Empowering Scientific Discovery

Daimai Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelCS1788
pH Range0–14
Temperature Range0–90 °C
Pressure Rating0–20 bar (@50 °C)
Reference SystemSNEX Ag/AgCl/KCl
Liquid JunctionSNEX solid-state membrane with dual ceramic pores
Sensing BulbW02 low-ionic-strength optimized glass
Body MaterialPPS (polyphenylsulfone)
ThreadNPT 3/4"
Cable5 m coaxial, BNC connector
Temperature Sensor OptionsPt1000 / Pt100 / NTC10K
Output4–20 mA (pH/ORP & temperature, 2-wire, passive)
Accuracy±0.01 pH / ±1 mV / ±0.3 °C
Input Impedance≥10¹² Ω
Protection RatingIP65
MountingPanel-mount with dual clamp fixation
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandCLEAN
OriginTaiwan
ModelDH200
Measurement Range (H₂)0.000–2.000 ppm (0–2000 ppb)
Resolution0.001 ppm
Accuracy±0.002 ppm
ORP Range−2000 to +2000 mV
Power2 × AAA batteries
Operating Temp−5 °C to 60 °C
Dimensions94 × 190 × 35 mm (W×L×H)
Weight250 g]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelCS1728D
pH Range0–12
Zero Point7.00 ± 0.25
Resolution0.01 pH
Temperature Range0–80 °C
Max Pressure10 bar
Body MaterialPPS/PP
Sensing MembraneW28 hemispherical glass
Membrane Resistance< 500 MΩ
Reference SystemSNEX Ag/AgCl/KCl solid-state double-junction
Liquid JunctionSNEX dual-salt bridge
Threaded ConnectionNPT 3/4"
Cable Length5 m
Output InterfaceRS-485 Modbus RTU
Supply VoltageDC 12 V
IP RatingIP68
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
ModelCS1778D
OutputRS-485 (Modbus RTU)
pH Range0–14
Temp. Range0–90 °C
Max. Pressure20 bar @ 50 °C
HousingPPS
ThreadNPT 3/4″
Liquid JunctionSNEX solid-state electrolyte membrane
Reference SystemSNEX Ag/AgCl/KCl
Sensing MembraneB11 glass
Temperature SensorPt1000 / Pt100 / NTC10K (field-selectable)
Cable5 m coaxial, BNC termination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelCS1768-hp
Pressure Rating0–20 bar (@ 50 °C)
pH Range0–14
Temperature Range0–90 °C
Liquid JunctionSNEX Solid-State Ag/AgCl/KCl Reference System
Housing MaterialPPS (Polyphenylene Sulfide)
ThreadNPT 3/4″ (wet end & dry end)
Cable5 m coaxial with BNC connector
Temperature Sensor OptionsPt1000 / Pt100 / NTC10K
Output4–20 mA (pH/ORP + temperature, two-wire, passive)
IP RatingIP65
ComplianceDesigned for continuous industrial process monitoring per IEC 61508 functional safety principles (SIL2-capable when integrated with certified controllers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN Instruments
OriginTaiwan
ModelCS1753
ConstructionRugged PPS Body with SNEX Solid-State Junction
Pressure RatingUp to 20 bar (CS1768-hp variant)
Temperature CompensationBuilt-in Pt1000 RTD
Electrolyte SystemDual-ceramic porous junction + red SNEX solid-state liquid junction
Compatible MediaWastewater, seawater, brine, caustic solutions (NaOH/KOH), crude oil emulsions, desulfurization slurry, low-conductivity water (<50 µS/cm), HF-containing streams (<1000 ppm), sulfide-rich environments
Output SignalAnalog mV (pH/ORP) + PT1000 resistance
Electrical GroundingIntegrated shielded grounding terminal
ComplianceDesigned for continuous operation in ISO/IEC 17025-aligned QC labs and EPA-compliant wastewater treatment plants
CertificationsRoHS, CE (EMC Directive 2014/30/EU)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelCS1768
pH Range0–14
Temp. Range0–90 °C
Max. Pressure20 bar (@50 °C)
Junction TypeSNEX Solid-State Ag/AgCl/KCl
Housing MaterialPPS or PA+GF
Temperature SensorPt1000 (standard), Pt100 / NTC10K (optional)
ThreadNPT 3/4" or PG13.5
Cable5 m coaxial with BNC connector
Sensitive Bulb TypeB11
Output CompatibilityDesigned for CLEAN PH3000 transmitter
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0