffer Volume Requirement | 1 L per full-load run (4 gels) |
| Cassette Design | Open-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying |
| Compliance | Designed for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan 2D DIGE |
| Instrument Type | Two-Dimensional Fluorescent Differential Gel Electrophoresis System |
| Core Components | Ettan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software |
| Sample Capacity | Up to 3 samples co-separated per 2D gel |
| Sensitivity | Quantitative detection of ≤10% protein abundance change with ≥95% statistical confidence |
| Minimum Sample Requirement | As low as 5 µg total protein per sample |
| Compliance | Designed for GLP-compliant proteomics workflows |