BrandCLEAN
OriginTaiwan
ModelCS3523D
Detection ParameterConductivity (single-parameter)
Form FactorPen-type
Conductivity Range0.00–20.00 µS/cm
TDS Range0–10.00 ppm
Resistivity Range0–10.00 MΩ·cm (inferred from low-conductivity context)
Salinity Range0.0–260.0 g/L
Temperature Range−10.0–110.0 °C
Accuracy±0.5% FS
Minimum Resolution0.01 µS/cm
Electrode ConstantK = 0.01 cm⁻¹
Reference Temperature15.0–35.0 °C
Temperature Coefficient0.00–10.00 %/°C
TDS Factor0.40–1.00
Pressure Rating0 to −8 bar (vacuum-rated)
Housing MaterialPolypropylene (PP)
Wetted PartsGlass body, platinum electrodes
ConnectionNPT 3/4″
Cable Length5 m
InterfaceRS-485 Modbus RTU
Power SupplyDC 12 V
Output SignalsConductivity, TDS, Temperature
Ingress ProtectionIP68
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelCON200
PortabilityPortable
Conductivity Range0.000 µS/cm to 400.0 mS/cm
TDS Range0.000 mg/L to 400.0 g/L
Resistivity Range0 to 100.0 MΩ·cm
Salinity Range0.0 to 260.0 g/L
Temperature Range−10.0 °C to 110.0 °C
Accuracy±0.5% of Full Scale
Resolution0.001 µS/cm to 0.1 mS/cm
Display65 × 40 mm backlit LCD
Protection RatingIP67
Data Storage50 readings
PowerTwo AAA batteries (≥500 h lifetime)
Operating Environment−5 °C to 60 °C, <90% RH
Dimensions94 × 190 × 35 mm (W × L × H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelCON500
Form FactorBenchtop
Conductivity Range0.000 µS/cm to 400.0 mS/cm
TDS Range0.000 mg/L to 400.0 g/L
Resistivity Range0 to 100.0 MΩ·cm
Salinity Range0.0 to 260.0 g/L
Temperature Range−10.0 °C to 110.0 °C
Accuracy±0.5% F.S.
Minimum Resolution0.001 µS/cm
Data Storage50 sets
Auto Power-Off10 min (configurable)
IP RatingIP65
Operating Environment−5 °C to 60 °C, <90% RH
Dimensions (W×L×H)140 × 210 × 35 mm
Weight650 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN (USA)
OriginShanghai, China
ModelCON5000
Form FactorBenchtop
ApplicationIndustrial Online Monitoring
Conductivity Range0.000 µS/cm to 400.0 mS/cm
TDS Range0.000 ppm to 400.0 ppt
Resistivity Range0.000 µS/cm to 400.0 mS/cm (inverted calculation)
Salinity Range0.0–260.0 g/L
Temperature Range−10.0–110.0 °C
Accuracy±0.5% FS
Minimum Resolution0.001 µS/cm (low-range), up to 0.1 mS/cm (high-range)
OutputDual 4–20 mA, Isolated RS-485 (Modbus RTU), 3 SPST Relays
Power Supply85–260 VAC or 18–36 VDC (configurable)
Enclosure RatingIP65
Operating Temperature0–60 °C
Display128×64 Dot-Matrix LCD (bilingual: English/Chinese)
Electrode Constants Supported0.01, 0.1, 1.0, 10.0 cm⁻¹
TDS Factor Adjustable0.40–1.00
Temp. CompensationAutomatic (PT1000) or Manual