Empowering Scientific Discovery

Daimai Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelFCL30-R
Instrument TypePortable
Measurement PrincipleElectrochemical Potentiometric Sensor
Measured ParameterFree Residual Chlorine
Range0–2.00 mg/L
Accuracy±1% F.S.
Repeatability±1% F.S.
Resolution0.01 mg/L
LOD0.035 mg/L
Auto Temperature Compensation5.0–45.0 °C
pH Compensation Input Range6.5–8.5
ElectrodeReplaceable CS5931 Free Chlorine Sensor
DisplayBacklit LCD (20 × 30 mm)
Power1 × 1.5 V AAA battery
IP RatingIP67
Dimensions (H×W×D)185 × 40 × 48 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelCS6510NH4
Instrument TypeOnline ISE
Measurement Range0–99,999 mg/L (ppm) NH₄⁺
Detection Limit0–99,999 mg/L (ppm) NH₄⁺
Response Time≤30 s to 95% of final value
Accuracy±2.5% of reading
Operating Temperature Range–10 °C to +150 °C
pH Range for Measurement4–10
Reference ElectrodeDual-salt-bridge with annular ceramic junction
Body MaterialGlass
DimensionsØ12 × 110 mm
Cable Length1 m
ConnectorBNC
Output Impedance≥100 MΩ
Temperature CompensationIntegrated
Pressure RatingNot specified
InterferenceK⁺ (significant), other monovalent cations (moderate)
StorageLong-term — dry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelCS4751D
Instrument TypeOnline
Measurement PrincipleElectrochemical (Clark-type Polarographic Probe)
Range0.0–400.0% saturation, 0.00–40.00 mg/L
Accuracy±0.2% FS
Repeatability0.1% / 0.01 mg/L
Detection Limit±2 ppb (zero point)
Temperature Range (Operating)0–60 °C
Temperature Measurement Range−10.0–110.0 °C
Temp. Resolution0.1 °C
Salinity Compensation0.0–50.0 ppt
Pressure Compensation600–2000 mbar
Response Time (t₉₅)<60 s at 25 °C
Stabilization Time15–20 min
Zero Drift<0.5% FS
Housing MaterialPPS/PP
Electrode Cap ThreadNPT 3/4″
Cable Length5 m
ConnectorOpen-terminal block
Communication InterfaceRS-485
ProtocolModbus RTU
Power SupplyDC 12 V
Output SignalsDO concentration (mg/L and % sat), temperature
IP RatingIP68
Minimum Flow Rate>0.03 m/s
Residual Current<2% in air
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelORP30
Instrument TypePortable/Handheld Water Quality Analyzer
ORP Range−900 to +900 mV
ORP Resolution1 mV
ORP Accuracy±1 mV
Temperature Range0.0–100.0 °C (32–212 °F)
Temperature Resolution0.1 °C / 1 °F
CalibrationTwo-point using standard solutions (86 mV and 255 mV)
ElectrodeReplaceable CS2930 platinum disc planar ORP electrode
DisplayMulti-line LCD (21 × 34 mm) with auto-backlight
Ingress ProtectionIP67
Auto-power-off5 minutes of inactivity
Power1 × 1.5 V AAA battery
Dimensions (H×W×D)185 × 40 × 48 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelDOZ30
Measurement PrincipleThree-Electrode Amperometric
Range0–10.00 ppm
Resolution0.01 ppm
Accuracy±1% F.S.
Temperature Range0.0–100.0°C
CalibrationTwo-point (zero + user-defined point)
ElectrodeReplaceable CS6930 Dissolved Ozone Sensor
IP RatingIP67
DisplayBacklit 20×30 mm LCD, multi-line
Auto-off5 min idle
Power1×1.5 V AAA battery
Dimensions185×40×48 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelDO30
Instrument TypePortable
Measurement PrincipleGalvanic Cell Electrochemical Probe
Measurement Range0.00–40.00 mg/L (ppm) and 0.0–200.0% saturation
Accuracy±2% of full scale
Resolution0.01 mg/L, 0.1% saturation
Temperature Range0–100.0 °C (32–212 °F)
Temperature CompensationAutomatic (0–60 °C)
Salinity Compensation0.0–40.0 ppt
Atmospheric Pressure Compensation600–1100 mbar
Calibration1- or 2-point (zero-oxygen solution or air-saturated water)
DisplayMulti-line LCD (21 × 34 mm), backlight enabled
IP RatingIP67
Power1 × 1.5 V AAA battery
Dimensions (H×W×D)185 × 40 × 48 mm
Weight95 g
Auto-off5 minutes of inactivity
Electrode ReplaceabilityUser-serviceable galvanic probe with replaceable membrane cap (CS49303H1L)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCON30
Instrument TypeBenchtop & Field-Portable Water Quality Analyzer
Price RangeUSD 280 – 1,400 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFluoride ISE (CS00F02)
Instrument TypeFluoride Ion Selective Electrode
Measurement Range0.02 ppm to saturation
ComplianceASTM D1129, ISO 10523, USP <771>, EPA Method 300.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginShanghai, China
ModelCS6510Cl
Instrument TypeOnline ISE Sensor
Measurement Range0–99,999 mg/L (ppm) Cl⁻
Detection Limits0.01 / 0.1 / 1 mg/L (ppm)
Response Time30 s (to 95% signal stability)
Accuracy±2.5% of reading
Operating Temperature0–50 °C
Output InterfaceBNC
Body MaterialGlass
DimensionsØ12 × 110 mm
Reference SystemDouble-junction Ag/AgCl with annular ceramic frit
InterferentsS²⁻, I⁻, CN⁻, Br⁻
pH Range2–12
Input Impedance<1 MΩ
Temperature CompensationNot recommended for direct electrode compensation
StorageLong-term—dry
Electrode Slope56 ± 3 mV/decade at 25 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelDO200
Instrument TypePortable
Measurement PrincipleGalvanic Cell Electrochemical Probe
DO Range0.00–40.00 mg/L
Saturation Range0.0–400.0%
DO Resolution0.01 mg/L
Saturation Resolution0.1%
DO Accuracy±0.2% F.S.
Temperature Range0.0–50.0 °C
Temperature Accuracy±0.2 °C
Temperature Resolution0.1 °C
Atmospheric Pressure Setting600–1400 mbar (1 mbar step)
Salinity Setting0.0–40.0 g/L (0.1 g/L step)
Data Storage50 sets
IP RatingIP67
Dimensions94 × 190 × 35 mm (W × L × H)
Power2 × AAA batteries (>500 hrs operation)
Operating Environment−5 to 60 °C, <90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCS00NH301
PricingAvailable Upon Request
Measurement Range0.01–17,000 ppm
Slope56 ± 3 mV/decade at 25 °C
Repeatability±2%
Response Time≤30 s to 95% of final value
Operating Temperature0–50 °C
Pressure Rating0–30 psi
pH Compatibility>11
InterferentsVolatile amines
Housing MaterialEpoxy resin
Dimensions12 × 110 mm
Cable Length1 m
ConnectorBNC
MembraneReplaceable
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelS400-RT330-M10BC
Instrument TypeOnline Water Quality Analyzer
pH Range0–14
Temperature Range0–105 °C
Max. Pressure150 psig (10 bar) at 100 °C
Max. Flow Rate3 m/s
Reference SystemAg/AgCl
Salt BridgeDual-compartment
Liquid-contact MaterialsRyton (PPS), PTFE, HT-3 blue glass
Sensing MembraneHT-3 borosilicate glass bulb
Output Impedance< 250 MΩ at 25 °C
Process Connection3/4" NPT male thread
Cable3 m, 5 mm OD, BNC termination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginShanghai, China
ModelCS6510F
Instrument TypeOnline ISE Probe
Measurement Range0–99,999 mg/L (ppm) F⁻
Detection Limits0.01 / 0.1 / 1 mg/L (ppm)
Response Time30 s (to 95% signal stability)
Accuracy±2.5% of reading
Operating Temperature0–50 °C
pH Range5–8
Temperature CompensationIntegrated
Reference ElectrodeDouble-junction, annular ceramic junction
Body MaterialGlass
DimensionsØ12 × 110 mm
ConnectorBNC
Pressure Rating0–70 psi
Interface CompatibilityCompatible with pH meters, ion meters, and online ion analyzers (e.g., ION5000 series)
InterferencesAl³⁺, Fe³⁺ (requires masking agents or pH control)
StorageLong-term—dry
Electrode Slope57 ± 2 mV/decade at 25 °C
Input Impedance100–200 kΩ
Equivalence Point20 ppm F⁻ (for potentiometric titration support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
ModelCS5530D
Instrument TypeOnline
Measurement PrincipleAmperometric Electrochemical Sensor
Measured ParameterFree Chlorine (Residual Cl₂)
Range0–2.000 mg/L and 0–20.00 mg/L
Accuracy≤3% of reading
Repeatability±0.02 mg/L
Resolution0.001 mg/L (low range), 0.01 mg/L (high range)
LOD0.035 mg/L
Temperature CompensationIntegrated Pt1000 RTD
pH CompensationBuilt-in pH input interface for external pH electrode integration
Operating Temperature0–80 °C
Max Pressure10 bar
Housing MaterialGlass sensing element + PP + POM
Reference SystemDual-salt-bridge Ag/AgCl
Junction TypeAnnular ceramic liquid junction
Cap MaterialPP
ConnectorPG13.5
Handle MaterialPOM
Cable Length5 m
CommunicationRS-485 Modbus RTU
Power SupplyDC 12 V
Output SignalsResidual chlorine concentration (mg/L), temperature (°C)
Enclosure RatingIP68
Compatible Flow CellA580 hermetically sealed flow-through cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN (USA)
OriginShanghai, China
ModelFCL5000
Instrument TypeOnline Analyzer
Measurement PrincipleAmperometric Electrochemical Sensor (Three-Electrode Constant-Voltage Method, Membrane-Free)
Measured ParameterFree Chlorine (HOCl/OCl⁻)
Range0.000–2.000 ppm and 0.00–20.00 ppm (dual-range auto-switching)
Accuracy±2% of full scale
Resolution0.001 ppm
Detection Limit0.000 ppm
pH Compensation Range4.00–9.00 pH (nonlinear, automatic)
pH Input Range0.00–14.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH
Temperature Range−10.0–130.0 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.3 °C
OutputDual isolated 4–20 mA (±1% FS, load < 500 Ω)
CommunicationRS-485 with optical isolation, MODBUS RTU protocol
Relay OutputsTwo SPST control relays (2.5 A / 230 VAC) + one configurable function relay
Power Supply85–260 VAC or optional 24 VDC
Enclosure RatingIP65
Operating Environment0–60 °C, RH < 90% non-condensing
MountingPanel mount (cutout: 92.5 × 92.5 mm)
Dimensions (H×W×D)108 × 108 × 128 mm
Calibration MethodDPD colorimetric verification compatible
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelE-1312-EC1-M10ST
Instrument TypeOnline Water Quality Analyzer
Operating Temperature−5 to 100 °C
pH Range0.00–14.00
Max Pressure Rating30 psig
Junction TypeAnnular Ceramic Junction
Reference SystemAg/AgCl Dual-Salt-Bridge
Fill SolutionNon-refillable, Internal-Pressure 3.8 M KCl
Sensing ElementHT-3 UV-Resistant Blue Glass Membrane
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelCS6710Ca
Instrument TypeOnline-Ready ISE
Measurement Range0.1–18,000 ppm NH₄⁺
Detection Limit0.1 ppm NH₄⁺
Response Time≤30 s to 95% of final signal
Output Sensitivity55 ± 3 mV/decade
Operating Temperature0–50 °C
pH Range for Measurement4–10
Input Impedance20–50 MΩ
Reference SystemDouble-junction Ag/AgCl with single-pore ceramic junction
Body MaterialPMMA + PVC
Threaded ConnectionPG13.5 / NPT 3/4″
Cable Length5 m
Pressure Rating0–2 atm
Temperature Compensation Options10 kΩ, 22 kΩ, PT100, or PT1000 thermistors
Zero Point Calibration10 ppm NH₄⁺ isopotential point
InterferenceK⁺ (significant), Na⁺ (minor), Ca²⁺/Mg²⁺ (negligible at pH 4–10)
StorageLong-term — dry
Compatible InstrumentsBenchtop ion meters, pH/mV meters with millivolt input, and OEM online ammonia analyzers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelFCL30
Instrument TypePortable
Measurement PrincipleAmperometric (Tri-Electrode)
Measured ParameterFree Residual Chlorine
Range0–10.00 ppm
Accuracy±1% F.S.
Repeatability±1% F.S.
Resolution0.01 ppm
Detection Limit0 ppm
Temperature Range0.0–100.0°C
Calibration2-point (zero + span)
Data Storage10 readings
Enclosure RatingIP67
DisplayMulti-line LCD (21 × 34 mm), auto-backlit
Power1 × 1.5 V AAA battery
Dimensions (H×W×D)185 × 40 × 48 mm
Weight95 g
ElectrodeReplaceable CS5930 amperometric tri-electrode sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginTaiwan
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China Market Distribution)
ModelDH30
PriceUSD 285 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelCPB401BT
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN
OriginUSA
ModelDO500
Instrument TypeLaboratory Benchtop
Measurement PrincipleGalvanic Cell Electrochemical Probe
Measurement Range (DO)0.00–40.00 mg/L
Accuracy±0.2% F.S.
Repeatability0.1%
Detection Limit0 mg/L
Saturation Range0.0–400.0%
Temperature Compensation Range0.0–50.0 °C
Temp. Accuracy±0.2 °C
Atmospheric Pressure Setting600–1400 mbar (1 mbar resolution)
Salinity Compensation0.0–40.0 g/L (0.1 g/L resolution)
Data Storage50 sets
Dimensions140 × 210 × 35 mm (W × L × H)
Weight650 g
Operating Environment–5 to 60 °C, <90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCLEAN (USA)
OriginUSA
ModelDO5000
Instrument TypeOnline DO Controller
Measurement PrinciplePolarographic Electrochemical Probe
Measurement Range0.0–400.0 % saturation, 0.00–40.00 mg/L
Accuracy±0.1 % FS, ±0.01 mg/L
Repeatability±0.2 % FS
Detection Limit0.0–40.0 ppt
Display128×64 dot-matrix LCD (English/Chinese switchable)
IP RatingIP65
OutputDual isolated 4–20 mA (configurable), RS-485 with opto-isolation
Communication ProtocolMODBUS RTU
Relay Outputs2 × SPST control relays (2.5 A / 230 VAC), 1 × user-configurable function relay (e.g., cleaning or alarm)
Temperature CompensationAutomatic/manual (with TH22k sensor input)
Pressure & Salinity CompensationManual
Power Supply85–260 VAC or 24 VDC (user-selectable)
Operating Temp.0–60 °C
Humidity<90 % RH (non-condensing)
MountingPanel-mount
Dimensions (H×W×D)108×108×128 mm
Cutout92.5×92.5 mm (positive tolerance)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTaiwan
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelPH30P
Price RangeUSD 140–420
pH Range0.00–13.00
pH Resolution0.01 pH
pH Accuracy±0.01 + 1 LSD
Temperature Range0–100.0 °C
Temperature Resolution0.1 °C
ElectrodeReplaceable CS1930P Piercing-Type pH Sensor (316L stainless steel shaft)
DisplayBacklit 20×30 mm multi-line LCD
Battery1×1.5 V AAA (>500 h life)
Auto-off5 min
Dimensions185×40×48 mm
Weight95 g