- All
- Favorite
- Popular
- Most rated
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CS6510NH4 |
| Instrument Type | Online ISE |
| Measurement Range | 0–99,999 mg/L (ppm) NH₄⁺ |
| Detection Limit | 0–99,999 mg/L (ppm) NH₄⁺ |
| Response Time | ≤30 s to 95% of final value |
| Accuracy | ±2.5% of reading |
| Operating Temperature Range | –10 °C to +150 °C |
| pH Range for Measurement | 4–10 |
| Reference Electrode | Dual-salt-bridge with annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Cable Length | 1 m |
| Connector | BNC |
| Output Impedance | ≥100 MΩ |
| Temperature Compensation | Integrated |
| Pressure Rating | Not specified |
| Interference | K⁺ (significant), other monovalent cations (moderate) |
| Storage | Long-term — dry |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluoride ISE (CS00F02) |
| Instrument Type | Fluoride Ion Selective Electrode |
| Measurement Range | 0.02 ppm to saturation |
| Compliance | ASTM D1129, ISO 10523, USP <771>, EPA Method 300.0 |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510Cl |
| Instrument Type | Online ISE Sensor |
| Measurement Range | 0–99,999 mg/L (ppm) Cl⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| Output Interface | BNC |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Reference System | Double-junction Ag/AgCl with annular ceramic frit |
| Interferents | S²⁻, I⁻, CN⁻, Br⁻ |
| pH Range | 2–12 |
| Input Impedance | <1 MΩ |
| Temperature Compensation | Not recommended for direct electrode compensation |
| Storage | Long-term—dry |
| Electrode Slope | 56 ± 3 mV/decade at 25 °C |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510F |
| Instrument Type | Online ISE Probe |
| Measurement Range | 0–99,999 mg/L (ppm) F⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| pH Range | 5–8 |
| Temperature Compensation | Integrated |
| Reference Electrode | Double-junction, annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Connector | BNC |
| Pressure Rating | 0–70 psi |
| Interface Compatibility | Compatible with pH meters, ion meters, and online ion analyzers (e.g., ION5000 series) |
| Interferences | Al³⁺, Fe³⁺ (requires masking agents or pH control) |
| Storage | Long-term—dry |
| Electrode Slope | 57 ± 2 mV/decade at 25 °C |
| Input Impedance | 100–200 kΩ |
| Equivalence Point | 20 ppm F⁻ (for potentiometric titration support) |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CS6710Ca |
| Instrument Type | Online-Ready ISE |
| Measurement Range | 0.1–18,000 ppm NH₄⁺ |
| Detection Limit | 0.1 ppm NH₄⁺ |
| Response Time | ≤30 s to 95% of final signal |
| Output Sensitivity | 55 ± 3 mV/decade |
| Operating Temperature | 0–50 °C |
| pH Range for Measurement | 4–10 |
| Input Impedance | 20–50 MΩ |
| Reference System | Double-junction Ag/AgCl with single-pore ceramic junction |
| Body Material | PMMA + PVC |
| Threaded Connection | PG13.5 / NPT 3/4″ |
| Cable Length | 5 m |
| Pressure Rating | 0–2 atm |
| Temperature Compensation Options | 10 kΩ, 22 kΩ, PT100, or PT1000 thermistors |
| Zero Point Calibration | 10 ppm NH₄⁺ isopotential point |
| Interference | K⁺ (significant), Na⁺ (minor), Ca²⁺/Mg²⁺ (negligible at pH 4–10) |
| Storage | Long-term — dry |
| Compatible Instruments | Benchtop ion meters, pH/mV meters with millivolt input, and OEM online ammonia analyzers |
Show next