Empowering Scientific Discovery

Cytiva (Cytiva China)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUnited Kingdom
ModelAmersham DIGE Unit LF24
Gel Dimensions255 × 186 × 1 mm
External Dimensions277 × 217 × 7 mm
Max. Simultaneous Gels (Electrophoresis)2
Max. Simultaneous Gels (Transfer)2
Max. Voltage800 V
Max. Current400 mA
Max. Power100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelEttan IPGphor 3
Instrument TypeIsoelectric Focusing (IEF) Electrophoresis System
Gel Format CompatibilityIPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm)
Sample CapacityUp to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold
Voltage Range0–10,000 V (programmable ramping and stepwise control)
Current Limit0–100 µA–100 mA (auto-adjusting)
Temperature Control Range15–30 °C (±0.1 °C stability)
Dimensions (W×D×H)278 × 160 × 471 mm
On-device Method Storage10 methods (9 steps each)
PC Software ControlEttan IPGphor 3 Control Software (supports up to 4 instruments simultaneously)
Data LoggingReal-time voltage, current, and kV·h monitoring with graphical export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelTE22
Instrument TypeWet Protein Electrophoretic Transfer System
Gel CapacityUp to 4 × 9 cm × 10 cm gels per run
Cooling SystemIntegrated aluminum heat exchanger with recirculating buffer cooling
Temperature Rise≤5°C during standard transfer
Buffer Volume Requirement1 L per full-load run (4 gels)
Cassette DesignOpen-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying
ComplianceDesigned for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginSweden
ModelEttan 2D DIGE
Instrument TypeTwo-Dimensional Fluorescent Differential Gel Electrophoresis System
Core ComponentsEttan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software
Sample CapacityUp to 3 samples co-separated per 2D gel
SensitivityQuantitative detection of ≤10% protein abundance change with ≥95% statistical confidence
Minimum Sample RequirementAs low as 5 µg total protein per sample
ComplianceDesigned for GLP-compliant proteomics workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0